Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A femtosecond laser–based optical frequency synthesizer is referenced to an optical standard, and we use it to demonstrate the generation and control of the frequency of electromagnetic fields over 100 terahertz of bandwidth with fractional uncertainties approaching 1 part in 10 19 . The reproducibility of this performance is verified by comparison of different types of femtosecond laser–based frequency synthesizers from three laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They compared the different”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is due to the fact that the time and frequency science develop very quickly, and clocks or time-keeping systems and portable clocks with the stability better than 1 × 10 -18 might be available in the near future [22,27].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Allan, D. W. (1987) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/t-uffc.1987.26997 · Cited by 853
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Absolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Accurate measurement of large optical frequency differences with a mode-locked laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Optics Letters · doi:10.1364/ol.24.000881 · Cited by 418
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Research works printed but not linked: 4
- 1. P. Gill, Ed., Proceedings of the 6th Symposium on Frequency Standards and Metrology (World Scientific, Singapore, 2002).
- 7. S. G. Karshenboim, Can. J. Phys. 78, 639 (2000). · doi:10.1139/p00-045 · Paper page
- 24. A. Sen Gupta, D. Popovic, F. L. Walls, in Proceedings of the 1999 joint Meeting of the European Frequency and Time Forum (EFTF) and the EEE International Frequency Control Symposium (FCS), Besançon, France, 13 to 16 April 1999 (IEEE, Piscataway, NJ, 1999), pp. 615–619.
- 25. A. Bartels, S. A. Diddams, T. M. Ramond, L. Hollberg, Opt. Lett. 28, 663 (2002).
Cited by
Items 101–200 of 325
Kashiwagi, K., Nakajima, Y., Wada, M., Okubo, S., & Inaba, H. (2018) · Optics Express · doi:10.1364/oe.26.008831 · Cited by 27
Determination of the geopotential and orthometric height based on frequency shift equation
Shen, W., Ning, J., Liu, J., Li, J., & Chao, D. (2011) · Natural Science · doi:10.4236/ns.2011.35052 · Cited by 26
Electronic Structure and Spectra of the MgLi+ Ionic Molecule
ElOualhazi, R., & Berriche, H. (2015) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.5b10209 · Cited by 26
Recent progresses of ultracold two-electron atoms
He, C., Hajiyev, E., Ren, Z., Song, B., & Jo, G.-B. (2019) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab153e · Cited by 31
The Strontium Optical Lattice Clock: Optical Spectroscopy with Sub-Hertz Accuracy
Ludlow, A. D. (2008) · Bulletin of the American Physical Society · Cited by 50
Optical frequency synthesis and measurement using fibre-based femtosecond lasers
Grosche, G., Lipphardt, B., & Schnatz, H. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00065-7 · Cited by 26
Testing the Stability of the Fine Structure Constant in the Laboratory
Kolachevsky, N., Matveev, A., Alnis, J., Parthey, C. G., Steinmetz, T., Wilken, T., Holzwarth, R., Udem, T., & Hänsch, T. W. (2009) · Space Science Reviews · doi:10.1007/s11214-009-9564-z · Cited by 28
Optical frequency synthesizer referenced to an ytterbium optical clock
Yao, Y., Li, B., Yang, G. H., Chen, X., Hao, Y., Yu, H., Jiang, Y., & Ma, L.-S. (2021) · Photonics Research · doi:10.1364/prj.409534 · Cited by 26
Self-citationOptical frequency synthesis and measurement using fibre-based femtosecond lasers
Grosche, G., Lipphardt, B., & Schnatz, H. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2008-00178-y · Cited by 25
Stable Similariton Generation in an All-Fiber Hybrid Mode-Locked Ring Laser for Frequency Metrology
Lazarev, V. A., Krylov, A. A., Dvoretskiy, D. A., Sazonkin, S. G., Pnev, A. B., Leonov, S. O., Shelestov, D. A., Tarabrin, M. K., Karasik, V. E., Kireev, A. N., et al. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2542368 · Cited by 24
“frequency comb, in the last decade, they became one of the most important instruments in frequency metrology [5], [6].”
