The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Automated three‐dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
Abstract
Approaches using measures of voxel intensity similarity are showing promise in fully automating magnetic resonance (MR) and positron emission tomography (PET) image registration in the head, without requiring extraction and identification of corresponding structures. In this paper a method of multiresolution optimization of these measures is described and five alternative measures are compared: cross correlation, minimization of corresponding PET intensity variation, moments of the distribution of values in the intensity feature space, entropy of the intensity feature space and mutual information. Their ability to recover registration is examined for ten clinically acquired image pairs with respect to the size of initial misregistration, the precision of the final result, and the accuracy assessed by visual inspection. The mutual information measure proved the most robust to initial starting estimate, successfully registering 98.8% of 900 trial misregistrations. Success is defined as providing a visually acceptable solution to a trained observer. A high resolution search ( mm step size) of 30 trial misregistrations showed that optimization using the mutual information measure provided solutions with 0.13 mm, 0.11 mm and 0.17 mm standard deviations in the three Cartesian axes of the translation vector and 0.2°, 0.3° and 0.2° standard deviations for rotations about the three axes. The algorithm takes between 4 and 8 minutes to run on a typical workstation, including visual inspection of the result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationAn Introduction to Information Theory.
Mallows, C. L., & Reza, F. M. (1964) · The American Mathematical Monthly · doi:10.2307/2311344 · Cited by 771
MRI-PET Correlation in Three Dimensions Using a Volume-of-Interest (VOI) Atlas
Evans, A. C., Marrett, S., Torrescorzo, J., Ku, S., & Collins, L. (1991) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1991.40 · Cited by 264
Registration of MR and CT images for skull base surgery using point-like anatomical features
Hill, D. L. G., Hawkes, D. J., Crossman, J. E., Gleeson, M. J., Cox, T. C. S., Bracey, E. E. C. M. L., Strong, A. J., & Graves, P. (1991) · The British Journal of Radiology · doi:10.1259/0007-1285-64-767-1030 · Cited by 198
Self-citationAutomated multimodality image registration using information theory
Collignon, A. M. F. (1995) · Information Processing in Medical Imaging · Cited by 190
New approach to 3-D registration of multimodality medical images by surface matching:
Jiang, H., Robb, R. A., & Holton Tainter, K. S. (1992) · SPIE Proceedings · doi:10.1117/12.131078 · Cited by 162
Three-dimensional alignment of functional and morphological tomograms.
Pietrzyk, U., Herholz, K., & Wd, H. (1990) · PubMed · Cited by 153
Cited by
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationA reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationHill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citationVirtual in vivo interactive dissection of white matter fasciculi in the human brain
Catani, M., Howard, R. J., Pajevic, S., & Jones, D. K. (2002) · NeuroImage · doi:10.1006/nimg.2002.1136 · Cited by 1,637
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Hammers, A., Allom, R., Koepp, M. J., Free, S. L., Myers, R., Lemieux, L., Mitchell, T. N., Brooks, D. J., & Duncan, J. S. (2003) · Human Brain Mapping · doi:10.1002/hbm.10123 · Cited by 1,286
In vivo imaging of microglial activation with [11C](R)-PK11195 PET in idiopathic Parkinson's disease
Gerhard, A., Pavese, N., Hotton, G., Turkheimer, F., Es, M., Hammers, A., Eggert, K., Oertel, W., Banati, R. B., & Brooks, D. J. (2006) · Neurobiology of Disease · doi:10.1016/j.nbd.2005.08.002 · Cited by 1,200
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Self-citationMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Dopamine release from nigral transplants visualized in vivo in a Parkinson's patient
Piccini, P., Brooks, D. J., Björklund, A., Gunn, R. N., Grasby, P. M., Rimoldi, O., Brundin, P., Hagell, P., Rehncrona, S., Widner, H., et al. (1999) · Nature Neuroscience · doi:10.1038/16060 · Cited by 700
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Image registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
The peripheral benzodiazepine binding site in the brain in multiple sclerosis
Banati, R. B., Newcombe, J., Gunn, R. N., Cagnin, A., Turkheimer, F., Heppner, F., Price, G., Wegner, F., Giovannoni, G., Miller, D. H., et al. (2000) · Brain · doi:10.1093/brain/123.11.2321 · Cited by 661
Rohlfing, T., Brandt, R., Menzel, R., & Maurer, C. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.010 · Cited by 573
Bozzali, M. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.6.742 · Cited by 568
Diffusion tensor magnetic resonance imaging in multiple sclerosis
Filippi, M., Cercignani, M., Inglese, M., Horsfield, M. A., & Comi, G. (2001) · Neurology · doi:10.1212/wnl.56.3.304 · Cited by 546
Connectivity-Based Parcellation of Broca's Area
Anwander, A., Tittgemeyer, M., von Cramon, D., Friederici, A., & Knosche, T. (2006) · Cerebral Cortex · doi:10.1093/cercor/bhk034 · Cited by 531
Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533
Amyloid, hypometabolism, and cognition in Alzheimer disease: An [11C]PIB and [18F]FDG PET study
Edison, P., Archer, H. A., Hinz, R., Hammers, A., Pavese, N., Tai, Y. F., Hotton, G., Cutler, D., Fox, N., Kennedy, A., et al. (2007) · Neurology · doi:10.1212/01.wnl.0000244749.20056.d4 · Cited by 518
Compulsive drug use linked to sensitized ventral striatal dopamine transmission.
