The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency
Open accessAbstract
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






![Fig. 7. Invasiveness evaluation in human placenta blood vessels. (A) Setup of the invasiveness evaluation test. We choose four segments from the superficial blood vessels of the human placenta. In segment I, the proposed microcatheter contacts the blood vessel’s inner wall and is rotational actuated for 30 min. In segment II, the proposed microcatheter contacts the blood vessel’s inner wall and is repeatedly inserted 100 times. In segment III, a commercial guidewire is inserted into the blood vessel with tip contact on the vessel wall 100 times. Segment IV is blank control. (B to E) Example images of the histological analysis that show the physical impact on the endothelial cell layer and the inner vessel wall. The black arrows show the cell layer detachments, and the dashed line shows the torn and missing cell layer [rotational actuation and contact frictional insertion (commercial)].](https://figures.cochat.ai/paper-figures/ca12f82f4a7643ddbe1ba23aa17d2627/a-magnetically-actuated-microcatheter-with-soft-rotatable-tip-for-enhanced-figure-7.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Soft robots, steerable catheters, and magnetic microbots allow non-traumatic vascular navigation, targeted drug or clot therapies, and on-demand embolization [153,155,156,157,158,159,160] with MRI-guided magnetic navigation enhancing visualization and safety [17,155,156].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saver, J. L. (2006) · Stroke · doi:10.1161/01.str.0000196957.55928.ab · Cited by 2,181
Small vessel disease: mechanisms and clinical implications
Wardlaw, J. M., Smith, C., & Dichgans, M. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30079-1 · Cited by 1,777
De Luca, G., Suryapranata, H., Ottervanger, J. P., & Antman, E. M. (2004) · Circulation · doi:10.1161/01.cir.0000121424.76486.20 · Cited by 1,542
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Saver, J. L., Chapot, R., Agid, R., Hassan, A. E., Jadhav, A. P., Liebeskind, D. S., Lobotesis, K., Meila, D., Meyer, L., Raphaeli, G., et al. (2020) · Stroke · doi:10.1161/strokeaha.120.028956 · Cited by 456
Telerobotic neurovascular interventions with magnetic manipulation
Kim, Y., Genevriere, E., Harker, P., Choe, J., Balicki, M., Regenhardt, R. W., Vranic, J. E., Dmytriw, A. A., Patel, A. B., & Zhao, X. (2022) · Science Robotics · doi:10.1126/scirobotics.abg9907 · Cited by 422
Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review
Rafii-Tari, H., Payne, C. J., & Yang, G.-Z. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0946-8 · Cited by 288
Thermal diffusion in liquid mixtures and polymer solutions
Wiegand, S. (2004) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/16/10/r02 · Cited by 280
Sperm Micromotors for Cargo Delivery through Flowing Blood
Xu, H., Medina-Sánchez, M., Maitz, M. F., Werner, C., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.9b07851 · Cited by 264
Ferromagnetic soft catheter robots for minimally invasive bioprinting
Zhou, C., Yang, Y., Wang, J., Wu, Q., Gu, Z., Zhou, Y., Liu, X., Yang, Y., Tang, H., Ling, Q., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25386-w · Cited by 242
Self-citation
Cited by
Micro/Nanorobots for Combating Brain Disorders: Challenges, Advances, and Perspectives
Zhang, Q., & Sun, D. B. (2025) · Advanced Science · doi:10.1002/advs.202516592 · Cited by 15
Bio-inspired Magnetic Helical Miniature Robots: Mechanisms, Control and Biomedical Applications
Zhu, A., Li, Y., Zheng, Y., & Yang, L. (2025) · Journal of Bionic Engineering · doi:10.1007/s42235-025-00795-5 · Cited by 13
Self-citationMagnetic slippery microcatheter with artificial cilia for low-friction interventions
Yang, S., Shen, J., He, J., Xia, Z., Zhang, Y., & Wang, B. (2025) · Science Advances · doi:10.1126/sciadv.adw9926 · Cited by 10
Biophysics-informed design of biohybrid microrobots
Quan, X., Sun, B., Song, X., & Zhang, L. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00416-8 · Cited by 10
Self-citationStable magnetic soft structures
