The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Prospects of photoacoustic tomography
Open accessAbstract
Commercially available high‐resolution three‐dimensional optical imaging modalities—including confocal microscopy, two‐photon microscopy, and optical coherence tomography—have fundamentally impacted biomedicine. Unfortunately, such tools cannot penetrate biological tissue deeper than the optical transport mean free path( in the skin). Photoacoustic tomography, which combines strong optical contrast and high ultrasonic resolution in a single modality, has broken through this fundamental depth limitation and achieved superdepth high‐resolution optical imaging. In parallel, radio frequency‐or microwave‐induced thermoacoustic tomography is being actively developed to combine radio frequency or microwave contrast with ultrasonic resolution. In this Vision article, the prospects of photoacoustic tomography are envisaged in the following aspects: (1) photoacoustic microscopy of optical absorption emerging as a mainstream technology, (2) melanoma detection using photoacoustic microscopy, (3) photoacoustic endoscopy, (4) simultaneous functional and molecular photoacoustic tomography, (5) photoacoustic tomography of gene expression, (6) Doppler photoacoustic tomography for flow measurement, (7) photoacoustic tomography of metabolic rate of oxygen, (8) photoacoustic mapping of sentinel lymph nodes, (9) multiscale photoacoustic imaging in vivo with common signal origins, (10) simultaneous photoacoustic and thermoacoustic tomography of the breast, (11) photoacoustic and thermoacoustic tomography of the brain, and (12) low‐background thermoacoustic molecular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationUniversal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationAdvances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Self-citationTutorial on Photoacoustic Microscopy and Computed Tomography
Wang, L. V. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913398 · Cited by 607
Self-citationTime-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Self-citationThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
In vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413
Self-citationDetermining a Function from Its Mean Values Over a Family of Spheres
Finch, D., & Patch, S. K. (2004) · SIAM Journal on Mathematical Analysis · doi:10.1137/s0036141002417814 · Cited by 410
Li, M.-L., Oh, J.-T., Xie, X., Ku, G., Wang, W., Li, C., Lungu, G., Stoica, G., & Wang, L. V. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.913515 · Cited by 352
Self-citationIterative reconstruction algorithm for optoacoustic imaging
Paltauf, G., Viator, J. A., Prahl, S. A., & Jacques, S. L. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1501898 · Cited by 269
Cox, B. T., Arridge, S. R., Köstli, K. P., & Beard, P. C. (2006) · Applied Optics · doi:10.1364/ao.45.001866 · Cited by 256
Song, K. H., Stein, E. W., Margenthaler, J. A., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976427 · Cited by 225
Self-citationImaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography
Ku, G., Wang, X., Xie, X., Stoica, G., & Wang, L. V. (2005) · Applied Optics · doi:10.1364/ao.44.000770 · Cited by 219
Self-citationPhotoacoustic imaging of lacZ gene expression in vivo
Li, L., Zemp, R. J., Lungu, G., Stoica, G., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717531 · Cited by 187
Self-citationDeep reflection-mode photoacoustic imaging of biological tissue
Song, K. H., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2818045 · Cited by 181
Self-citationCan the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/311 · Cited by 175
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Self-citationThermoacoustic and Photoacoustic Tomography of Thick Biological Tissues toward Breast Imaging
Ku, G., Fornage, B. D., Jin, X., Xu, M., Hunt, K. K., & Wang, L. V. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400509 · Cited by 170
Self-citationDetection of ultrawide-band ultrasound pulses in optoacoustic tomography
Андреев, В. Г., Karabutov, A. A., & Oraevsky, A. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244756 · Cited by 131
Rhesus monkey brain imaging through intact skull with thermoacoustic tomography
Xu, Y., & Wang, L. V. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1610562 · Cited by 127
Self-citationPhotoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer
Zemp, R. J., Bitton, R. R., Shung, K. K., Li, M.-L., Stoica, G., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2709850 · Cited by 113
Self-citationOptoacoustic imaging using a three-dimensional reconstruction algorithm
Köstli, K. P., Frauchiger, D., Niederhauser, J. J., Paltauf, G., Weber, H. P., & Frenz, M. (2001) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.983294 · Cited by 111
Photoacoustic Doppler Flow Measurement in Optically Scattering Media
Fang, H., Maslov, K., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2825569 · Cited by 64
Self-citation
Cited by
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Khlebtsov, N., & Dykman, L. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00018c · Cited by 1,584
Nanomaterials as photothermal therapeutic agents
Chen, J., Ning, C., Zhou, Z., Yu, P., Zhu, Y., Tan, G., & Mao, C. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2018.07.005 · Cited by 749
Photoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
PHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Self-citation
Metadata
- Authors
- Wang, L. V.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-11-19
- Volume
- 35
- Issue
- 12
- Pages
- 5758-5767
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2085564184
- Cited by
- 561
- References
- 29
- FWCI
- 23.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.