2D‐3D registration for prostate radiation therapy based on a statistical model of transmission images
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: In external beam radiation therapy of pelvic sites, patient setup errors can be quantified by registering 2D projection radiographs acquired during treatment to a 3D planning computed tomograph (CT). We present a 2D‐3D registration framework based on a statistical model of the intensity values in the two imaging modalities. Methods: The model assumes that intensity values in projection radiographs are independently but not identically distributed due to the nonstationary nature of photon counting noise. Two probability distributions are considered for the intensity values: Poisson and Gaussian. Using maximum likelihood estimation, two similarity measures, maximum likelihood with a Poisson (MLP) and maximum likelihood with Gaussian (MLG), distribution are derived. Further, we investigate the merit of the model‐based registration approach for data obtained with current imaging equipment and doses by comparing the performance of the similarity measures derived to that of the Pearson correlation coefficient (ICC) on accurately collected data of an anthropomorphic phantom of the pelvis and on patient data. Results: Registration accuracy was similar for all three similarity measures and surpassed current clinical requirements of for pelvic sites. For pose determination experiments with a kilovoltage (kV) cone‐beam CT (CBCT) and kV projection radiographs of the phantom in the anterior‐posterior (AP) view, registration accuracies were (MLP), (MLG), and (ICC). For kV CBCT and megavoltage (MV) AP portal images of the same phantom, registration accuracies were (MLP), (MLG), and (ICC). Registration of a kV CT and MV AP portal images of a patient was successful in all instances. Conclusions: The results indicate that high registration accuracy is achievable with multiple methods including methods that are based on a statistical model of a 3D CT and 2D projection images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
Otake, Y., Schafer, S., Stayman, J. W., Zbijewski, W., Kleinszig, G., Graumann, R., Khanna, A. J., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5485 · Cited by 79
A Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy
Liao, R., Zhang, L., Sun, Y., Miao, S., & Chefd'Hotel, C. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244869 · Cited by 71
3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
Otake, Y., Wang, A. S., Uneri, A., Kleinszig, G., Vogt, S., Aygun, N., Lo, S.-F. L., Wolinsky, J.-P., Gokaslan, Z. L., & Siewerdsen, J. H. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/5/2075 · Cited by 41
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Metadata
- Authors
- Munbodh, R., Tagare, H. D., Chen, Z., Jaffray, D. A., Moseley, D. J., Knisely, J. P. S., & Duncan, J. S.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-09-11
- Volume
- 36
- Issue
- 10
- Pages
- 4555-4568
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2058004921
- Cited by
- 22
- References
- 1
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.