The DOI matches its Crossref record.
Computer‐aided detection of mammographic microcalcifications: Pattern recognition with an artificial neural network
Abstract
We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty‐two mammograms with clustered microcalcifications were selected from patient files. The clusters on the mammograms were ranked by experienced mammographers and divided into an obvious group, an average group, and a subtle group. The average and subtle groups were combined and randomly divided into two sets, each of which was used as training or test set alternately. The obvious group served as an additional independent test set. Regions of interest (ROIs) containing potential individual microcalcifications were first located on each mammogram by the automated detection program. The ROIs from one set of the mammograms were used to train CNNs of different configurations with a back‐propagation method. The generalization capability of the trained CNNs was then examined by their accuracy of classifying the ROIs from the other set and from the obvious group. The classification accuracy of the CNNs for the ROIs was evaluated by receiver operating characteristic (ROC) analysis. It was found that CNNs of many different configurations can reach approximately the same performance level, with the area under the ROC curve (Az) of 0.9. We incorporated a trained CNN into the detection program and evaluated the improvement of the detection accuracy by the CNN using free response ROC analysis. Our results indicated that, over a wide range of true‐positive (TP) cluster detection rate, the CNN classifier could reduce the number of false‐positive (FP) clusters per image by more than 70%. For the obvious cases, at a TP rate of 100%, the FP rate reduced from 0.35 cluster per image to 0.1 cluster per image. For the average and subtle cases, the detection accuracy improved from a TP rate of 87% at an FP rate of four clusters per image to a TP rate of 90% at an FP rate of 1.5 clusters per image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
Greenspan, H., van Ginneken, B., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553401 · Cited by 1,700
Machine learning for medical imaging
Erickson, B. J., Korfiatis, P., Akkus, Z., & Kline, T. L. (2017) · RadioGraphics · doi:10.1148/rg.2017160130 · Cited by 1,672
Image processing with neural networks—a review
Egmont-Petersen, M., de Ridder, D., & Handels, H. (2002) · Pattern Recognition · doi:10.1016/s0031-3203(01)00178-9 · Cited by 1,186
Deep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Self-citationDeep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Self-citationMachine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Birdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Sahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538937 · Cited by 420
Self-citationComputer‐aided diagnosis in the era of deep learning
Chan, H., Hadjiiski, L. M., & Samala, R. K. (2020) · Medical Physics · doi:10.1002/mp.13764 · Cited by 358
Self-citationArtificial convolution neural network techniques and applications for lung nodule detection
Lo, S.-C. B., Lou, S.-L. A., Lin, J.-S., Freedman, M. T., Chien, M. V., & Mun, S. K. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.476112 · Cited by 348
Self-citationArtificial convolution neural network for medical image pattern recognition
Lo, S.-C. B., Chan, H.-P., Lin, J.-S., Li, H., Freedman, M. T., & Mun, S. K. (1995) · Neural Networks · doi:10.1016/0893-6080(95)00061-5 · Cited by 321
Self-citationGiger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationComputer-Aided Detection and Diagnosis in Mammography
Sampat, M. P., Markey, M. K., & Bovik, A. C. (2005) · Handbook of Image and Video Processing · doi:10.1016/b978-012119792-6/50130-3 · Cited by 302
Samala, R. K., Chan, H., Hadjiiski, L., Helvie, M. A., Wei, J., & Cha, K. (2016) · Medical Physics · doi:10.1118/1.4967345 · Cited by 289
Self-citationGoing Deep in Medical Image Analysis: Concepts, Methods, Challenges, and Future Directions
Altaf, F., Islam, S. M. S., Akhtar, N., & Janjua, N. K. (2019) · IEEE Access · doi:10.1109/access.2019.2929365 · Cited by 286
Deep convolutional neural networks for mammography: advances, challenges and applications
Abdelhafiz, D., Yang, C., Ammar, R., & Nabavi, S. (2019) · BMC Bioinformatics · doi:10.1186/s12859-019-2823-4 · Cited by 274
Deep learning in mammography and breast histology, an overview and future trends
Hamidinekoo, A., Denton, E., Rampun, A., Honnor, K., & Zwiggelaar, R. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.006 · Cited by 273
Metadata
- Authors
- Chan, H., Lo, S. B., Sahiner, B., Lam, K. L., & Helvie, M. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 22
- Issue
- 10
- Pages
- 1555-1567
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2112525988
- Cited by
- 208
- References
- 0
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.