The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Noise correlation in CBCT projection data and its application for noise reduction in low‐dose CBCT
Abstract
Purpose: To study the noise correlation properties of cone‐beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics‐based projection restoration algorithm for noise reduction in low‐dose CBCT. Methods: In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least‐squares (PWLS) criterion for noise reduction of low‐dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first‐ and second‐order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS‐Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS‐Dia) at the matched resolution. At the 2.0 mm resolution level in the axial‐plane noise resolution tradeoff analysis, the noise level of the PWLS‐Cor reconstruction is 6.3% lower than that of the PWLS‐Dia reconstruction. Conclusions: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics‐based projection restoration algorithm for low‐dose CBCT.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electronic noise is signal independent and can be modeled as additive Gaussian noise with correlation along rows due to sequential readout [15].”
From DeepDRR – A Catalyst for Machine Learning in Fluoroscopy-Guided Procedures (2018) · cites this paper as [15]
In the citing paper
“Noise in X-ray images is a composite of uncorrelated quantum noise due to photon statistics that becomes correlated due to pixel crosstalk, and correlated readout noise [15].”
From DeepDRR – A Catalyst for Machine Learning in Fluoroscopy-Guided Procedures (2018) · cites this paper as [15]
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
LSQR: An Algorithm for Sparse Linear Equations and Sparse Least Squares
Paige, C. C., & Saunders, M. A. (1982) · ACM Transactions on Mathematical Software · doi:10.1145/355984.355989 · Cited by 4,387
Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
Golub, G. H., Heath, M., & Wahba, G. (1979) · Technometrics · doi:10.1080/00401706.1979.10489751 · Cited by 3,934
The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems
Hansen, P. C., & O’Leary, D. P. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914086 · Cited by 3,137
Iterative Methods for Total Variation Denoising
Vogel, C. R., & Oman, M. E. (1996) · SIAM Journal on Scientific Computing · doi:10.1137/0917016 · Cited by 1,076
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533
Self-citation
Research works printed but not linked: 1
- Hsieh J., 2003, Computer Tomography, Principles, Design, Artifacts, and Recent Advances
Cited by
DeepDRR – A Catalyst for Machine Learning in Fluoroscopy-Guided Procedures
Unberath, M., Zaech, J.-N., Lee, S. C., Bier, B., Fotouhi, J., Armand, M., & Navab, N. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00937-3_12 · Cited by 145
“Since real flat panel detectors suffer from pixel crosstalk, we correlate the quantum noise of neighboring pixels by convolving the noise signal with a blurring kernel [15].”
BackgroundMethodInfluentialIterative CT Reconstruction Using Shearlet-Based Regularization
Vandeghinste, B., Goossens, B., Holen, R. V., Vanhove, C., Pižurica, A., Vandenberghe, S., & Staelens, S. G. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2275994 · Cited by 67
Enabling machine learning in X-ray-based procedures via realistic simulation of image formation
Unberath, M., Zaech, J.-N., Gao, C., Bier, B., Goldmann, F., Lee, S. C., Fotouhi, J., Taylor, R., Armand, M., & Navab, N. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02011-2 · Cited by 63
Tilley, S., Siewerdsen, J. H., & Stayman, J. W. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/296 · Cited by 60
Lanis, A., & del Canto, O. A. (2015) · The International Journal of Prosthodontics · doi:10.11607/ijp.4148 · Cited by 50
Big Data Analytics on Lung Cancer Diagnosis Framework With Deep Learning
Guan, P., Yu, K., Wei, W., Tan, Y., & Wu, J. (2023) · IEEE Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2023.3281638 · Cited by 44
Tilley, S., Jacobson, M. W., Cao, Q., Brehler, M., Sisniega, A., Zbijewski, W. B., & Stayman, J. W. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2779406 · Cited by 41
A unified material decomposition framework for quantitative dual‐ and triple‐energy CT imaging
Zhao, W., Vernekohl, D., Han, F., Han, B., Peng, H., Yang, Y., Xing, L., & Min, J. K. (2018) · Medical Physics · doi:10.1002/mp.12933 · Cited by 28
