Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A femtosecond laser–based optical frequency synthesizer is referenced to an optical standard, and we use it to demonstrate the generation and control of the frequency of electromagnetic fields over 100 terahertz of bandwidth with fractional uncertainties approaching 1 part in 10 19 . The reproducibility of this performance is verified by comparison of different types of femtosecond laser–based frequency synthesizers from three laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They compared the different”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is due to the fact that the time and frequency science develop very quickly, and clocks or time-keeping systems and portable clocks with the stability better than 1 × 10 -18 might be available in the near future [22,27].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Allan, D. W. (1987) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/t-uffc.1987.26997 · Cited by 853
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Absolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Accurate measurement of large optical frequency differences with a mode-locked laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Optics Letters · doi:10.1364/ol.24.000881 · Cited by 418
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Research works printed but not linked: 3
- P. Gill Ed. Proceedings of the 6th Symposium on Frequency Standards and Metrology (World Scientific Singapore 2002).
- A. Sen Gupta, D. Popovic, F. L. Walls, in Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum (EFTF) and the IEEE International Frequency Control Symposium (FCS), Besançon, France, 13 to 16 April 1999 (IEEE, Piscataway, NJ, 1999), pp. 615–619.
- A. Bartels, S. A. Diddams, T. M. Ramond, L. Hollberg, Opt. Lett.28, 663 (2002).
Cited by
Items 201–300 of 325
Cai, Y., Pan, R., Hu, X., Ye, F., Zhang, W., Zhao, W., & Wang, Y. (2020) · Optical Engineering · doi:10.1117/1.oe.59.2.026107 · Cited by 3
“In particular, in the field of optical clock research and application, an important step is the measurement of the absolute frequency of the laser used in the optical clock and intercomparison of optical frequency standards.(19) This requires that the spectral range of the optical frequency comb cover the visible rang…”
BackgroundGeneration and research progress of femtosecond optical frequency combs in extreme ultraviolet
Li, Z., Liu, H., Wang, H., Wang, G.-Y., Jiang, J., Han, H.-N., Zhu, J., & Wei, Z. (2020) · Acta Physica Sinica · doi:10.7498/aps.69.20200851 · Cited by 3
Quantum-limited phase-matching effect in a Λ -type laser system
Yu, D., & Chen, J. (2011) · Physical Review A · doi:10.1103/physreva.83.063846 · Cited by 3
Dong, J., & Dong, B. Y. (2011) · Physics Essays · doi:10.4006/1.3579492 · Cited by 3
Optical phase-noise dynamics of Titanium:sapphire optical frequency combs
Quraishi, Q. S., Diddams, S. A., & Hollberg, L. W. (2014) · Optics Communications · doi:10.1016/j.optcom.2014.01.030 · Cited by 3
“When OFC’s are referenced to stable atomic transitions, the OFC provides a bridge to evaluate relative instabilities based on different atomic frequency standards Diddams et al. (2001); Gerginov et al. (2006); Ma et al. (2004); Newbury (2011).”
BackgroundResultSelf-citationOptical frequency comb comparison between optical clock mode and optical frequency synthesizer mode
Kim, E. B., Park, C. Y., Yu, D., Park, S. E., & Lee, W. (2011) · Optical Engineering · doi:10.1117/1.3533731 · Cited by 3
Optical atomic clocks: a revolution in performance
Hollberg, L. W. (2005) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2005.202086 · Cited by 3
Self-citationLiang, W. G. (2008) · doi:10.7907/yhbf-kw11 · Cited by 3
PRECISION SPECTROSCOPY OF HYDROGEN AND FEMTOSECOND LASER FREQUENCY COMBS
Udem, T., Fendel, P., Fischer, M. D., Kolachevsky, N., Alnis, J., Zimmermann, M., Gohle, C., HERRMANN, M., Holzwarth, R., & Hänsch, T. W. (2005) · Laser Spectroscopy · doi:10.1142/9789812701473_0004 · Cited by 3
Metrology of Time and Frequency
Arias, E. F., & Bauch, A. (2010) · Wiley eBooks · doi:10.1002/3527600434.eap703 · Cited by 3
A long optical cavity for sub-Hertz laser spectroscopy
Amairi Ep Pyka, S. (2014) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/8216 · Cited by 6
“It is a reliable tool for the comparison optical frequencies with uncertainties approaching the 10−19 level [125] owing to the phase locks between all involved frequencies.”