BackgroundFundamental constants and tests of theory in Rydberg states of one-electron ions
Jentschura, U. D., Mohr, P. J., & Tan, J. N. (2010) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/43/7/074002 · Cited by 29
“The advent of optical frequency combs (Hänsch 2006) has opened the possibility of making precise measurements of optical transitions between Rydberg states in one-electron ions, with potential for higher precision (Ma et al 2004) and broader range of applications (Marian et al 2004).”
BackgroundGeneration of ultralow power phononic combs
Goryachev, M., Galliou, S., & Tobar, M. E. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.023035 · Cited by 23
Shen, Z., Shen, W., Zhao, P., Liu, T., Zhang, S., & Chao, D. (2019) · Journal of Earth Science · doi:10.1007/s12583-018-0834-0 · Cited by 24
Integrated electro-optical phase-locked loop for high resolution optical synthesis
Ashtiani, F., & Aflatouni, F. (2017) · Optics Express · doi:10.1364/oe.25.016171 · Cited by 21
Visible-Spanning Flat Supercontinuum for Astronomical Applications
Ravi, A., Beck, M., Phillips, D. F., Bartels, A., Sasselov, D. D., Szentgyorgyi, A. H., & Walsworth, R. L. (2018) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2872423 · Cited by 21
“[21], and is referenced to a GPS-disciplined Rb frequency standard, yielding a fractional stability of better than 10−12 [22].”
BackgroundSelf-citationNagano, S., Ito, H., Li, Y., Matsubara, K., & Hosokawa, M. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.042301 · Cited by 21
A low noise optical frequency synthesizer at 700–990 nm
Yao, Y., Jiang, Y., Wu, L., Yu, H., Bi, Z., & Ma, L.-S. (2016) · Applied Physics Letters · doi:10.1063/1.4963690 · Cited by 21
Self-citationXu, B., Fan, X., Wang, S., & He, Z. (2021) · Optics Letters · doi:10.1364/ol.420377 · Cited by 20
Zhang, P., Zhang, Y., Li, M., Rao, B., Yan, L., Chen, F., Zhang, X.-F., Chen, Q., Jiang, H., & Zhang, S. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac40f6 · Cited by 19
Improved supercontinuum generation through UV processing of highly nonlinear fibers
Westbrook, P. S., Nicholson, J. W., Feder, K. S., & Yablon, A. D. (2005) · Journal of Lightwave Technology · doi:10.1109/jlt.2004.840361 · Cited by 18
“precision frequency ruler that has enabled vast improvements in absolute frequency measurements [ 9 ].”
BackgroundNovel Techniques for Remote Time and Frequency Comparisons
Piester, D., & Schnatz, H. (2009) · Cited by 20
Walk-off controlled self-starting frequency combs in χ(2) optical microresonators
Smirnov, S. V., Sturman, B. I., Podivilov, E., & Breunig, I. (2020) · Optics Express · doi:10.1364/oe.395360 · Cited by 19
Extended ultrahigh-Q-cavity diode laser
Xie, Z., Liang, W. G., Savchenkov, A. A., Lim, J., Burkhart, J., McDonald, M., Zelevinsky, T., Ilchenko, V. S., Matsko, A. B., Maleki, L., et al. (2015) · Optics Letters · doi:10.1364/ol.40.002596 · Cited by 18
Jiang, Y., Bi, Z., Robertsson, L., & Ma, L.-S. (2005) · Metrologia · doi:10.1088/0026-1394/42/4/016 · Cited by 17
Self-citationPhononic Frequency Combs in Stand-Alone Piezoelectric Resonators
Park, M., & Ansari, A. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597504 · Cited by 17
“The spectrum of a frequency comb is traditionally generated by using a mode-locked laser, which creates a broad bandwidth, spanning over more than a full octave [3].”
