CoChat

Integrated photonic platform for quantum information with continuous variables

Open access

The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.

Abstract

An integrated optical chip is used for generating, manipulating, and detecting squeezed vacuum and two-mode entanglement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aat9331

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Configuration of the chip and experimental setup. Periodically poled waveguides (1, 2) are the nonclassical light sources. The squeezed vacuum states are manipulated in a reconfigurable directional coupler (DC1) for the generation of two separable squeezed states or a two-mode CV entangled state. DC2 and DC3 are used to separate the pump at ~777 nm from the signal at ~1554 nm. The rest of the network (ϕLO1, ϕLO2, DC4, and DC5) is made of the reconfigurable phase shifters and couplers of the two homodyne detectors.
Fig. 1 Configuration of the chip and experimental setup. Periodically poled waveguides (1, 2) are the nonclassical light sources. The squeezed vacuum states are manipulated in a reconfigurable directional coupler (DC1) for the generation of two separable squeezed states or a two-mode CV entangled state. DC2 and DC3 are used to separate the pump at ~777 nm from the signal at ~1554 nm. The rest of the network (ϕLO1, ϕLO2, DC4, and DC5) is made of the reconfigurable phase shifters and couplers of the two homodyne detectors.CC BY-NC · PubMed Central
Fig. 2 Generation and homodyne detection of squeezed vacuum states. (A) Measured normalized SHG efficiencies P2ω/Pω² for waveguide 1 (blue points) and waveguide 2 (red points) at T = 125°C and relative theoretical fit (solid lines). Pump and second harmonic powers are corrected for Fresnel losses at the output facet and propagation losses (see Materials and Methods). The FWHM of the fit sinc2 are ≃ 0.5 nm, consistent with a ≃ 2-cm interaction length. The waveguides have the same normalized conversion efficiency ≃ 370% W−1 at λ = 1554.45 nm. Measurements are performed in the undepleted pump regime, where the SHG power increases quadratically with pump power. The reported SHG efficiencies have a ±10% relative uncertainty, which is introduced by the error in the power calibration of the used power meters. (B) SR of DC1 (top image) and voltage applied to the LO phase shifters (bottom image) as a function of time. SR measurement is performed by injecting a 1550-nm beam into waveguide 2 and measuring the power at the first output with a photodiode. DC1 electrode is driven with a square wave with 1-kHz frequency and ±16-V amplitude. Distortion of the square signal is due to the limited bandwidth of the voltage amplifier. (C) Noise trace measured from HD1 for a 154-mW pump power. Pump power is measured at the output of the device and corrected for Fresnel losses at the output facet and propagation losses inside the waveguides. Noise variance is calculated on time intervals of 4-μs duration and averaged over 40 sequential traces. Sampling rate is 50 MSPS (mega-sample-per-second). (D) Measured squeezing and antisqueezing levels as a function of pump power for waveguide 1 (blue squares) and waveguide 2 (red circles). Solid lines are the fits made with the function of Eq. 1. Error on the measured noise levels is ±0.04 dB. Pump powers are measured at the output of the device and corrected for Fresnel losses at the output facet and propagation losses inside the waveguides. Pump wavelength is λP = 1554.55/2 nm for waveguide 1 and λP = 1554.35/2 nm for waveguide 2.
Fig. 2 Generation and homodyne detection of squeezed vacuum states. (A) Measured normalized SHG efficiencies P2ω/Pω² for waveguide 1 (blue points) and waveguide 2 (red points) at T = 125°C and relative theoretical fit (solid lines). Pump and second harmonic powers are corrected for Fresnel losses at the output facet and propagation losses (see Materials and Methods). The FWHM of the fit sinc2 are ≃ 0.5 nm, consistent with a ≃ 2-cm interaction length. The waveguides have the same normalized conversion efficiency ≃ 370% W−1 at λ = 1554.45 nm. Measurements are performed in the undepleted pump regime, where the SHG power increases quadratically with pump power. The reported SHG efficiencies have a ±10% relative uncertainty, which is introduced by the error in the power calibration of the used power meters. (B) SR of DC1 (top image) and voltage applied to the LO phase shifters (bottom image) as a function of time. SR measurement is performed by injecting a 1550-nm beam into waveguide 2 and measuring the power at the first output with a photodiode. DC1 electrode is driven with a square wave with 1-kHz frequency and ±16-V amplitude. Distortion of the square signal is due to the limited bandwidth of the voltage amplifier. (C) Noise trace measured from HD1 for a 154-mW pump power. Pump power is measured at the output of the device and corrected for Fresnel losses at the output facet and propagation losses inside the waveguides. Noise variance is calculated on time intervals of 4-μs duration and averaged over 40 sequential traces. Sampling rate is 50 MSPS (mega-sample-per-second). (D) Measured squeezing and antisqueezing levels as a function of pump power for waveguide 1 (blue squares) and waveguide 2 (red circles). Solid lines are the fits made with the function of Eq. 1. Error on the measured noise levels is ±0.04 dB. Pump powers are measured at the output of the device and corrected for Fresnel losses at the output facet and propagation losses inside the waveguides. Pump wavelength is λP = 1554.55/2 nm for waveguide 1 and λP = 1554.35/2 nm for waveguide 2.CC BY-NC · PubMed Central
Fig. 3 Generation and characterization of CV entanglement. (A) SR of DC1 (top image) and voltage applied to phase shifters ϕLO1 (green trace, bottom image) and ϕLO2 (red trace, bottom image) as a function of time. SR measurement is performed by injecting a 1550-nm beam into waveguide 2 and measuring the power at the first output with a photodiode. DC1 electrode is driven with a square wave at 1-kHz frequency and ±5.5-V amplitude. Scanning frequency is 1 kHz for ϕLO1 and 10 kHz for ϕLO2. (B) Noise levels measured from HD1 (blue trace) and HD2 (red trace) when the pump beams are in phase. (C) Noise levels measured from HD1 (blue trace) and HD2 (red trace) when the pump beams are out of phase. (D) Noise levels of summed quadratures 〈Δ²(X^1+X^2)〉 (green trace) and subtracted quadratures 〈Δ²(X^1−X^2)〉 (red trace) when the pump beams are out of phase. Noise variance is calculated on time intervals of 2.5-μs duration and averaged over 10 sequential traces. Sampling time is 20 ns. Measurements are performed with two pump beams with P = 122 mW and λP = 1554.45/2 nm.
Fig. 3 Generation and characterization of CV entanglement. (A) SR of DC1 (top image) and voltage applied to phase shifters ϕLO1 (green trace, bottom image) and ϕLO2 (red trace, bottom image) as a function of time. SR measurement is performed by injecting a 1550-nm beam into waveguide 2 and measuring the power at the first output with a photodiode. DC1 electrode is driven with a square wave at 1-kHz frequency and ±5.5-V amplitude. Scanning frequency is 1 kHz for ϕLO1 and 10 kHz for ϕLO2. (B) Noise levels measured from HD1 (blue trace) and HD2 (red trace) when the pump beams are in phase. (C) Noise levels measured from HD1 (blue trace) and HD2 (red trace) when the pump beams are out of phase. (D) Noise levels of summed quadratures 〈Δ²(X^1+X^2)〉 (green trace) and subtracted quadratures 〈Δ²(X^1−X^2)〉 (red trace) when the pump beams are out of phase. Noise variance is calculated on time intervals of 2.5-μs duration and averaged over 10 sequential traces. Sampling time is 20 ns. Measurements are performed with two pump beams with P = 122 mW and λP = 1554.45/2 nm.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 170

