The DOI matches its Crossref record.
Focusing of therapeutic ultrasound through a human skull: A numerical study
Abstract
A numerical model was developed which can use digitized layer interfaces to calculate ultrasound wave absorption, diffraction, reflection, and refraction. This model was used to evaluate the feasibility of ultrasound therapy and surgery through a human skull. A digitized human skull profile was obtained from magnetic resonance (MR) images and used to calculate the ultrasound field in the brain of a volunteer from a spherically curved phased array. With no phase correction, the focus of the array was shifted and defocused. The phased array technique was used to correct focal shift, reduce side lobes, and enhance focal amplitude. The optimum source element width was estimated for each frequency to obtain a near optimium focus, and an appropriate frequency range for transskull ultrasound therapy and surgery was determined. Acoustic pressure amplitude on the skull surfaces was examined, and it was shown that the skull heating problem could be overcome. Despite high attenuation, complex interface shape, and nonuniform thickness of a human skull, a sharply focused transskull ultrasound field can be generated for noninvasive ultrasound therapy and surgery in the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Self-citationAubry, J.-F., Tanter, M., Pernot, M., Thomas, J.-L., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1529663 · Cited by 581
A non-invasive method for focusing ultrasound through the human skull
Clement, G. T., & Hynynen, K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/301 · Cited by 510
Self-citationUltrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
A review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Attenuation, scattering, and absorption of ultrasound in the skull bone
Pinton, G., Aubry, J.-F., Bossy, E., Muller, M., Pernot, M., & Tanter, M. (2011) · Medical Physics · doi:10.1118/1.3668316 · Cited by 405
Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20118 · Cited by 340
Self-citationNon-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Ultrasonic Neuromodulation Causes Widespread Cortical Activation via an Indirect Auditory Mechanism
Sato, T., Shapiro, M. G., & Tsao, D. Y. (2018) · Neuron · doi:10.1016/j.neuron.2018.05.009 · Cited by 329
Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications
Fomenko, A., Neudorfer, C., Dallapiazza, R. F., Kalia, S. K., & Lozano, A. M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2018.08.013 · Cited by 322
Treat, L. H., McDannold, N., Zhang, Y., Vykhodtseva, N., & Hynynen, K. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.04.015 · Cited by 296
Self-citation
Metadata
- Authors
- Sun, J., & Hynynen, K.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1998-09-01
- Volume
- 104
- Issue
- 3
- Pages
- 1705-1715
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2089328310
- Cited by
- 213
- References
- 0
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.