Evans, A. H., Pavese, N., Lawrence, A. D., Tai, Y. F., Appel, S., Doder, M., Brooks, D. J., Lees, A. J., & Piccini, P. (2006) · Annals of Neurology · doi:10.1002/ana.20822 · Cited by 473
Rohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00066 · Cited by 404
Self-citationFast and robust multi-atlas segmentation of brain magnetic resonance images
Lötjönen, J. M., Wolz, R., Koikkalainen, J. R., Thurfjell, L., Waldemar, G., Soininen, H., & Rueckert, D. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.026 · Cited by 391
Frangi, A. F., Rueckert, D., Schnabel, J. A., & Niessen, W. J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804426 · Cited by 380
Rohlfing, T., & Maurer, C. R. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.808506 · Cited by 373
Automatic segmentation of brain MRIs of 2-year-olds into 83 regions of interest
Gousias, I. S., Rueckert, D., Heckemann, R. A., Dyet, L. E., Boardman, J. P., Edwards, A. D., & Hammers, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.034 · Cited by 355
What is the best similarity measure for motion correction in fMRI time series?
Freire, L., Roche, A., & Mangin, J.-F. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009383 · Cited by 353
Diffusion limited oxygen delivery following head injury*
Menon, D. K., Coles, J. P., Gupta, A. K., Fryer, T. D., Smielewski, P., Chatfield, D. A., Aigbirhio, F., Skepper, J. N., Minhas, P. S., Hutchinson, P. J., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000127777.16609.08 · Cited by 340
Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308
Tremor in Parkinson’s disease and serotonergic dysfunction: An 11 C-WAY 100635 PET study
Doder, M., Rabiner, E. A., Turjanski, N., Lees, A. J., & Brooks, D. J. (2003) · Neurology · doi:10.1212/01.wnl.0000031424.51127.2b · Cited by 302
BioImage Suite: An integrated medical image analysis suite: An update
Papademetris, X., Jackowski, M., Rajeevan, N., DiStasio, M., Okuda, H., Constable, R. T., & Staib, L. (2006) · The Insight Journal · doi:10.54294/2g80r4 · Cited by 298
Coles, J. P., Minhas, P. S., Fryer, T. D., Smielewski, P., Aigbirihio, F., Donovan, T., Downey, S. P. M. J., Williams, G., Chatfield, D., Matthews, J. C., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00002 · Cited by 296
The Role of Insulin in Human Brain Glucose Metabolism
Bingham, E. M., Hopkins, D., Smith, D., Pernet, A., Hallett, W., Reed, L., Marsden, P. K., & Amiel, S. A. (2002) · Diabetes · doi:10.2337/diabetes.51.12.3384 · Cited by 293
Cercignani, M. (2001) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.70.3.311 · Cited by 291
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Evolution of microglial activation in patients after ischemic stroke: a [11C](R)-PK11195 PET study
Gerhard, A., Schwarz, J., Myers, R., Wise, R., & Banati, R. B. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.034 · Cited by 284
Mapping of brain metabolite distributions by volumetric proton MR spectroscopic imaging (MRSI)
Maudsley, A. A., Domenig, C., Govind, V., Darkazanli, A., Studholme, C., Arheart, K., & Bloomer, C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21875 · Cited by 283
Self-citationLactate: A Preferred Fuel for Human Brain Metabolism in Vivo
Smith, D., Pernet, A., Hallett, W. A., Bingham, E., Marsden, P. K., & Amiel, S. A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000063991.19746.11 · Cited by 282
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Self-citationHyperventilation following head injury: Effect on ischemic burden and cerebral oxidative metabolism*
Coles, J. P., Fryer, T. D., Coleman, M. R., Smielewski, P., Gupta, A. K., Minhas, P. S., Aigbirhio, F., Chatfield, D. A., Williams, G. B., Boniface, S., et al. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000254066.37187.88 · Cited by 276
Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm
LORENZOVALDES, M. (2004) · Medical Image Analysis · doi:10.1016/j.media.2004.06.005 · Cited by 273
Incidence and Mechanisms of Cerebral Ischemia in Early Clinical Head Injury
Coles, J. P., Fryer, T. D., Smielewski, P., Chatfield, D. A., Steiner, L. A., Johnston, A. J., Downey, S. P. M. J., Williams, G. B., Aigbirhio, F., Hutchinson, P. J., et al. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000103022.98348.24 · Cited by 270
Cognitive deficits and striato-frontal dopamine release in Parkinson's disease
Sawamoto, N., Piccini, P., Hotton, G., Pavese, N., Thielemans, K., & Brooks, D. J. (2008) · Brain · doi:10.1093/brain/awn054 · Cited by 263
Rohlfing, T., Maurer, C. R., O'Dell, W. G., & Zhong, J. (2004) · Medical Physics · doi:10.1118/1.1644513 · Cited by 262
