The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
ibex: An open infrastructure software platform to facilitate collaborative work in radiomics
Open accessAbstract
Purpose: Radiomics, which is the high‐throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (ibex), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The ibex software package was developed using the matlab and c/c++ programming languages. The software architecture deploys the modern model‐view‐controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, ibex is self‐contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, ibex provides an integrated development environment on top of matlab and c/c++, so users are not limited to its built‐in functions. In the ibex developer studio, users can plug in, debug, and test new algorithms, extending ibex’s functionality. ibex also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm‐related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the ibex workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the ibex software to be intuitive, powerful, and easy to use. ibex can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand‐alone ibex and ibex’s source code can be downloaded. Conclusions: The authors successfully implemented ibex, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
A cookbook for using the model-view controller user interface paradigm in Smalltalk-80
Krasner, G., & Pope, S. (1988) · Journal of Object-oriented Programming · doi:10.5555/50757.50759 · Cited by 1,629
Textural features corresponding to textural properties
Amadasun, M., & King, R. (1989) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.44046 · Cited by 1,148
A Five-Gene Signature and Clinical Outcome in Non–Small-Cell Lung Cancer
Chen, H.-Y., Yu, S.-L., Chen, C.-H., Chang, G.-C., Chen, C.-Y., Yuan, A., Cheng, C.-L., Wang, C.-H., Terng, H.-J., Kao, S.-F., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa060096 · Cited by 935
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
MaZda—A software package for image texture analysis
Szczypiński, P. M., Strzelecki, M., Materka, A., & Klepaczko, A. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.08.005 · Cited by 712
Texture information in run-length matrices
Tang, X. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.725367 · Cited by 654
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629
Ganeshan, B., Panayiotou, E., Burnand, K., Dizdarevic, S., & Miles, K. (2012) · European Radiology · doi:10.1007/s00330-011-2319-8 · Cited by 505
Introduction to the DICOM standard
Mildenberger, P., Eichelberg, M., & Martin, E. (2002) · European Radiology · doi:10.1007/s003300101100 · Cited by 471
Non–Small Cell Lung Cancer: Histopathologic Correlates for Texture Parameters at CT
Ganeshan, B., Goh, V., Mandeville, H. C., Ng, Q. S., Hoskin, P. J., & Miles, K. A. (2013) · Radiology · doi:10.1148/radiol.12112428 · Cited by 447
Ganeshan, B., Abaleke, S., Young, R. C. D., Chatwin, C. R., & Miles, K. A. (2010) · Cancer Imaging · doi:10.1102/1470-7330.2010.0021 · Cited by 324
Jackson, A., O'Connor, J. P. B., Parker, G. J. M., & Jayson, G. C. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0238 · Cited by 299
Textural analysis of contrast‐enhanced MR images of the breast
Gibbs, P., & Turnbull, L. W. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10496 · Cited by 287
Texture Analysis of Aggressive and Nonaggressive Lung Tumor CE CT Images
Al-Kadi, O. S., & Watson, D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919735 · Cited by 268
Fried, D. V., Tucker, S. L., Zhou, S., Liao, Z., Mawlawi, O., Ibbott, G., & Court, L. E. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.07.020 · Cited by 213
Self-citationWin, T., Miles, K. A., Janes, S. M., Ganeshan, B., Shastry, M., Endozo, R., Meagher, M., Shortman, R. I., Wan, S., Kayani, I., et al. (2013) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-1307 · Cited by 203
Machtay, M., Duan, F., Siegel, B. A., Snyder, B. S., Gorelick, J. J., Reddin, J. S., Munden, R., Johnson, D. W., Wilf, L. H., DeNittis, A., et al. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.47.5947 · Cited by 175
Fang, Y.-H. D., Lin, C., Shih, M.-J., Wang, H., Ho, T., Liao, C.-T., & Yen, T. (2014) · BioMed Research International · doi:10.1155/2014/248505 · Cited by 133
Hunter, L. A., Krafft, S. P., Stingo, F. C., Choi, H., Martel, M. K., Kry, S. F., & Court, L. E. (2013) · Medical Physics · doi:10.1118/1.4829514 · Cited by 130
Self-citationRavanelli, M., Farina, D., Morassi, M., Roca, E., Cavalleri, G., Tassi, G., & Maroldi, R. (2013) · European Radiology · doi:10.1007/s00330-013-2965-0 · Cited by 122
Tan, H., Liu, T., Wu, Y. G., Thacker, J., Shenkar, R., Mikati, A. G., Shi, C., Dykstra, C., Wang, Y., Prasad, P. V., et al. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000043 · Cited by 96
A Multigene Assay Is Prognostic of Survival in Patients with Early-Stage Lung Adenocarcinoma
Raz, D. J., Ray, M., Kim, J. Y., He, B., Tarón, M., Skrzypski, M. T., Segal, M. R., Gandara, D. R., Rosell, R., & Jablons, D. M. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0544 · Cited by 85
Towards a Framework for Differential Unit Testing of Object-Oriented Programs
Xie, T., Taneja, K., Kale, S., & Marinov, D. (2007) · International Workshop on Automation of Software Test (AST) · doi:10.1109/ast.2007.15 · Cited by 33
Lung texture in serial thoracic CT scans: Assessment of change introduced by image registrationa)
Cunliffe, A. R., Al‐Hallaq, H., Labby, Z. E., Pelizzari, C. A., Straus, C. M., Sensakovic, W. F., Ludwig, M. S., & Armato, S. G. (2012) · Medical Physics · doi:10.1118/1.4730505 · Cited by 29
Canuto, H. C., McLachlan, C., Kettunen, M. I., Velić, M., Krishnan, A. S., Neves, A., de Backer, M., Hu, D., Hobson, M., & Brindle, K. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21946 · Cited by 21
Cunliffe, A. R., Armato, S. G., Fei, X. M., et al. (2013) · Medical Physics · doi:10.1118/1.4805110 · Cited by 20
Quantifying Heterogeneity in Dynamic Contrast-Enhanced MRI Parameter Maps
Rose, C. J., Mills, S. J., O’Connor, J. P. B., Buonaccorsi, G. A., Roberts, C., Watson, Y., Whitcher, B. J., Jayson, G. C., Jackson, A., & Parker, G. J. M. (2007) · Springer eBooks · doi:10.1007/978-3-540-75759-7_46 · Cited by 17
Developing Predictive Models for Lung Tumor Analysis
Basu, S. (2012) · Digital Commons - University of South Florida (University of South Florida) · Cited by 8
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Measuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Self-citationBerenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Metadata
- Authors
- Zhang, L., Fried, D. V., Fave, X. J., Hunter, L. A., Yang, J., & Court, L. E.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2015-02-25
- Volume
- 42
- Issue
- 3
- Pages
- 1341-1353
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2077763531
- Cited by
- 316
- References
- 35
- FWCI
- 17.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.