Wang, H., Zhang, Y., Liu, X., Li, H., Chen, X., Cao, Z.-Q., Luo, Q., Ren, Z., & Hu, W. (2025) · Science Advances · doi:10.1126/sciadv.adz4952 · Cited by 5
Self-citationMagnetic soft robots in medicine: material and structural designs for organ-specific applications
Chen, Z., Yang, S., Law, J., Du, X., & Sun, Y. (2026) · Soft Science · doi:10.20517/ss.2025.97 · Cited by 5
A survey on magnetically driven continuum robots for biomedical application
Li, P., Chen, Y. R., Lin, X., Ye, C., Zhang, J., Fang, D., & Liang, C. (2025) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2025.105316 · Cited by 3
Nonlinear bending of hard-magnetic soft guidewire with mechanical symmetry-breaking
Song, W., Fu, K., & Lyu, Z. (2025) · Thin-Walled Structures · doi:10.1016/j.tws.2025.114144 · Cited by 3
Yin, H., Li, Y., Wu, G., & Guo, Y. (2026) · Responsive materials · doi:10.1002/rpm2.70055 · Cited by 4
Physics-constrained learning framework for trustworthy microrobot navigation autonomy
Zhao, J., Li, Y., Sun, Y. W., Wang, Y., Zhu, A., Shi, D., Li, X., Chen, Q., Yuan, C., Ferreira, A., et al. (2026) · Science Advances · doi:10.1126/sciadv.aef7326 · Cited by 3
Self-citationJiang, Z., Wang, S., Xiang, Q., Wang, Y., Fu, S., Deng, H., He, Q., Wang, Y., Mao, Z., Liu, C., et al. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102711 · Cited by 2
Bridging sensation and actuation: From fundamental architectures to adaptive systems
Huang, Y., Zhu, W., Yin, C., Hu, S., Zhou, J., Guo, Z., Zhang, Q., Zhang, G., & Deng, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.173685 · Cited by 2
Chitosan and polycaprolactone blended PDMS coatings improve biocompatibility of magnetic elastomers
Mystkowska, J., Łysik, D., Czerniakiewicz, A., Piktel, E., Deptuła, P., Bucki, R., Perkowski, D. M., Augustyniak, J., & Mystkowski, A. (2026) · Scientific Reports · doi:10.1038/s41598-026-40085-6 · Cited by 2
Cross‐Scale Hierarchical Targeted Delivery System Based on Small‐Scale Magnetic Robots
Zhou, J., Chen, Z., Ma, Y., Tang, Z., & Wang, Q. (2026) · Advanced Robotics Research · doi:10.1002/adrr.202500187 · Cited by 2
Self-citationBjerknes force-driven acoustic responsive materials for wireless soft robotics
Chen, K., Deng, Z., Kang, Y., Luo, Y., Wei, X., Wang, X., Liu, X., Zhang, W., & Ma, Z. (2026) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2026.111958 · Cited by 2
Self-citationPalantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
“Soft robots, steerable catheters, and magnetic microbots allow non-traumatic vascular navigation, targeted drug or clot therapies, and on-demand embolization [153,155–160] with MRI-guided magnetic navigation enhancing visualization and safety [17,155,156].”
Kim, J., & Kim, T. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202502199 · Cited by 1
Design and Actuation of a Multipole Ring Magnet for Navigating Endovascular Magnetic Instruments
Raub, J., Pancaldi, L., Deschwanden, L. V., & Sakar, M. S. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3648609 · Cited by 1
Buckling of magneto-active soft hyperelastic tubes: Geometric counter-intuition and mode transition
Li, H.-J., Song, X.-T., Tang, X.-Y., Zhang, T., & Xie, Y.-X. (2026) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2026.104529 · Cited by 1
Zhang, Z., Zeng, Z., Zhang, J., Yu, L., He, R., Han, B., & Ma, Z. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c01695 · Cited by 1
Soft robotic devices for cardiovascular medicine
Ji, X.-Y., Zhu, J.-Q., Wu, K., Wang, L., Xiong, T., Zhang, L., & Chen, M. L. (2026) · Nature Reviews Cardiology · doi:10.1038/s41569-026-01287-7 · Cited by 5
Self-citationMicro/Nanorobotic Systems for Imaging-Guided Closed-Loop Thrombus Recanalization
He, J., Xia, Z., Liao, L., Li, X., Wu, X., Shen, J., Wang, Q., & Wang, B. (2026) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0592 · Cited by 1
Self-citationWu, H., Wu, C., Wang, H., Han, J., & Qin, Y. (2026) · Smart Materials and Structures · doi:10.1088/1361-665x/ae7b95 · Cited by 1
A ciliated intravascular soft millirobot for multimodal in-flow collective manipulation
Wang, Y., Li, Y., Xie, L., Fang, K., Wei, C., Duan, F., & Yu, J. (2026) · Science Advances · doi:10.1126/sciadv.aeg3333 · Cited by 1