BackgroundLazarev, V. A., Alexander, K., Dvoretskiy, D. A., Sazonkin, S. G., Alexey, P., Stanislav, L., Shelestov, D. A., Valeriy, K., Alexey, K., & Gubin, M. A. (2015) · Frontiers in Optics · doi:10.1364/fio.2015.fw3c.2 · Cited by 2
Tests of Theory in Rydberg States of One-Electron Ions
Tan, J. N., & Mohr, P. J. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_11 · Cited by 4
Toward an optical frequency comb with relative frequency uncertainty at 10−21-level
Inaba, H., Nakajima, Y., Iwakuni, K., Hosaka, K., Onae, A., Yasuda, M., Akamatsu, D., & Hong, F.-L. (2012) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2012.cth4a.6 · Cited by 2
“In these results, 1 × 10 [4] is the top data, which guarantee comb’s uncertainty limit at present.”
BackgroundInterferometric selection of frequency comb modes
Perrella, C., Light, P. S., Anstie, J. D., Baynes, F. N., & Luiten, A. N. (2013) · Applied Physics B · doi:10.1007/s00340-013-5471-9 · Cited by 2
Wei, H., Wu, X., Zhou, L., Zhang, J., & Li, Y. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.999955 · Cited by 2
Leonov, S. O., Lazarev, V. A., Voropaev, V. S., Tarabrin, M. K., Karasik, V. E., & Krylov, A. A. (2017) · Photonics & Electromagnetics Research Symposium - Spring (PIERS-Spring) · doi:10.1109/piers.2017.8262005 · Cited by 2
Absolute frequency comb comparisons and the measurement of optical atomic clock transitions
Leopardi, H., Davila-Rodriguez, J., Sherman, J. A., Quinlan, F., Diddams, S. A., & Fortier, T. M. (2018) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2018.sm1l.4 · Cited by 2
“As the characterization of optical frequency combs has been critical in identifying and minimizing the synthesis errors added in the measurement of optical frequencies [4, 5, 6], we focus on the role and performance of the optical frequency comb (OFC) in the inter-comparison measurements of difference frequencies acro…”
BackgroundSelf-citationYin, J., Dong, T., Su, Y., Cao, G., Zhou, Y., & Xu, K. (2019) · Second Symposium on Novel Technology of X-Ray Imaging · doi:10.1117/12.2524645 · Cited by 2
Farjallah, M., El-Korek, N., Korek, M., & Berriche, H. (2020) · The European Physical Journal D · doi:10.1140/epjd/e2020-10291-4 · Cited by 2
Monte Carlo Simulation for the Frequency Comb Spectrum of an Atom Laser
Schelle, A. (2023) · Quanta · doi:10.12743/quanta.v12i1.243 · Cited by 3
Lim, J. (2011) · K-State Research Exchange (Kansas State University) · Cited by 2
Comparison of Fiber-Based Frequency Comb and Ti:Sapphire-Based Frequency Comb
Lee, W.-K., Kim, E. B., Yee, D.-S., Suh, H.-S., Park, C. Y., Yu, D.-H., & Park, S. E. (2007) · Journal of the Optical Society of Korea · doi:10.3807/josk.2007.11.3.124 · Cited by 2
Real-time absolute distance measurement by comb-based generation of multiple wavelengths
Hyun, S., Kim, Y., Chun, B. J., & Kim, S. (2012) · International Journal of Nanomanufacturing · doi:10.1504/ijnm.2012.051107 · Cited by 1
“The stabilised comb allows continuous-wave laser sources to be calibrated so that the wavelength used for distance measurement can be precisely known with reference to the uncertainty of the atomic clock used for the time standard (Jones et al., 2002; Jost et al., 2002; Ma et al., 2004; Kim, 2009; Kim et al., 2008, 20…”
MethodEinstein Lecture – Passion for precision*
Hänsch, T. W. (2006) · Annalen der Physik · doi:10.1002/andp.20065180902 · Cited by 1
Wei, D., & Miura, T. (2023) · Results in Optics · doi:10.1016/j.rio.2023.100422 · Cited by 1
Principles of Optical Fiber Pulsed Lasers and Their Advanced Applications