Metadata

Authors
Lenzini, F., Janousek, J., Thearle, O., Villa, M., Haylock, B., Kasture, S., Cui, L., Phan, H.-P., Dao, D. V., Yonezawa, H., Lam, P. K., Huntington, E. H., & Lobino, M.
Affiliations
  • Griffith University (AU)
  • Centre for Quantum Computation and Communication Technology and Research School of Engineering, The Australian National University, Canberra, ACT 2601, Australia.
  • Australian National University (AU)
  • Tianjin University (CN)
  • Centre for Quantum Computation and Communication Technology (AU)
Corresponding author
Lobino, Mirko
Venue
Science Advances
Published
2018-12-07
Volume
4
Issue
12
Pages
eaat9331-eaat9331
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2798867696
Cited by
159
References
43
Citations by year
2026: 13 · 2025: 23 · 2024: 19 · 2023: 13 · 2022: 19 · 2021: 26 · 2020: 26 · 2019: 19
FWCI
10.00
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Iris (University of Trento) (submittedVersion, other-oa)
  • ANU Open Research (Australian National University) (submittedVersion, cc-by-nc)
  • Griffith Research Online (submittedVersion, cc-by-nc)
  • arXiv (Cornell University)
Funders
Centre of Excellence for Quantum Computation and Communication Technology, Australian Research Council (CE170100012)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
Keywords
integrated photonics, continuous-variable quantum information, quantum computing, nonlinear optical properties

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.