The DOI matches its Crossref record.
NMR blood flow imaging using multiecho, phase contrast sequences
Abstract
Moving nuclei, in contrast to stationary nuclei, experience a phase shift in the presence of a balanced gradient. Monitoring of this phase shift can be used to measure the flow velocity of moving nuclei. A specific scan sequence for blood flow imaging is presented. This sequence uses multiple echoes as well as a phase contrast approach to generate both conventional anatomical images and blood flow images from the same data. Images of a phantom and a human volunteer demonstrating the accuracy of the method are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
A new look at cerebrospinal fluid circulation
Brinker, T., Stopa, E., Morrison, J., & Klinge, P. (2014) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-11-10 · Cited by 819
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Lotz, J., Meier, C., Leppert, A., & Galanski, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.3.g02ma11651 · Cited by 673
Concomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Encoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
NMR microscopy of dynamic displacements: k-space and q-space imaging
Callaghan, P. T., Eccles, C. D., & Xia, Y. (1988) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/21/8/017 · Cited by 298
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Metadata
- Authors
- O'Donnell, M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 12
- Issue
- 1
- Pages
- 59-64
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2104702473
- Cited by
- 158
- References
- 0
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.