Zhang, W. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1010288 · Cited by 1
Frequency stability measurement of laser by using two independent tunable lasers
Wang, W., Liu, J., Sun, W., Wang, W., & Zhu, N. (2015) · International Symposium on Next-Generation Electronics · doi:10.1109/isne.2015.7132001 · Cited by 1
McCarthy, D. D., & Seidelmann, P. K. (2009) · Wiley eBooks · doi:10.1002/9783527627943.ch11 · Cited by 1
Optical clocks and frequency synthesis using femtosecond lasers
Diddams, S. A. (2004) · IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS) · doi:10.1109/leos.2004.1363341 · Cited by 1
Self-citationCaraquitena, J., Jiang, Z. L., Leaird, D. E., & Weiner, A. M. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.26.000089 · Cited by 1
Dvoretskiy, D. A., Lazarev, V. A., Voropaev, V. S., Rodnova, Z. N., Sazonkin, S. G., Leonov, S. O., Karasik, V. E., & Krylov, A. A. (2015) · Advanced Solid-State Lasers · doi:10.1364/assl.2015.atu2a.34 · Cited by 1
Octave-Spanning Comb Generation and Optical Frequency Measurement Using Mode-Locked Fiber Lasers
Inaba, H., Nakajima, Y., Minoshima, K., Hong, F.-L., Onae, A., BROWN, N., Wouters, M. J., Warrington, B., & Matsumoto, H. (2007) · The Review of Laser Engineering · doi:10.2184/lsj.35.622 · Cited by 1
Gereration of microwaves with ultra-low phase-noise from an optical clock
Hollberg, L. W., Diddams, S. A., Bartels, A., McFerran, J. J., Ivanov, E. N., Wilpers, G., Oates, C. W., Oskay, W. H., & Bergquist, J. (2005) · International Topical Meeting on Microwave Photonics · doi:10.1109/mwp.2004.1412140 · Cited by 1
Self-citationModular communications and software-defined networks for aerospace applications
Lyke, J., Peters, C., Pham, K. D., Fronterhouse, D. S., & Hannon, M. (2019) · Open Architecture/Open Business Model Net-Centric Systems and Defense Transformation · doi:10.1117/12.2519918 · Cited by 1
Gain-nonlinearity-induced tunable phonon sideband spectrum and frequency comb
Zhang, M., Zheng, A., & Zhang, G. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.401247 · Cited by 1
Observation of transitions in strontium triplet state and its application in optical clock
Feng, G., Ye-Bing, W., Xiao, T., Xu, P., & Chang, H. (2012) · Acta Physica Sinica · doi:10.7498/aps.61.173201 · Cited by 1
Mitaki, M., & Sugiyama, K. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/abd86c · Cited by 1
Hänsch, T. W., & Picqué, N. (2012) · Springer eBooks · doi:10.1007/978-3-642-19409-2_17 · Cited by 3
Xiang, X., Zhang, Z., Wang, S., Wang, M., Liu, T., Dong, R., Han, H., Zhang, S., & Wei, Z. (2018) · Journal of Physics Communications · doi:10.1088/2399-6528/aab63d · Cited by 2
(2007) · Springer eBooks · doi:10.1007/978-3-540-45158-7_1 · Cited by 1
Kolpakov, S. A., Sergeyev, S. V., Loika, Y., Tarasov, N., Kalashnikov, V. L., & Agrawal, G. P. (2015) · Aston Publications Explorer (Aston University) · doi:10.48550/arxiv.1508.05933 · Cited by 1
“Evolution of the laser SOPs and population of the first excited level in Er 3+ doped active medium was modelled using the following equations derived from the vector theory developed by Sergeyev and co-workers in 28,29 : (1) Here time and length are normalised to the round trip and cavity length respectively; Si (i=0,…”
BackgroundInfluentialLow-drift and low-jitter microwave signal synthesis from mode-locked lasers
Kim, J., & Käertner, F. X. (2008) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2008.4623040 · Cited by 1
“Optical atomic clocks [1,2] can generate ultra-low-noise microwave signals with sub-femtosecond short-term (~1 second time scale) timing jitter [3].”