BackgroundHall, J. L. (2006) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0176.200612i.1353 · Cited by 18
Implementation and characterization of a stable optical frequency distribution system
Bernhardt, B., Hänsch, T. W., & Holzwarth, R. (2009) · Optics Express · doi:10.1364/oe.17.016849 · Cited by 17
High power optical frequency comb with 10−19 frequency instability
Shao, X., Han, H., Wang, H., Ma, J., Hu, Y., Li, C., Teng, H., Chang, G., Wang, B., & Wei, Z. (2023) · Optics Express · doi:10.1364/oe.499383 · Cited by 17
A new bound on excess frequency noise in second harmonic generation in PPKTP at the 10^−19 level
Yeaton-Massey, D., & Adhikari, R. X. (2012) · Optics Express · doi:10.1364/oe.20.021019 · Cited by 17
Tunable optical frequency comb from a compact and robust Er:fiber laser
Zhu, Z., Liu, Y., Luo, D., Gu, C., Zhou, L., Xie, G., Deng, Z., & Li, W. (2020) · High Power Laser Science and Engineering · doi:10.1017/hpl.2020.17 · Cited by 16
Modified time-delay interferometry with an optical frequency comb
Tan, Y.-J., Xu, M., Wang, P.-P., Wu, H., & Shao, C.-G. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.106.044010 · Cited by 16
Limits to time variation of fundamental constants from comparisons of atomic frequency standards
Lea, S. N. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00808-6 · Cited by 17
Low-noise optical injection locking of a resonant tunneling diode to a stable optical frequency comb
Ramond, T. M., Hollberg, L. W., Juodawlkis, P., & Calawa, S. D. (2007) · Applied Physics Letters · doi:10.1063/1.2734368 · Cited by 16
Self-citationCEO stabilized frequency comb from a 1-μm Kerr-lens mode-locked bulk Yb:CYA laser
Yu, Z., Han, H., Xie, Y., Peng, Y., Xu, X., & Wei, Z. (2016) · Optics Express · doi:10.1364/oe.24.003103 · Cited by 16
Characterization of carrier-envelope phase-sensitive photocurrent injection in a semiconductor
Roos, P. A., Li, X., Pipis, J. A., Fortier, T. M., Cundiff, S. T., Bhat, R. D. R., & Sipe, J. E. (2005) · Journal of the Optical Society of America B · doi:10.1364/josab.22.000362 · Cited by 16
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15
Stabilization of the 397nm and 866nm external cavity diode lasers for cooling a single calcium ion
Guan, H., Guo, B., Huang, G., Shu, H., Huang, X.-R., & Gao, K. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.02.018 · Cited by 15
International Comparisons of Femtosecond Laser Frequency Combs
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M. E., Windeler, R. S., Wilpers, G., Oates, C. W., Hollberg, L. W., & Diddams, S. A. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2005.843580 · Cited by 15
“the beat frequency is equal to and independent of the reference laser frequency [ 20 ].”
BackgroundMethodSelf-citationCalibrating Strain Measurements: A Comparative Study of DAS, Strainmeter, and Seismic Data
Chien, C., Gerstoft, P., Hatfield, W., Hollberg, L. W., Lipovsky, B. P., Manos, J., Mellors, R. J., Winebrenner, D. P., & Zumberge, M. A. (2025) · Earth and Space Science · doi:10.1029/2024ea003940 · Cited by 14
“This temperature record was processed using the filter design described in panel (a). and GPS using a femtosecond optical frequency comb (Ma et al., 2004).”
