Place-pitch discrimination of single- versus dual-electrode stimuli by cochlear implant users
The DOI matches its Crossref record.
Abstract
Simultaneous or near-simultaneous activation of adjacent cochlear implant electrodes can produce pitch percepts intermediate to those produced by each electrode separately, thereby increasing the number of place-pitch steps available to cochlear implant listeners. To estimate how many distinct pitches could be generated with simultaneous dual-electrode stimulation, the present study measured place-pitch discrimination thresholds for single- versus dual-electrode stimuli in users of the Clarion CII device. Discrimination thresholds were expressed as the proportion of current directed to the secondary electrode of the dual-electrode pair. For 16 of 17 electrode pairs tested in six subjects, thresholds ranged from 0.11 to 0.64, suggesting that dual-electrode stimuli can produce 2–9 discriminable pitches between the pitches of single electrodes. Some subjects demonstrated a level effect, with better place-pitch discrimination at higher stimulus levels. Equal loudness was achieved with dual-electrode stimuli at net current levels that were similar to or slightly higher than those for single-electrode stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Optogenetic stimulation of the auditory pathway
Hernandez, V. H., Gehrt, A., Reuter, K., Jing, Z., Jeschke, M., Mendoza Schulz, A., Hoch, G., Bartels, M., Vogt, G., Garnham, C. W., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci69050 · Cited by 188
“Frequency resolution can be improved using multipolar stimulation at the expense of higher power consumption (12, 13) or intraneural stimulation (at least in animals) (14).”
Berenstein, C. K., Mens, L. H. M., Mulder, J. J. S., & Vanpoucke, F. J. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e3181645336 · Cited by 178
Clinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
Noble, J. H., Gifford, R. H., Hedley-Williams, A. J., Dawant, B. M., & Labadie, R. F. (2014) · Audiology and Neurotology · doi:10.1159/000365273 · Cited by 162
“…is supported by electrical modeling simulations [Whiten, 2007] as well as the pitch discrimination tests commonly performed clinically with CIs that show that electrodes that are closer to more apical SG regions generally create lower perceived pitches [Donaldson et al., 2005].”
Current steering creates additional pitch percepts in adult cochlear implant recipients
Firszt, J. B., Koch, D. B., Downing, M., & Litvak, L. (2007) · Otology & Neurotology · doi:10.1097/01.mao.0000281803.36574.bc · Cited by 150
Self-citationSpatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95
Fine, I., & Boynton, G. M. (2015) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2014.0208 · Cited by 55
Optical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
Metadata
- Authors
- Donaldson, G. S., Kreft, H. A., & Litvak, L.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2005-08-01
- Volume
- 118
- Issue
- 2
- Pages
- 623-626
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2017339178
- Cited by
- 138
- References
- 0
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.