The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
An outlook on x‐ray CT research and development
Abstract
Over the past decade, computed tomography(CT) theory, techniques and applications have undergone a rapid development. Since CT is so practical and useful, undoubtedly CT technology will continue advancing biomedical and non‐biomedical applications. In this outlook article, we share our opinions on the research and development in this field, emphasizing 12 topics we expect to be critical in the next decade: analytic reconstruction, iterative reconstruction, local/interior reconstruction, flat‐panel based CT, dual‐source CT, multi‐source CT, novel scanning modes, energy‐sensitive CT, nano‐CT, artifact reduction, modality fusion, and phase‐contrast CT. We also sketch several representative biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
The Mathematics of Computerized Tomography
Natterer, F. (2001) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719284 · Cited by 1,047
Digital tomosynthesis in breast imaging.
Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., et al. (1997) · Radiology · doi:10.1148/radiology.205.2.9356620 · Cited by 763
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Recent Advances in X-ray Phase Imaging
Momose, A. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.6355 · Cited by 556
Optimal short scan convolution reconstruction for fan beam CT
Parker, D. L. (1982) · Medical Physics · doi:10.1118/1.595078 · Cited by 525
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
Self-citationNational Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Micro-CT in small animal and specimen imaging
Holdsworth, D. W., & Thornton, M. M. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)02004-8 · Cited by 334
A general cone-beam reconstruction algorithm
Wang, G., Lin, T.-H., Cheng, P., & Shinozaki, D. M. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241876 · Cited by 333
Self-citationUniqueness theorems in bioluminescence tomography
Wang, G., Li, Y., & Jiang, M. F. (2004) · Medical Physics · doi:10.1118/1.1766420 · Cited by 292
Self-citationIterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Algorithm for image reconstruction in multi-slice helical CT
Taguchi, K., & Aradate, H. (1998) · Medical Physics · doi:10.1118/1.598230 · Cited by 286
Cone‐beam volume CT breast imaging: Feasibility study
Chen, B., & Ning, R. (2002) · Medical Physics · doi:10.1118/1.1461843 · Cited by 277
Statistical Image Reconstruction Methods for Transmission Tomography
Fessler, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch1 · Cited by 240
Kiessling, F., Greschus, S., Lichy, M. P., Bock, M., Fink, C., Vosseler, S., Moll, J., Mueller, M. M., Fusenig, N. E., Traupe, H., et al. (2004) · Nature Medicine · doi:10.1038/nm1101 · Cited by 205
A General Local Reconstruction Approach Based on a Truncated Hilbert Transform
Ye, Y., Yu, H., Wei, Y., & Wang, G. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/63634 · Cited by 176
Self-citationBoas, D. A., & Dale, A. M. (2005) · Applied Optics · doi:10.1364/ao.44.001957 · Cited by 152
Computed Tomography for Imaging the Breast
Boone, J. M., Kwan, A. L. C., Yang, K., et al. (2006) · Journal of Mammary Gland Biology and Neoplasia · doi:10.1007/s10911-006-9017-1 · Cited by 150
Paulus, M. J., Gleason, S. S., Easterly, M. E., & Foltz, C. J. (2001) · PubMed · Cited by 146
Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction
Wang, G., Vannier, M. W., & Cheng, P. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699000057 · Cited by 140
Self-citationElbakri, I. A., & Fessler, J. A. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/314 · Cited by 137
Zhuang, T., Leng, S., Nett, B. E., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/24/007 · Cited by 108
Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image Registration
Zeng, R., Fessler, J. A., & Balter, J. M. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.889719 · Cited by 93
Kalra, M. K., Naz, N., Rizzo, S., & Blake, M. A. (2005) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2005.06.002 · Cited by 92
Clarification of aspects in in‐line phase‐sensitive x‐ray imaging
Wu, X., & Liu, H. (2007) · Medical Physics · doi:10.1118/1.2431475 · Cited by 72
Respiratory motion estimation from slowly rotating x‐ray projections: Theory and simulation
Zeng, R., Fessler, J. A., & Balter, J. M. (2005) · Medical Physics · doi:10.1118/1.1879132 · Cited by 64
Kinahan, P. E., Alessio, A. M., & Fessler, J. A. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500403 · Cited by 63
Design and performance characteristics of a digital flat-panel computed tomography system
Ross, W., CODY, D. D., & Hazle, J. D. (2006) · Medical Physics · doi:10.1118/1.2198941 · Cited by 56
A knowledge‐based cone‐beam x‐ray CT algorithm for dynamic volumetric cardiac imaging
Wang, G., Zhao, S., & Heuscher, D. J. (2002) · Medical Physics · doi:10.1118/1.1494989 · Cited by 42
Self-citationTang, X., & Hsieh, J. (2004) · Medical Physics · doi:10.1118/1.1803672 · Cited by 35
2005 IEEE Nuclear Science Symposium - Conference Record
(2005) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2005.1596186 · Cited by 32
Cited by
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution
Zhang, Z., Liang, X., Dong, X., Xie, Y., & Cao, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823338 · Cited by 447
Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
Metadata
- Authors
- Wang, G., Yu, H., & De Man, B.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-02-25
- Volume
- 35
- Issue
- 3
- Pages
- 1051-1064
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2086197330
- Cited by
- 341
- References
- 48
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.