The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Measurement of viscoelastic properties of homogeneous soft solid using transient elastography: An inverse problem approach
Abstract
Two main questions are at the center of this paper. The first one concerns the choice of a rheological model in the frequency range of transient elastography, sonoelasticity or NMR elastography for soft solids (20–1000 Hz). Transient elastography experiments based on plane shear waves that propagate in an Agar-gelatin phantom or in bovine muscles enable one to quantify their viscoelastic properties. The comparison of these experimental results to the prediction of the two simplest rheological models indicate clearly that Voigt’s model is the better. The second question studied in the paper deals with the feasibility of quantitative viscosity mapping using inverse problem algorithm. In the ideal situation where plane shear waves propagate in a sample, a simple inverse problem based on the Helmholtz equation correctly retrieves both elasticity and viscosity. In a more realistic situation with nonplane shear waves, this simple approach fails. Nevertheless, it is shown that quantitative viscosity mapping is still possible if one uses an appropriate inverse problem that fully takes into account diffraction in solids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Self-citationShear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Self-citationIn vivo breast tumor detection using transient elastography
Bercoff, J., Chaffai, S., Tanter, M., Sandrin, L., Catheline, S., Fink, M., Gennisson, J. L., & Meunier, M. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00978-5 · Cited by 341
Self-citationA solution to diffraction biases in sonoelasticity: The acoustic impulse technique
Catheline, S., Wu, F., & Fink, M. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426907 · Cited by 282
Self-citationGelation of aqueous gelatin solutions. II. Rheology of the sol-gel transition
Djabourov, M., Leblond, J., & Papon, P. (1988) · Journal de Physique · doi:10.1051/jphys:01988004902033300 · Cited by 273
Gennisson, J.-L., Catheline, S., Chaffaı̈, S., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1579008 · Cited by 272
Self-citationTime-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citationOestreicher, H. L. (1951) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906828 · Cited by 257
Sonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203
Ultrasonic shear wave properties of soft tissues and tissuelike materials
Madsen, E. L., Sathoff, H. J., & Zagzebski, J. A. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.390158 · Cited by 171
Diffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167
Self-citationVisualizing tissue compliance with MR imaging
Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050620 · Cited by 166
The feasibility of using elastography for imaging the Poisson's ratio in porous media
Righetti, R., Ophir, J., Srinivasan, S., et al. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.10.022 · Cited by 126
Walker, W. F., & Trahey, G. E. (1994) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.308499 · Cited by 113
Houten, E. E. W. V., Weaver, J. B., Miga, M. I., Kennedy, F. E., & Paulsen, K. D. (2000) · Medical Physics · doi:10.1118/1.598861 · Cited by 74
Sack, I., Bernarding, J., & Braun, J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00474-5 · Cited by 69
Sonoelasticity imaging: results in in vitro tissue specimens.
Lee, F., Bronson, J. P., Lerner, R. M., Parker, K. J., Huang, S.-C., & Roach, D. J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887038 · Cited by 50
Cited by
Ultrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Self-citationGennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683
Self-citationShearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity
Chen, S., Urban, M., Pislaru, C., Kinnick, R., Zheng, Y., Yao, A., & Greenleaf, J. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1005 · Cited by 522
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
Self-citation
Metadata
- Authors
- Catheline, S., Gennisson, J.-L., Delon, G., Fink, M., Sinkus, R., Abouelkaram, S., & Culioli, J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2004-12-01
- Volume
- 116
- Issue
- 6
- Pages
- 3734-3741
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1987381680
- Cited by
- 409
- References
- 20
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.