The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Using Selective Withdrawal to Coat Microparticles
Abstract
We report a method that uses the process of selective withdrawal of one fluid through a second immiscible fluid to coat small particles with polymer films. Fluid is withdrawn through a tube with its orifice slightly above a water-oil interface. Upon increasing the flow rate, there is a transition from a state where only oil is withdrawn to a state where the water, containing the particles to be coated and appropriate prepolymer reagents, is entrained in a thin spout along with the oil. The entrained particles eventually cause the spout interface to break, producing a thin coat of controllable thickness around each particle, which can be subsequently polymerized using chemical reagents, light, or heat. This method allows flexibility in the chemical composition and thickness of the conformal coatings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Cited by
Bonn, D., Eggers, J., Indekeu, J., Meunier, J., & Rolley, E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.739 · Cited by 2,894
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Colloidosomes: Selectively Permeable Capsules Composed of Colloidal Particles
Dinsmore, A. D., Hsu, M. F., Nikolaides, M. G., Marquez, M., Bausch, A. R., & Weitz, D. A. (2002) · Science · doi:10.1126/science.1074868 · Cited by 2,061
Eggers, J., & Villermaux, E. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/3/036601 · Cited by 1,827
Micro/Nano encapsulation via electrified coaxial liquid jets
Loscertales, I. G., Barrero, A., Guerrero, I., Cortijo, R., Marquez, M., & Gañán-Calvo, A. M. (2002) · Science · doi:10.1126/science.1067595 · Cited by 1,017
Dripping to Jetting Transitions in Coflowing Liquid Streams
Utada, A. S., Fernandez-Nieves, A., Stone, H. A., & Weitz, D. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.094502 · Cited by 965
Polymer hollow particles with controllable holes in their surfaces
Hyuk Im, S., Jeong, U., & Xia, Y. (2005) · Nature Materials · doi:10.1038/nmat1448 · Cited by 547
Gokmen, M. T., & Du Prez, F. E. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.07.006 · Cited by 492
Small‐scale free surface flows with breakup: Drop formation and emerging applications
Basaran, O. A. (2002) · AIChE Journal · doi:10.1002/aic.690480902 · Cited by 478
An Axisymmetric Flow‐Focusing Microfluidic Device
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005) · Advanced Materials · doi:10.1002/adma.200401738 · Cited by 370
McCann, J. T., Marquez, M., & Xia, Y. (2006) · Nano Letters · doi:10.1021/nl0620839 · Cited by 357
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Double emulsions prepared by two–step emulsification: History, state-of-the-art and perspective
Ding, S., Serra, C. A., Vandamme, T. F., Yu, W., & Anton, N. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.12.037 · Cited by 281
Micro- and nanoparticles via capillary flows
Barrero, A., & Loscertales, I. G. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110245 · Cited by 219
Future of the Particle Replication in Nonwetting Templates (PRINT) Technology
Xu, J., Wong, D. H. C., Byrne, J. D., Chen, K., Bowerman, C., & DeSimone, J. M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201209145 · Cited by 208
Metadata
- Authors
- Cohen, I., Li, H., Hougland, J. L., Mrksich, M., & Nagel, S. R.
- Venue
- Science
- Published
- 2001-04-13
- Volume
- 292
- Issue
- 5515
- Pages
- 265-267
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2003322831
- Cited by
- 166
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.