BackgroundFrequency comb dynamics of a solitonic fiber laser: theory
Newbury, N. R., & Washburn, B. R. (2005) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2005.202313 · Cited by 1
Photoassociation Spectroscopy of Cold Alkaline Earth Atoms near the Intercombination Line
Tiesinga, E., Ciuryło, R., Kotochigova, S., & Julienne, P. S. (2005) · Quantum Electronics and Laser Science Conference · doi:10.1109/qels.2005.1549146 · Cited by 1
Infrared frequency comb for frequency metrology based on a tunable repetition rate fiber laser
Washburn, B. R., Diddams, S. A., Newbury, N. R., Nicholson, J. W., Feder, K. S., Westbrook, P. S., & Jørgensen, C. G. (2004) · Symposium on Optical Fiber Measurements (SOFM) · doi:10.1109/sofm.2004.183464 · Cited by 1
Self-citationTesting the Stability of the Fine Structure Constant in the Laboratory
Kolachevsky, N., Matveev, A., Alnis, J., Parthey, C. G., Steinmetz, T., Wilken, T., Holzwarth, R., Udem, T., & Hänsch, T. W. (2009) · Space sciences series of ISSI · doi:10.1007/978-1-4419-1362-3_20 · Cited by 1
New Developments in Laser Spectroscopy
Demtröder, W. (2015) · Springer eBooks · doi:10.1007/978-3-662-44641-6_9
Krasnogorov, A. J., & Machekhin, Y. P. (2005) · International Conference on Laser and Fiber-Optical Networks Modeling · doi:10.1109/lfnm.2004.1382466
Highly-Accurate Terahertz Frequency Comb toward Establishment of Terahertz Frequency Standard
Nagano, S., Ito, H., Kumagai, M., Kajita, M., & Hanado, Y. (2014) · The Review of Laser Engineering · doi:10.2184/lsj.42.9_711
Optical Clocks for Precision Timing Using Solid State Lasers
Hollberg, L. W., Barber, Z. W., Hoyt, C., Coq, Y. L., Oates, C. W., Fortier, T. M., Stalnaker, J. E., & Diddams, S. A. (2007) · Advanced Solid-State Photonics (TOPS) · doi:10.1364/assp.2007.tua1
Self-citationComparison of Fiber-Based Frequency Comb and Ti:Sapphire-Based Frequency Comb
Lee, W.-K., Yee, D.-S., Suh, H. S., Park, C. Y., Yu, D.-H., Park, S. E., & Kim, E. B. (2007) · Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR) · doi:10.1109/cleopr.2007.4391797
Evaluation of ultra-low expansion spacer in the Fabry-Perot cavity with optical frequency comb
Šmíd, R., Čížek, M., Buchta, Z., Lazar, J., & Číp, O. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2010771
“νopt = fm = f0 + i · fr + fb = mc 4nLcav (7)”
Phase coherence of Ti:sapphire optical frequency combs across hundreds of nanometers
Quraishi, Q. S., Diddams, S. A., & Hollberg, L. W. (2008) · Coherent Optical Technologies and Applications (COTA) · doi:10.1364/cota.2008.cma3
Self-citationUltraprecise and Ultrastable Optical and Microwave Frequency Synthesis with GHz Femtosecond Lasers
Bartels, A. (2009) · Advanced Solid-State Photonics (TOPS) · doi:10.1364/assp.2009.wc1
Self-citationHigh Repetition Rate Optical Frequency Combs – Generation and Applications
Weiner, A. M. (2011) · Nonlinear Optics · doi:10.1364/nlo.2011.nfa2
Generation, characterization, and applications of high repetition rate optical frequency combs
Weiner, A. M. (2012) · IEEE Photonics Conference · doi:10.1109/ipcon.2012.6358706
Supercontinuum generation in microstructure fiber at the advent of femtosecond combs
Cundiff, S. T. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2030615
“Comparisons between combs showed that they did not limit the measurements, but rather it was limited by the intrinsic fluctuations in the quantum transitions being measured and the techniques used to probe it.(31) Recently optical frequency measurements have been limited by the uncertainty in the cesium clock.”