A general framework of noise suppression in material decomposition for dual‐energy CT
Petrongolo, M., Dong, X., & Zhu, L. (2015) · Medical Physics · doi:10.1118/1.4926780 · Cited by 28
3D Auto-Segmentation of Mandibular Condyles
Brosset, S., Dumont, M., Bianchi, J., Ruellas, A. C. D. O., Cevidanes, L., Yatabe, M., Gonçalves, J. R., Benavides, E., Soki, F. N., Paniagua, B., et al. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175692 · Cited by 21
Weighted adaptive non-local dictionary for low-dose CT reconstruction
Yu, H., Wang, S., Wu, W., Gong, C., Wang, L., Pi, Z., & Liu, F. (2020) · Signal Processing · doi:10.1016/j.sigpro.2020.107871 · Cited by 21
Limited-View Cone-Beam CT Reconstruction Based on an Adversarial Autoencoder Network With Joint Loss
Dai, X., Bai, J., Liu, T., & Xie, L. (2018) · IEEE Access · doi:10.1109/access.2018.2890135 · Cited by 20
Total image constrained diffusion tensor for spectral computed tomography reconstruction
Niu, S., Bian, Z., Zeng, D., Yu, G., Ma, J., & Wang, J. (2018) · Applied Mathematical Modelling · doi:10.1016/j.apm.2018.11.020 · Cited by 18
Self-citationSelf‐supervised denoising of projection data for low‐dose cone‐beam CT
Choi, K., Kim, S. H., & Kim, S. (2023) · Medical Physics · doi:10.1002/mp.16421 · Cited by 17
Li, D., Wang, H., Yin, Y., & Wang, X. (2011) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v12i4.3527 · Cited by 17
Dietze, M. M. A., Bastiaannet, R., Kunnen, B., van der Velden, S., Lam, M. G. E. H., Viergever, M. A., & de Jong, H. W. A. M. (2019) · Medical Physics · doi:10.1002/mp.13653 · Cited by 16
Mahmoudi, G., Fouladi, M. R., Ay, M. R., Rahmim, A., & Ghadiri, H. (2019) · Journal of Instrumentation · doi:10.1088/1748-0221/14/08/p08023 · Cited by 15
Wang, Y., & Qi, Z. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-180412 · Cited by 14
Improving the accuracy of CT dimensional metrology by a novel beam hardening correction method
Zhang, X., Li, L., Zhang, F., Xi, X., Deng, L., & Yan, B. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/26/1/015007 · Cited by 14
Hehn, L., Tilley, S., Pfeiffer, F., & Stayman, J. W. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab489e · Cited by 13
Song, Y., Zhang, W., Zhang, H., Wang, Q., Xiao, Q., Li, Z., Wei, X., Lai, J., Wang, X., Li, W., et al. (2020) · Radiation Oncology · doi:10.1186/s13014-020-01630-3 · Cited by 13
Self-citationReconstruction of sparse-view X-ray computed tomography using adaptive iterative algorithms
Liu, L., Lin, W., & Jin, M. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.11.001 · Cited by 11
Liang, Z., Wei, H., Liu, G., Cheng, M., Gao, J., Li, S., & Tian, X. (2024) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2023.100809 · Cited by 10
Sathish, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-83974-4 · Cited by 9
Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties
Shi, Q., Sun, N., Sun, T., Wang, J., & Tan, S. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003299 · Cited by 9
Self-citationTian, X., Zeng, D., Zhang, S., Huang, J., Zhang, H., He, J., Lu, L., Xi, W.-W., Ma, J., & Bian, Z. (2016) · Journal of X-Ray Science and Technology · doi:10.3233/xst-160593 · Cited by 9
Self-citationShangguan, H., Zhang, X., Cui, X., Liu, Y., Zhang, Q., & Gui, Z. (2019) · Signal Image and Video Processing · doi:10.1007/s11760-019-01496-3 · Cited by 7
An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction
Li, J., Niu, S., Huang, J., Bian, Z., Feng, Q., Yu, G., Liang, Z., Chen, W., & Ma, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140579 · Cited by 6
Self-citationLin, J., Zhang, H., Huang, J., Bian, Z., Zhang, S., Wang, Y., Liao, Y., Li, S., Zhang, H., Zeng, D., et al. (2018) · Journal of X-Ray Science and Technology · doi:10.3233/xst-17272 · Cited by 6
Self-citationYang, F., Zhao, F., Liu, Y., Liu, M., & Liu, M. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01314-4 · Cited by 5
Estimation of bias and variance of measurements made from tomography scans
Bradley, R. S. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/9/095402 · Cited by 5
Kim, H. J., Choi, J., & Lee, Y. (2024) · Applied Sciences · doi:10.3390/app14167058 · Cited by 5
Data correlation based noise level estimation for cone beam projection data