Self-citationSubmillimeter constraints for non-Newtonian gravity from spectroscopy
Lemos, A. S. (2021) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/135/11001 · Cited by 14
Hдnsh, T. W. (2006) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0176.200612j.1368 · Cited by 15
Optical Atomic Clocks for Space
Gill, P., Margolis, H. S., Curtis, E. A., Klein, H. A., Lea, S. N., Webster, S. A., & Whibberley, P. B. (2008) · Cited by 23
A 729nm laser with ultra-narrow linewidth for probing 4S1/2–3D5/2 clock transition of 40Ca+
Guan, H., Liu, Q., Huang, Y., Guo, B., Qu, W., Cao, J. Z., Huang, G., Huang, X.-R., & Gao, K. (2010) · Optics Communications · doi:10.1016/j.optcom.2010.08.063 · Cited by 14
Einstein Lecture – Passion for precision
Hänsch, T. W. (2006) · Annalen der Physik · doi:10.1002/andp.200610215 · Cited by 17
Cavity-Enhanced Direct Frequency Comb Spectroscopy
Masłowski, P., Cossel, K. C., Foltynowicz, A., & Ye, J. (2013) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-3-642-40003-2_8 · Cited by 17
Simultaneous laser cooling of multiple atomic species using an optical frequency comb
Aumiler, D., & Ban, T. (2012) · Physical Review A · doi:10.1103/physreva.85.063412 · Cited by 13
Noise performance of a feed-forward scheme for carrier-envelope phase stabilization
Koke, S., Anderson, A., Frei, H., Assion, A., & Steinmeyer, G. (2011) · Applied Physics B · doi:10.1007/s00340-011-4654-5 · Cited by 13
Quantum precision measurement based on squeezed light
Heng-Xin, S., Kui, L., Zhang, J., & Jiang-Rui, G. (2015) · Acta Physica Sinica · doi:10.7498/aps.64.234210 · Cited by 13
The Brazilian time and frequency atomic standards program
Ahmed, M., Magalhães, D. V., Bebeachibuli, A., Müller, S., Alves, R. F., Ortega, T. A., Weiner, J., & Bagnato, V. S. (2008) · Anais da Academia Brasileira de Ciências · doi:10.1590/s0001-37652008000200002 · Cited by 17
“Cold atoms and cold ions are certainly the most promising systems for the development of a new atomic standard (Bize et al. 2005, Ma et al. 2004, Udem et al. 2002).”
BackgroundMeasurement of the 27 Al + and 87 Sr absolute optical frequencies
Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., Diddams, S. A., Fasano, R., Hassan, Y. S., Hume, D. B., et al. (2020) · Metrologia · doi:10.1088/1681-7575/abd040 · Cited by 14
“This coherent synthesis permits simultaneous frequency comparison of multiple atomic clocks with an additive fractional instability of 1 × 10 − 17 ( τ/ 1 s) − 1 / 2 [7], and additive uncertainty below 1 part in 10 19 [15–19].”
Self-citationOptical frequency divider: Capable of measuring optical frequency ratio in 22 digits
Shi, H., Jiang, Y., Yao, Y., Li, B., Wang, C., Yu, H., & Ma, L. (2023) · APL Photonics · doi:10.1063/5.0165602 · Cited by 14
Self-citationMode-locked picosecond pulse generation from an octave-spanning supercontinuum
Kielpinski, D., Pullen, M. G., Canning, J., Stevenson, M., Westbrook, P. S., & Feder, K. S. (2009) · Optics Express · doi:10.1364/oe.17.020833 · Cited by 12
Tillman, K. A., Thapa, R., Knabe, K., Wu, S., Lim, J., Washburn, B. R., & Corwin, K. L. (2009) · Applied Optics · doi:10.1364/ao.48.006980 · Cited by 12
Femtosecond Lasers for Optical Clocks and Low Noise Frequency Synthesis
Diddams, S. A., Ye, J., & Hollberg, L. W. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-23791-7_9 · Cited by 15
Self-citationCharacterization of AM-to-PM Conversion in Silicon p-i-n Photodiodes
Kang, L., & Kolner, B. H. (2019) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2019.2914607 · Cited by 11
Tarabrin, M. K., Lazarev, V. A., Karasik, V. E., Kireev, A. N., Korostelin, Y. V., Shelkovnikov, A. S., Tuyrikov, D. A., Kozlovsky, V. I., Podmar'kov, Y. P., Frolov, M. P., et al. (2016) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2016.03.002 · Cited by 11
Jitter analysis of timing-distribution and remote-laser synchronization systems
