The effect of parametric variations of cochlear implant processors on speech understanding
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This study investigated the effect of five speech processing parameters, currently employed in cochlear implant processors, on speech understanding. Experiment 1 examined speech recognition as a function of stimulation rate in six Med-El/CIS-Link cochlear implant listeners. Results showed that higher stimulation rates (2100 pulses/s) produced a significantly higher performance on word and consonant recognition than lower stimulation rates (<800 pulses/s). The effect of stimulation rate on consonant recognition was highly dependent on the vowel context. The largest benefit was noted for consonants in the /uCu/ and /iCi/ contexts, while the smallest benefit was noted for consonants in the /aCa/ context. This finding suggests that the /aCa/ consonant test, which is widely used today, is not sensitive enough to parametric variations of implant processors. Experiment 2 examined vowel and consonant recognition as a function of pulse width for low-rate (400 and 800 pps) implementations of the CIS strategy. For the 400-pps condition, wider pulse widths (208 μs/phase) produced significantly higher performance on consonant recognition than shorter pulse widths (40 μs/phase). Experiments 3–5 examined vowel and consonant recognition as a function of the filter overlap in the analysis filters, shape of the amplitude mapping function, and signal bandwidth. Results showed that the amount of filter overlap (ranging from −20 to −60 dB/oct) and the signal bandwidth (ranging from 6.7 to 9.9 kHz) had no effect on phoneme recognition. The shape of the amplitude mapping functions (ranging from strongly compressive to weakly compressive) had only a minor effect on performance, with the lowest performance obtained for nearly linear mapping functions. Of the five speech processing parameters examined in this study, the pulse rate and the pulse width had the largest (positive) effect on speech recognition. For a fixed pulse width, higher rates (2100 pps) of stimulation provided a significantly better performance on word recognition than lower rates (<800 pps) of stimulation. High performance was also achieved by jointly varying the pulse rate and pulse width. The above results indicate that audiologists can optimize the implant listener’s performance either by increasing the pulse rate or by jointly varying the pulse rate and pulse width.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control Methods Used in a Study of the Vowels
Peterson, G. E., & Barney, H. L. (1952) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906875 · Cited by 2,837
Acoustic characteristics of American English vowels
Hillenbrand, J., Getty, L. A., Clark, M. J., & Wheeler, K. (1995) · The Journal of the Acoustical Society of America · doi:10.1121/1.411872 · Cited by 2,072
An Analysis of Perceptual Confusions Among Some English Consonants
Miller, G. A., & Nicely, P. E. (1955) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907526 · Cited by 1,869
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Self-citationDorman, M. F., Studdert-Kennedy, M., & Raphael, L. J. (1977) · Perception & Psychophysics · doi:10.3758/bf03198744 · Cited by 221
Self-citationSpeech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423774 · Cited by 193
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417043 · Cited by 169
Amplitude Mapping and Phoneme Recognition in Cochlear Implant Listeners
Zeng, F.-G., & Galvin, J. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00006 · Cited by 161
Temporal representations with cochlear implants.
Wilson, B. S., Finley, C. C., Lawson, D. T., & Zerbi, M. (1997) · PubMed · Cited by 130
Smits, R., ten Bosch, L., & Collier, R. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417241 · Cited by 64
Loizou, P. C., Dorman, M. F., & Powell, V. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.421248 · Cited by 44
Self-citationDorman, M. F., & Loizou, P. C. (1997) · Ear and Hearing · doi:10.1097/00003446-199704000-00007 · Cited by 28
Self-citationFu, Q., & Shannon, R. V. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.427031 · Cited by 27
Cited by
Fu, Q.-J., Chinchilla, S., & Galvin, J. J. (2004) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-004-4046-1 · Cited by 178
“…either varying the cutoff frequency of envelope extraction (Fu and Shannon 2000; Rosen 1992; Van Tasell et al. 1987; Drullman et al. 1994; Wilson et al. 1999) or by varying the rate of stimulation (Brill et al. 1997; Friesen et al. 2004; Fu and Shannon 2000; Loizou et al. 2000; Wilson et al. 1999).”
Speech dynamic range and its effect on cochlear implant performance
Zeng, F.-G., Grant, G., Niparko, J., Galvin, J., Shannon, R., Opie, J., & Segel, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1423926 · Cited by 171
Temporal considerations for stimulating spiral ganglion neurons with cochlear implants.
Boulet, J., White, M., & Bruce, I. C. (2016) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-015-0545-5 · Cited by 114
Metadata
- Authors
- Loizou, P. C., Poroy, O., & Dorman, M.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2000-08-01
- Volume
- 108
- Issue
- 2
- Pages
- 790-802
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2014938809
- Cited by
- 164
- References
- 14
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.