Bai, T., Yan, H., Ouyang, L., Staub, D., Wang, J., Jia, X., Jiang, S. B., & Mou, X. (2017) · Journal of X-Ray Science and Technology · doi:10.3233/xst-17266 · Cited by 4
Self-citationZhang, S., Lv, B., Zheng, X., Li, Y., Ge, W., Zhang, L., Mo, F., & Qiu, J. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.860135 · Cited by 4
Tilley, S., Siewerdsen, J. H., Zbijewski, W. B., & Stayman, J. W. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216126 · Cited by 3
Jia, X., Liao, Y., Zeng, D., Zhang, H., Zhang, Y., He, J., Bian, Z., Wang, Y., Tao, X., Liang, Z., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaebc9 · Cited by 3
Self-citationRazi, T., Manaf, N. V., Yadekar, M., Razi, S., & Gheibi, S. (2019) · Journal of Advanced Oral Research · doi:10.1177/2320206819870898 · Cited by 3
Amasya, H., Günay, O., Kesmezacar, F. F., Tunçman, D., Yeyin, N., Kekeç, E., Zengin, T., Orhan, K., Karaçam, S. Ç., & Demır, M. (2025) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/0115734056316438241203095215 · Cited by 2
Validation of a Monte Carlo model of a large‐format kV flat‐panel system
Lowther, N., Myronakis, M. E., Harris, T. C., Berbeco, R. I., Jacobson, M., Etemadpour, R., Ferguson, D., Fueglistaller, R., Arroyo, P. C., Birrer, V., et al. (2025) · Medical Physics · doi:10.1002/mp.18093 · Cited by 2
Direct Reconstruction of CT-Based Attenuation Correction Images for PET With Cluster-Based Penalties
Kim, S. M., Alessio, A. M., Man, B. D., & Kinahan, P. E. (2017) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2017.2654680 · Cited by 2
Kim, S. M., Lee, T.-C., & Kinahan, P. E. (2020) · Journal of the Korean Physical Society · doi:10.3938/jkps.77.177 · Cited by 1
Cone-Beam Computed Tomography in Dental Diagnostics
Sathish, S. (2026) · Springer eBooks · doi:10.1007/978-981-92-0489-2_6 · Cited by 1
Chen, M., Tao, X., Li, H., Chen, W., & Zhang, H. (2018) · Europe PMC (PubMed Central) · doi:10.3969/j.issn.1673-4254.2018.01.08 · Cited by 1
Self-citationLow-dose CT image reconstruction based on a deep neural network
Li, J., & Huang, X. (2022) · IEEE Joint International Information Technology and Artificial Intelligence Conference (ITAIC) · doi:10.1109/itaic54216.2022.9836873 · Cited by 1
Low-Dose CT Image Reconstruction Based on a Residual Network
Li, J., & Huang, X. (2024) · IEEE Information Technology, Networking, Electronic and Automation Control Conference (ITNEC) · doi:10.1109/itnec60942.2024.10733047 · Cited by 1
Compound Poisson noise verification for X-ray flat panel imager
Hsieh, H.-H., Ni, Y.-C., Tseng, S.-P., Tseng, F.-P., & Chen, L. (2015) · IEEE International Conference on Imaging Systems and Techniques (IST) · doi:10.1109/ist.2015.7294576
Using Photoshop Program in Reducing Motion and Noise Artifacts On Cone Beam Ct
Geduk, G., İçen, M., & Geduk, Ş. E. (2021) · Selcuk Dental Journal · doi:10.15311/selcukdentj.649079
Cone Beam Computed Tomography in Implant Dentistry- An update
Bollen, C. M. L. (2023) · doi:10.37191/mapsci-jdr-4(1)-029
Metadata
- Authors
- Zhang, H., Ouyang, L., Ma, J., Huang, J., Chen, W., & Wang, J.
- Affiliations
- Southern Medical University (CN)
- The University of Texas Southwestern Medical Center (US)
- Corresponding author
- Ma, Jianhua
- Wang, Jing
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2014-02-19
- Volume
- 41
- Issue
- 3
- Pages
- 031906-031906
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2014598003
- Cited by
- 47
- References
- 32
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 4 · 2019: 6 · 2018: 8 · 2017: 3 · 2016: 4 · 2015: 5 · 2014: 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 559 d)
- Locations
- Medical Physics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- NNSFC (81371544, 81000613, 81101046)
- National Natural Science Foundation of China (81371544, 81000613, 81101046)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Keywords
- cone-beam computed tomography, noise correlation, low-dose CT, noise reduction, penalized weighted least squares, covariance matrix, noise models, pelvis phantom
- MeSH terms
- Algorithms, Anthropometry, Humans, Image Processing, Computer-Assisted, Male, Radiation Dosage, Radiographic Image Enhancement, Radiographic Image Interpretation, Computer-Assisted, Reproducibility of Results, Models, Statistical, Poisson Distribution, Least-Squares Analysis, Phantoms, Imaging, Cone-Beam Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.