Multiresolution MR elastography using nonlinear inversion
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Purpose: Nonlinear inversion (NLI) in MR elastography requires discretization of the displacement field for a finite element (FE) solution of the “forward problem”, and discretization of the unknown mechanical property field for the iterative solution of the “inverse problem”. The resolution requirements for these two discretizations are different: the forward problem requires sufficient resolution of the displacement FE mesh to ensure convergence, whereas lowering the mechanical property resolution in the inverse problem stabilizes the mechanical property estimates in the presence of measurement noise. Previous NLI implementations use the same FE mesh to support the displacement and property fields, requiring a trade‐off between the competing resolution requirements. Methods: This work implements and evaluates multiresolution FE meshes for NLI elastography, allowing independent discretizations of the displacements and each mechanical property parameter to be estimated. The displacement resolution can then be selected to ensure mesh convergence, and the resolution of the property meshes can be independently manipulated to control the stability of the inversion. Results: Phantom experiments indicate that eight nodes per wavelength (NPW) are sufficient for accurate mechanical property recovery, whereas mechanical property estimation from 50 Hz in vivo brain data stabilizes once the displacement resolution reaches 1.7 mm (approximately 19 NPW). Viscoelastic mechanical property estimates of in vivo brain tissue show that subsampling the loss modulus while holding the storage modulus resolution constant does not substantially alter the storage modulus images. Controlling the ratio of the number of measurements to unknown mechanical properties by subsampling the mechanical property distributions (relative to the data resolution) improves the repeatability of the property estimates, at a cost of modestly decreased spatial resolution. Conclusions: Multiresolution NLI elastography provides a more flexible framework for mechanical property estimation compared to previous single mesh implementations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
The impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Oliphant, T. E., Manduca, A., Ehman, R. L., & Greenleaf, J. F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<299::aid-mrm1039>3.0.co;2-o · Cited by 411
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastography
Murphy, M. C., Huston, J., Jack, C. R., Glaser, K. J., Manduca, A., Felmlee, J. P., & Ehman, R. L. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22707 · Cited by 348
Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21404 · Cited by 332
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
MR-elastography reveals degradation of tissue integrity in multiple sclerosis
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., & Sack, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.018 · Cited by 309
An overlapping subzone technique for MR-based elastic property reconstruction
Van Houten, E. E. W., Paulsen, K. D., Miga, M. I., Kennedy, F. E., & Weaver, J. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4<779::aid-mrm21>3.0.co;2-z · Cited by 214
Self-citationThree‐dimensional subzone‐based reconstruction algorithm for MR elastography
Van Houten, E. E. W., Miga, M. I., Weaver, J. B., Kennedy, F. E., & Paulsen, K. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1111 · Cited by 179
Self-citationIn vivo viscoelastic properties of the brain in normal pressure hydrocephalus
Streitberger, K., Wiener, E., Hoffmann, J., Freimann, F. B., Klatt, D., Braun, J., Lin, K., McLaughlin, J., Sprung, C., Klingebiel, R., et al. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1602 · Cited by 171
An octahedral shear strain-based measure of SNR for 3D MR elastography
McGarry, M., Houten, E. E. W. V., Perriñez, P. R., Pattison, A. J., Weaver, J. B., & Paulsen, K. D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/13/n02 · Cited by 161
Self-citationAlgebraic Helmholtz inversion in planar magnetic resonance elastography
Papazoglou, S., Hamhaber, U., Braun, J., & Sack, I. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/005 · Cited by 144
Johnson, C. L., McGarry, M., Houten, E. E. W. V., Weaver, J. B., Paulsen, K. D., Sutton, B. P., & Georgiadis, J. G. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24473 · Cited by 135
Self-citationMagnetic resonance elastography using 3D gradient echo measurements of steady‐state motion
Weaver, J. B., Van Houten, E. E. W., Miga, M. I., Kennedy, F. E., & Paulsen, K. D. (2001) · Medical Physics · doi:10.1118/1.1386776 · Cited by 111
Self-citationSiegmann, K., Xydeas, T., Sinkus, R., Kraemer, B., Vogel, U. H., & Claussen, C. D. (2009) · European Radiology · doi:10.1007/s00330-009-1566-4 · Cited by 74
MR elastography of the lung with hyperpolarized 3He
McGee, K. P., Hubmayr, R. D., & Ehman, R. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21465 · Cited by 46
Subzone based magnetic resonance elastography using a Rayleigh damped material model
Houten, E. E. W. V., Viviers, D., McGarry, M., Perriñez, P. R., Perreard, I. M., Weaver, J. B., & Paulsen, K. D. (2011) · Medical Physics · doi:10.1118/1.3557469 · Cited by 43
Self-citationEhman, R. L. (2009) · Radiology · doi:10.1148/radiol.2531091040 · Cited by 27
A three-parameter mechanical property reconstruction method for MR-based elastic property imaging
Houten, E. E. W. V., Doyley, M. M., Kennedy, F. E., Paulsen, K. D., & Weaver, J. B. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.842451 · Cited by 27
Self-citationDoyley, M. M., Perreard, I. M., Patterson, A. J., Weaver, J. B., & Paulsen, K. M. (2010) · Medical Physics · doi:10.1118/1.3454738 · Cited by 23
Self-citation
Cited by
Magnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging
Sack, I. (2022) · Nature Reviews Physics · doi:10.1038/s42254-022-00543-2 · Cited by 162
Hiscox, L. V., Johnson, C. L., McGarry, M. D. J., Perrins, M., Littlejohn, A., van Beek, E. J. R., Roberts, N., & Starr, J. M. (2018) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2018.01.010 · Cited by 118
Self-citationMedial temporal lobe viscoelasticity and relational memory performance
Schwarb, H., Johnson, C. L., McGarry, M. D. J., & Cohen, N. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.059 · Cited by 100
“Nonlinear inversion (NLI) estimated tissue viscoelasticity from the MRE displacement data (McGarry et al., 2012).”
Self-citation
Metadata
- Authors
- McGarry, M. D. J., Van Houten, E. E. W., Johnson, C. L., Georgiadis, J. G., Sutton, B. P., Weaver, J. B., & Paulsen, K. D.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-10
- Volume
- 39
- Issue
- 10
- Pages
- 6388-6396
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1988914162
- Cited by
- 158
- References
- 26
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.