The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
An outlook on x‐ray CT research and development
Abstract
Over the past decade, computed tomography(CT) theory, techniques and applications have undergone a rapid development. Since CT is so practical and useful, undoubtedly CT technology will continue advancing biomedical and non‐biomedical applications. In this outlook article, we share our opinions on the research and development in this field, emphasizing 12 topics we expect to be critical in the next decade: analytic reconstruction, iterative reconstruction, local/interior reconstruction, flat‐panel based CT, dual‐source CT, multi‐source CT, novel scanning modes, energy‐sensitive CT, nano‐CT, artifact reduction, modality fusion, and phase‐contrast CT. We also sketch several representative biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Cited by
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution
Zhang, Z., Liang, X., Dong, X., Xie, Y., & Cao, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823338 · Cited by 447
Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
Gold Nanoparticles as Contrast Agents in x-ray Imaging and Computed Tomography
Cole, L. E., Ross, R. D., Tilley, J. M., Vargo-Gogola, T., & Roeder, R. K. (2015) · Nanomedicine · doi:10.2217/nnm.14.171 · Cited by 356
Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2058811 · Cited by 290
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction
Liu, J., Anirudh, R., Thiagarajan, J. J., He, S., Mohan, K. A., Kamilov, U. S., & Kim, H. (2023) · 2023 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.00963 · Cited by 106
“The x-rays get attenuated as they propagate through the object and the intensity of attenuated x-rays exiting the object is measured by the detector.”
BackgroundParallel CT image reconstruction based on GPUs
Flores, L. A., Vidal, V., Mayo, P., Rodenas, F., & Verdú, G. (2014) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2013.03.011 · Cited by 28
CT Image Reconstruction Based on GPUs
Flores, L. A., Vidal, V., Mayo, P., Rodenas, F., & Verdú, G. (2013) · Procedia Computer Science · doi:10.1016/j.procs.2013.05.308 · Cited by 16
SIFT algorithm-based 3D pose estimation of femur
Zhang, X., Zhu, Y., Li, C., Zhao, J., & Li, G. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141103 · Cited by 8
Metadata
- Authors
- Wang, G., Yu, H., & De Man, B.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-02-25
- Volume
- 35
- Issue
- 3
- Pages
- 1051-1064
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2086197330
- Cited by
- 341
- References
- 48
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.