A Superlubricated Magnetically Steerable Microcatheter with Integrated Optical and Fluidic Channels
Du, Y., He, R., Li, L., Wang, H., Ma, Z., & Han, B. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202500131 · Cited by 2
Lyu, C., Xu, Q., Li, S., Chen, E. J., Zhu, W., Ren, H., & Ding, W. (2025) · MedMat. · doi:10.1097/mm9.0000000000000031
Al-momani, A. N., Iqbal, A., Yanto, D. H. Y., Karimah, S. N., Khairuddean, M., Jazzazi, T. M. A., Phoon, S. C., Haisen, L., Abdullah, M., Putra, A. B. N., et al. (2026) · Chemistry Africa · doi:10.1007/s42250-025-01572-x
Microrobotic Catheterization of the Ophthalmic Artery for Targeted Treatment of Retinoblastoma
Banach, A., Krichen, M., Raub, J., Stathopoulos, C., Bartolini, B. M., & Sakar, M. S. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.202500945
Liu, L., Yang, Z., Han, X., Li, Z., Jiao, Y., & Cui, Y. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3670533
A review of magnetic-driven continuum robots applied to the biomedical field
Zhang, T., Shang, W., & Shen, Y. (2026) · Scientia Sinica Technologica · doi:10.1360/sst-2025-0455
Optimization of Magnetic Milli‐Spinner for Robotic Endovascular Intervention
Lu, L., Higgins, L., Bernardo, J. S., & Zhao, R. R. (2026) · Advanced Robotics Research · doi:10.1002/adrr.70121
Sun, X., Wu, T., Chen, F., Yu, Q., Zhang, B., Jiang, L., & Zhang, Y. (2026) · Actuators · doi:10.3390/act15060289
A Review of Magnetically Controlled Continuum Robots: Principles, Classification, and Applications
Zhang, M., Song, L., Yu, W., An, X., Ren, S., Zhang, J., Wang, S., Li, J., Li, J. S., Li, Y., et al. (2026) · Magnetochemistry · doi:10.3390/magnetochemistry12060066
Self-citationZhang, W., Li, R., Niu, H., Fan, Y., Yuan, M., Niu, G., Wang, L., Kang, Y., Xia, D., Yu, X., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.76985
Self-citationZhao, H., Chen, Z., Striggow, F., Castellanos‐Robles, D., & Medina‐Sánchez, M. (2026) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss70227.2026.11655676
Gunawardane, P. D. S. H., Zesiro, G. E., Zhou, H., Alıcı, G., & Chiao, M. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71286
Actuation, sensing, and integration in soft robotics: principles, progress, and future trends
Bu, X., Yao, S., Zhang, C., Gao, S., Lin, Y., Zhang, Q., Tian, Y., Li, L., & Jin, T. (2026) · Intelligence & Robotics · doi:10.20517/ir.2026.31
Magnetically Actuated Continuum Robots: From Engineering to Clinical Translation
Yang, Z., Jiao, Y., Niu, M., Cui, Y., Yang, L., Xu, Q., & Zhang, L. (2026) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0745
Self-citationLu, W., He, Q., Zhu, G., Wang, Y., Xiao, T., Fu, S., Zhuang, J., & Liu, C. (2026) · Advanced Functional Materials · doi:10.1002/adfm.79346
Flash minimization in catheter tip forming through core design and pin–tube arrangement
Jang, B., Kim, T., & Park, K. (2026) · Micro and Nano Systems Letters · doi:10.1186/s40486-026-00269-1
Metadata
- Authors
- Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., Ko, H., Liu, X., Wang, L., Ip, B. Y. M., Leung, T. W. H., & Zhang, L.
- Affiliations
- Chinese University of Hong Kong (HK)
- Hong Kong Polytechnic University (HK)
- Nanyang Technological University (SG)
- University of Science and Technology of China (CN)
- Corresponding author
- Yang, Lidong
- Ip, Bonaventure Yiu Ming
- Leung, Thomas Wai Hong
- Zhang, Li
- ORCID
- Venue
- Science Advances
- Published
- 2025-06-20
- Volume
- 11
- Issue
- 25
- Pages
- eadv1682-eadv1682
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC13108821
- OpenAlex
- W4411472631
- Cited by
- 36
- References
- 79
- Citations by year
- 2026: 26 · 2025: 10
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Science Advances (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion, cc-by)
- Topics
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Keywords
- endovascular access, thrombolysis, clot retrieval, active steering, soft robotics, microcatheterization, rabbit model
- MeSH terms
- Animals, Equipment Design, Female, Humans, Pregnancy, Rabbits, Thrombosis, Phantoms, Imaging, Endovascular Procedures, Catheters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.