MethodLong-term temperature stabilized measurement of ultra-low expansion Fabry-Perot cavity
Šmíd, R., Čížek, M., Buchta, Z., Lazar, J., & Číp, O. (2012) · European Frequency and Time Forum · doi:10.1109/eftf.2012.6502412
Fiber-based frequency combs with millihertz-level relative linewidths for optical lattice clocks
Inaba, H., Nakajima, Y., Hosaka, K., Iwakuni, K., Yasuda, M., Kohno, T., Akamatsu, D., Minoshima, K., Onae, A., & Hong, F.-L. (2010) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2010.5544507
“The optical chirp of each optical pulse is optimally managed in each EDFA to broaden the spectrum with each HNLF [ 7 ].”
MethodResidual stability of a fiber-based frequency comb
Swann, W. C., Coddington, I. R., Lorini, L., Bergquist, J., Diddams, S. A., & Newbury, N. R. (2007) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2007.4453016
Self-citationLee, W.-K., Yu, D.-H., Park, C. Y., & Mun, J. (2010) · European Frequency and Time Forum · doi:10.1109/eftf.2010.6533720
Spectral Dependence of Phase Noise of Stabilized Optical Frequency Combs
Quraishi, Q. S., Diddams, S. A., & Hollberg, L. W. (2007) · Springer series in chemical physics · doi:10.1007/978-3-540-68781-8_45
Self-citationLong-term measurement of ultra-low expansion Fabry-Perot cavity in stabilized temperature
Šmíd, R., Čížek, M., Buchta, Z., Lazar, J., & Číp, O. (2012) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2012.6243666
Testing the Broadband Phase Coherence of a Mode Locked Laser at Microhertz Relative Linewidth
Martin, M. J., Foreman, S. M., Schibli, T. R., & Ye, J. (2009) · Advanced Solid-State Photonics (TOPS) · doi:10.1364/assp.2009.ma3
Improvement in accuracy of a single40Ca+optical clock towards the 10−15level using a magnetic shield
Matsubara, K., Li, Y., Nagano, S., Ito, H., Kajita, M., Kojima, R., Hanado, Y., Hayasaka, K., & Hosokawa, M. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977880
“In order to minimize the phase noise due to the fiber transfer, we used a cancellation system [ 5 ].”
