CoChat

3D interfractional patient position verification using 2D‐3D registration of orthogonal images

Jans, H.‐S., Syme, A. M., Rathee, S., Fallone, B. G. · 2006 · Medical Physics
Cited by 36

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Reproducible positioning of the patient during fractionated external beam radiation therapy is imperative to ensure that the delivered dose distribution matches the planned one. In this paper, we expand on a 2D‐3D image registration method to verify a patient's setup in three dimensions (rotations and translations) using orthogonal portal images and megavoltage digitally reconstructed radiographs (MDRRs) derived from CT data. The accuracy of 2D‐3D registration was improved by employing additional image preprocessing steps and a parabolic fit to interpolate the parameter space of the cost function utilized for registration. Using a humanoid phantom, precision for registration of three‐dimensional translations was found to be better than (1 s.d.) for any axis when no rotations were present. Three‐dimensional rotations about any axis were registered with a precision of better than (1 s.d.) when no translations were present. Combined rotations and translations of up to and were registered with and accuracy for each axis. The influence of setup translations on registration of rotations and vice versa was also investigated and mostly agrees with a simple geometric model. Additionally, the dependence of registration accuracy on three cost functions, angular spacing between MDRRs, pixel size, and field‐of‐view, was examined. Best results were achieved by mutual information using angular spacing and a field‐of‐view with . Approximating patient motion as rigid transformation, the registration method is applied to two treatment plans and the patients’ setup errors are determined. Their magnitude was found to be and for any axis in all of the six fractions measured for each treatment plan.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2192907

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 36

Metadata

Authors
Jans, H. ‐., Syme, A. M., Rathee, S., & Fallone, B. G.
Venue
Medical Physics
Publisher
Wiley
Published
2006-04-27
Volume
33
Issue
5
Pages
1420-1439
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2045215677
Cited by
36
References
2
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.