The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Automated three‐dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
Abstract
Approaches using measures of voxel intensity similarity are showing promise in fully automating magnetic resonance (MR) and positron emission tomography (PET) image registration in the head, without requiring extraction and identification of corresponding structures. In this paper a method of multiresolution optimization of these measures is described and five alternative measures are compared: cross correlation, minimization of corresponding PET intensity variation, moments of the distribution of values in the intensity feature space, entropy of the intensity feature space and mutual information. Their ability to recover registration is examined for ten clinically acquired image pairs with respect to the size of initial misregistration, the precision of the final result, and the accuracy assessed by visual inspection. The mutual information measure proved the most robust to initial starting estimate, successfully registering 98.8% of 900 trial misregistrations. Success is defined as providing a visually acceptable solution to a trained observer. A high resolution search ( mm step size) of 30 trial misregistrations showed that optimization using the mutual information measure provided solutions with 0.13 mm, 0.11 mm and 0.17 mm standard deviations in the three Cartesian axes of the translation vector and 0.2°, 0.3° and 0.2° standard deviations for rotations about the three axes. The algorithm takes between 4 and 8 minutes to run on a typical workstation, including visual inspection of the result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationAn Introduction to Information Theory.
Mallows, C. L., & Reza, F. M. (1964) · The American Mathematical Monthly · doi:10.2307/2311344 · Cited by 771
MRI-PET Correlation in Three Dimensions Using a Volume-of-Interest (VOI) Atlas
Evans, A. C., Marrett, S., Torrescorzo, J., Ku, S., & Collins, L. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.40 · Cited by 264
Registration of MR and CT images for skull base surgery using point-like anatomical features
Hill, D. L. G., Hawkes, D. J., Crossman, J. E., Gleeson, M. J., Cox, T. C. S., Bracey, E. E. C. M. L., Strong, A. J., & Graves, P. (1991) · The British Journal of Radiology · doi:10.1259/0007-1285-64-767-1030 · Cited by 198
Self-citationAutomated multimodality image registration using information theory
Collignon, A. M. F. (1995) · Information Processing in Medical Imaging · Cited by 190
New approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Three-dimensional alignment of functional and morphological tomograms.
Pietrzyk, U., Herholz, K., & Wd, H. (1990) · PubMed · Cited by 153
Voxel similarity measures for automated image registration
Hill, D., Studholme, C., & Hawkes, D. J. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.185180 · Cited by 149
Self-citation3D Multi-Modality Medical Image Registration Using Feature Space Clustering
Collignon, A. M. F., Vandermeulen, D., Suetens, P., & Marchal, G. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2_22 · Cited by 113
Accuracy of registration of PET, SPECT and MR images of a brain phantom.
Turkington, T. G., Jaszczak, R. J., Pelizzari, C. A., Harris, C. C., MacFall, J. R., Hoffman, J. M., & Coleman, R. E. (1993) · PubMed · Cited by 92
Incorporating connected region labelling into automated image registration using mutual information
Studholme, C., Hill, D., & Hawkes, D. J. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534054 · Cited by 84
Self-citationAlignment by maximisation of mutual information
Viola, P. A. (1993) · Cited by 81
Neelin, P., Crossman, J. E., Hawkes, D. J., Ma, Y., & Evans, A. C. (1993) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(93)90028-l · Cited by 51
Self-citationWong, J., Studholme, C., Hawkes, D. J., & Maisey, M. N. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00841402 · Cited by 48
Self-citationAutomated 3D Registration of Truncated MR and CT Images of the Head.
Studholme, C., Hill, D., & Hawkes, D. J. (1995) · British Machine Vision Conference (BMVC) · doi:10.5244/c.9.3 · Cited by 45
Self-citation
Cited by
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationA reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationHill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citation
Metadata
- Authors
- Studholme, C., Hill, D. L. G., & Hawkes, D. J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 24
- Issue
- 1
- Pages
- 25-35
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1991622227
- Cited by
- 675
- References
- 18
- FWCI
- 35.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.