MethodFemtosecond comb linewidths due to pulse dynamics in mode-locked laser
Cundiff, S. T., Wahlstrand, J. K., Willits, J. T., Schibli, T. R., & Menyuk, C. R. (2007) · IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS) · doi:10.1109/leos.2007.4382609
Determining thickness independently from optical constants using ultrafast spectral interferometry
Huang, F., Federici, J. F., Gary, D. E., Jedju, T. M., & Warren, W. S. (2005) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2005.202038
Optical and microwave frequency stability: some constraints
Hollbeig, L., Diddams, S. A., Bartels, A., McFerran, J. J., Ivanov, E. N., Wilpers, G., & Oates, C. W. (2005) · IEEE/LEOS Summer Topical Meetings · doi:10.1109/leosst.2005.1528025
Self-citationThe Impact of Frequency Comb Stability on Optical Arbitrary Waveform Generation
Huang, C., Jiang, Z. L., Leaird, D. E., & Weiner, A. M. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275437
Fang, Z., & Li, T. (2005) · IEEE/LEOS Summer Topical Meetings · doi:10.1109/leosst.2005.1528009
Calculation of the quantum-limited comb lineshape for a mode-locked Ti:sapphire laser
Willits, J. T., Wahlstrand, J. K., Cundiff, S. T., & Menyuk, C. R. (2008) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2008.4623039
“Combs have been shown to be comparable with 1 s Allen deviation on the order of 10 fractional uncertainty [18]; calculations presented here suggest that this could be improved by an order of magnitude to about 10 with the reduction of technical noise.”
BackgroundVibration immune fiber-laser frequency comb based on a polarization-maintaining figure-eight laser
Giorgetta, F. R., Baumann, E., Nicholson, J. W., Swann, W. C., Coddington, I. R., & Newbury, N. R. (2009) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo.2009.ctuk1
Absolute Optical Frequency Measurements with a Fractional Frequency Uncertainty at 1 ՠ10¿15
Stalnaker, J. E., Diddams, S. A., Kim, K., Hollberg, L. W., Donley, E. A., Heavner, T. P., Jefferts, S. R., Levi, F., Parker, T. E., Bergquist, J., et al. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275430
Self-citationA variable repetition rate frequency comb for infrared frequency metrology
Washburn, B. R., Fox, R. W., Swann, W. C., Newbury, N. R., Nicholson, J. W., Feder, K. S., & Westbrook, P. S. (2005) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2005.202314
Improved measurement of the40Ca+clock transition frequency towards an uncertainty of 10−15level
Matsubara, K., Hayasaka, K., Li, Y., Nagano, S., Ito, H., Kojima, R., Kajita, M., Hanado, Y., Koyama, Y., & Hosokawa, M. (2011) · URSI General Assembly and Scientific Symposium · doi:10.1109/ursigass.2011.6050324
Optical Frequency Measurement with a Mode-Locked Laser: Principle and Recent Development
Sugiyama, K. (2007) · The Review of Laser Engineering · doi:10.2184/lsj.35.228
Pulse Dynamics in Mode-Locked Lasers
Cundiff, S. T., Wahlstrand, J. K., Willits, J. T., Smith, R. P., Schibli, T. R., & Menyuk, C. R. (2007) · doi:10.1364/np.2007.ntha1
Development and Applications of Time and Frequency Standards
Hong, F.-L. (2014) · Journal of the Japan Society for Precision Engineering · doi:10.2493/jjspe.80.634
Femtosecond laser optical frequency synthesizers with uncertainty at the 10−19 level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M. E., Windeler, R. S., Wilpers, G., Oates, C. W., Hollberg, L. W., & Diddams, S. A. (2005) · Springer series in chemical physics · doi:10.1007/3-540-27213-5_255
Self-citationOptical Lattice Clocks for Precision Frequency Metrology
Takamoto, M. (2011) · The Review of Laser Engineering · doi:10.2184/lsj.39.825
The era of coherent optical frequency references
Hollberg, L. W., Oates, C. W., Diddams, S. A., Wilpers, G., Bartels, A., Hoyt, C., & Barber, Z. W. (2004) · Symposium on Optical Fiber Measurements (SOFM) · doi:10.1109/sofm.2004.183462
