Abstract
The continuous monitoring of hemodynamics attainable with wireless implantable devices would improve the treatment of vascular diseases. However, demanding requirements of size, wireless operation, and compatibility with endovascular procedures have limited the development of vascular electronics. Here, we report an implantable, wireless vascular electronic system, consisting of a multimaterial inductive stent and printed soft sensors capable of real-time monitoring of arterial pressure, pulse rate, and flow without batteries or circuits. Developments in stent design achieve an enhanced wireless platform while matching conventional stent mechanics. The fully printed pressure sensors demonstrate fast response times, high durability, and sensing at small bending radii. The device is monitored via inductive coupling at communication distances notably larger than prior vascular sensors. The wireless electronic system is validated in artery models, while minimally invasive catheter implantation is demonstrated in an in vivo rabbit study. Overall, the vascular system offers an adaptable framework for comprehensive monitoring of hemodynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2020 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Delling, F. N., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000757 · Cited by 9,175
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Ibrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Metadata
- Authors
- Herbert, R., Lim, H.-R., Rigo, B., & Yeo, W.-H.
- Venue
- Science Advances
- Published
- 2022-05-13
- Volume
- 8
- Issue
- 19
- Pages
- eabm1175-eabm1175
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W4280514966
- Cited by
- 165
- References
- 7
- FWCI
- 7.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics. https://app.cochat.ai/papers/10.1126/sciadv.abm1175
- The paper
- Herbert, R., Lim, H.-R., Rigo, B., & Yeo, W.-H. (2022). Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics. Science Advances. https://doi.org/10.1126/sciadv.abm1175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.