Medical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationInterpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Schnabel, J. A., Tanner, C., Castellano-Smith, A. D., Degenhard, A., Leach, M. O., Hose, D. R., Hill, D. L. G., & Hawkes, D. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808367 · Cited by 255
Self-citationThe Effect of Paroxetine on 5-HT2A Receptors in Depression: An [18F]Setoperone PET Imaging Study
Meyer, J. H., Kapur, S., Eisfeld, B., Brown, G. M., Houle, S., DaSilva, J., Wilson, A. A., Rafi-Tari, S., Mayberg, H. S., & Kennedy, S. H. (2001) · American Journal of Psychiatry · doi:10.1176/appi.ajp.158.1.78 · Cited by 231
Banati, R. B., Goerres, G. W., Myers, R., Gunn, R. N., Turkheimer, F. E., Kreutzberg, G. W., Brooks, D. J., Jones, T., & Duncan, J. S. (1999) · Neurology · doi:10.1212/wnl.53.9.2199 · Cited by 224
Ginovart, N., Wilson, A. A., Meyer, J. H., Hussey, D., & Houle, S. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200111000-00010 · Cited by 209
Elevated brain monoamine oxidase A binding in the early postpartum period
Sacher, J., Wilson, A. A., Houle, S., Rusjan, P., Hassan, S., Bloomfield, P. M., Stewart, D. E., & Meyer, J. H. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2010.32 · Cited by 202
In vivo imaging of microglial activation with [11C](R)‐PK11195 PET in progressive supranuclear palsy
Gerhard, A., Trender‐Gerhard, I., Turkheimer, F., Quinn, N. P., Bhatia, K. P., & Brooks, D. J. (2006) · Movement Disorders · doi:10.1002/mds.20668 · Cited by 171
Huntington's disease progression
Andrews, T. C., Weeks, R. A., Turjanski, N., Gunn, R. N., Watkins, L. H. A., Sahakian, B., Hodges, J. R., Rosser, A. E., Wood, N. W., & Brooks, D. J. (1999) · Brain · doi:10.1093/brain/122.12.2353 · Cited by 169
Tauscher, J., Hussain, T., Agid, O., Verhoeff, N. P. L. G., Wilson, A. A., Houle, S., Remington, G., Zipursky, R. B., & Kapur, S. (2004) · American Journal of Psychiatry · doi:10.1176/appi.ajp.161.9.1620 · Cited by 159
“5-T scanner, proton density maps) and was coregistered to the composite [11C]raclopride and [11C]SCH23390 PET scans by using RView8/mpr software (28).”
MethodRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
A diffusion tensor MRI study of patients with MCI and AD with a 2-year clinical follow-up
Scola, E., Bozzali, M., Agosta, F., Magnani, G., Franceschi, M., Sormani, M. P., Cercignani, M., Pagani, E., Falautano, M., Filippi, M., et al. (2010) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.189639 · Cited by 98
Montgomery, A. J., Asselin, M.-C., Farde, L., & Grasby, P. M. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600339 · Cited by 85
Otake, Y., Schafer, S., Stayman, J. W., Zbijewski, W., Kleinszig, G., Graumann, R., Khanna, A. J., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5485 · Cited by 79
(2003) · PubMed Central · Cited by 76
Suridjan, I., Rusjan, P. M., Voineskos, A. N., Selvanathan, T., Setiawan, E., Strafella, A. P., Wilson, A. A., Meyer, J. H., Houle, S., & Mizrahi, R. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.09.021 · Cited by 71
Uncovering Disease Mechanisms in a Novel Mouse Model Expressing Humanized APOEε4 and Trem2*R47H
Kotredes, K. P., Oblak, A., Pandey, R. S., Lin, P. B.-C., Garceau, D., Williams, H., Uyar, A., O’Rourke, R., O’Rourke, S., Ingraham, C., et al. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.735524 · Cited by 66
Simpson, H. B., Slifstein, M., Bender, J., Xu, X., Hackett, E., Maher, M. J., & Abi-Dargham, A. (2011) · Biological Psychiatry · doi:10.1016/j.biopsych.2011.06.023 · Cited by 47
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
Accelerating image registration of MRI by GPU-based parallel computation
Huang, T.-Y., Tang, Y.-W., & Ju, S.-Y. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.02.027 · Cited by 32
Oblak, A. L., Kotredes, K. P., Pandey, R. S., Reagan, A. M., Ingraham, C., Perkins, B., Lloyd, C., Baker, D., Lin, P. B., Soni, D. M., et al. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.886575 · Cited by 26
“All PET and MRI images were co-registered using a ridgedbody mutual information-based normalized entropy algorithm (Studholme et al., 1997) with 12 degrees of freedom and mapped to stereotactic mouse brain coordinates (Franklin and Paxinos, 2013) using MIM 7.”
Method
Metadata
- Authors
- Studholme, C., Hill, D. L. G., & Hawkes, D. J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 24
- Issue
- 1
- Pages
- 25-35
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1991622227
- Cited by
- 675
- References
- 18
- FWCI
- 35.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.