Self-citationLocking lasers with large FM noise to high Q cavities
Duan, L., & Gibble, K. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1574058
Calibration System based on a Laser Frequency Comb
Sizmann, A., Fischer, M., & Holzwarth, R. (2006)
Lytle, C. R. (2016) · UA Campus Repository (The University of Arizona)
Viewpoint on optical frequency divider with 10–21 precision
Li, Y. (2016) · National Science Review · doi:10.1093/nsr/nww085
Optical Frequency Synthesis Using Fiber-Based Frequency Combs with Uncertainty at 10-19 Level
Inaba, H., Nakajima, Y., Hosaka, K., Onae, A., & Hong, F.-L. (2011) · The Review of Laser Engineering · doi:10.2184/lsj.39.819
High contrast beating 6 lines to a single branch amplifier-free GHz Yb:fiber laser frequency comb
Ma, Y., Meng, F., Wang, Y., Wang, A., & Zhang, Z. (2019) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2019.sf1l.6
Spectral purity transfer between optical wavelengths at the 10−18 level
Nicolodi, D., Argence, B., Zhang, W., Targat, R. L., Santarelli, G., & Coq, Y. L. (2014) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2014.6898260
An Optical Frequency Standard with Single 40Ca+ Ions
Matsubara, K., Li, Y., Nagano, S., Ito, H., HOSOKAWA, K., & NAGANO, M. (2010) · The Review of Laser Engineering · doi:10.2184/lsj.38.517
Yin, J., Dong, T., Su, Y., Shi, H., Zhou, Y., & Xu, K. (2019) · Asia Communications and Photonics Conference
Absolute Distance Measurements based on the Optical Comb of a Femtosecond Pulse Laser
Kim, S., Kim, Y., Hyun, S., & Kim, Y. (2007)
Applications of WGM Microcavities in Physics
Vollmer, F., & Yu, D. (2020) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-030-60235-2_4
A broadband passive cavity for analyzing and filtering the noise of a femtosecond laser
Xiang, X., Shao-Feng, W., Fei-Yan, H., Run-Ai, Q., Yi-Wei, Z., Wang, M., Cong-Hua, Z., Xu, G., Dong, R., Liu, T., et al. (2016) · Acta Physica Sinica · doi:10.7498/aps.65.134203
Muntean, K. I. (2019) · Visnyk of V N Karazin Kharkiv National University series “Radio Physics and Electronics” · doi:10.26565/2311-0872-2019-31-08
Spectral dependence of phase noise of stabilized optical frequency combs
Quraishi, Q. S., Diddams, S. A., & Hollberg, L. W. (2006) · International Conference on Ultrafast Phenomena · doi:10.1364/up.2006.mh16
Self-citationOctave-spanning comb generation and optical frequency measurement using mode-locked fiber lasers
Inaba, H., Nakajima, Y., Minoshima, K., Hong, F.-L., Onae, A., Nakazawa, M., & Matsumoto, H. (2008) · The Review of Laser Engineering · doi:10.2184/lsj.36.26
Ultrahigh-Q packaged silica microrod cavity for microcomb generation
Chen, W., Yao, L., Li, C., Chen, H.-J., Yang, D., & Xiao, Y. (2022) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2022.sth2f.4
Applications of WGM Microcavities in Physics
Vollmer, F., & Yu, D. (2022) · Springer eBooks · doi:10.1007/978-3-031-06858-4_4
Metadata
- Authors
- Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ma, Long-Sheng
- Bi, Zhiyi
- Bartels, Albrecht
- Diddams, Scott A.
- Venue
- Science
- Published
- 2004-03-19
- Volume
- 303
- Issue
- 5665
- Pages
- 1843-1845
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2070006052
- Cited by
- 319
- References
- 23
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 14 · 2019: 13 · 2018: 15 · 2017: 12 · 2016: 14 · 2015: 16 · 2014: 16 · 2013: 8 · 2012: 16
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
- nbn-resolving.de
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- KOPS (University of Konstanz) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Keywords
- optical frequency synthesis, femtosecond laser, optical frequency standard, frequency uncertainty, terahertz bandwidth, frequency regulation, reproducibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.