Şafak, K., Xin, M., Zhang, Q., Chia, S., Mücke, O. D., & Käertner, F. X. (2016) · Optics Express · doi:10.1364/oe.24.021752 · Cited by 11
Mode-locked picosecond pulse generation from an octave-spanning supercontinuum
Kielpinski, D., Pullen, M., Canning, J., Stevenson, M., Westbrook, P. S., & Feder, K. S. (2009) · Griffith Research Online · Cited by 11
Frequency stabilisation of a fibre-laser comb using a novel microstructured fibre
Locke, C. R., Ivanov, E. N., Light, P. S., Benabid, F., & Luiten, A. N. (2009) · Optics Express · doi:10.1364/oe.17.005897 · Cited by 10
Li, J., Shen, S.-T., Qu, Y., Zhang, D., & Wu, Y. (2018) · Physical Review A · doi:10.1103/physreva.98.023848 · Cited by 10
Femtosecond Frequency Combs for Optical Clocks and Timing Transfer
Foreman, S. M. (2007) · Cited by 11
Experimental Improvement of Signal of a Single Laser-Cooled Trapped 40 Ca + Ion
Hua-Lin, S., Guo, B., Hua, G., Qu, L., Xue-Ren, H., & Gao, K. (2007) · Chinese Physics Letters · doi:10.1088/0256-307x/24/5/025 · Cited by 10
Determining thickness independently from optical constants by use of ultrafast light
Huang, F., Federici, J. F., & Gary, D. E. (2004) · Optics Letters · doi:10.1364/ol.29.002435 · Cited by 12
Review on the recent progress of laser frontiers in China
Lin, Z., Chen, W., Lou, Q., Fan, W., Xiang, S., & Xue, H. (2013) · Science China Technological Sciences · doi:10.1007/s11431-013-5228-z · Cited by 9
Frequency combs applications and optical frequency standards
Udem, T., & Riehle, F. (2007) · Rivista Del Nuovo Cimento · doi:10.1393/ncr/i2007-10027-5 · Cited by 24
Nishiyama, A., Matsuba, A., & Misono, M. (2014) · Optics Letters · doi:10.1364/ol.39.004923 · Cited by 8
Frequency comb solutions for driven χ(2) optical microresonators
Podivilov, E. V., Sturman, B. I., & Breunig, I. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.402007 · Cited by 8
Coherent Comb Generation With Continuous Sweep of Repetition Rate Over One-Octave
Xie, W., Zhou, Q., Zhang, C., Xia, Z., Shi, H., Dong, Y., Yi, L., & Hu, W. (2013) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2013.2287215 · Cited by 8
“Broadband flat-top OFC with arbitrary control of the repetition rate (comb-spacing) working at tens-of-GHz-class is highly beneficial and extensively demanded for applications such as optical arbitrary waveform generation [1], [2], broadband tunable microwave photonic filters [3], atomic and molecular spectroscopy [4]…”
BackgroundOrthometric height determination based upon optical clocks and fiber frequency transfer technique
Shen, W.-B. (2013) · Saudi International Electronics, Communications and Photonics Conference · doi:10.1109/siecpc.2013.6550987 · Cited by 8
Strontium optical lattice clock
Yi-Ge, L., & Fang, Z. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20181097 · Cited by 8
Transfer of laser frequency from 729 nm to 1.5 µm with precision at the level of 10−20
Fang, P., Sun, H., Wang, Y., Xu, Y., & Chen, Q. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081403 · Cited by 8
Rydberg states of hydrogenlike ions in a braneworld model
Dahia, F., Maciel, E., & Lemos, A. S. (2018) · The European Physical Journal C · doi:10.1140/epjc/s10052-018-6007-6 · Cited by 8
High-resolution spectroscopy of the88Sr+single ion optical frequency standard
Dubé, P., Madej, A. A., Bernard, J. E., & Shiner, A. D. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.734689 · Cited by 8
Distribution of an Ultrastable Frequency Reference Using Optical Frequency Combs
Holman, K. W. (2005) · Cited by 10
Schibli, T. R. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.240 · Cited by 7
Frequency-comb-induced radiative force on cold rubidium atoms
Kregar, G., Šantić, N., Aumiler, D., Buljan, H., & Ban, T. (2014) · Physical Review A · doi:10.1103/physreva.89.053421 · Cited by 7
Yao, Y., Jiang, Y., & Ma, L.-S. (2019) · National Science Review · doi:10.1093/nsr/nwz209 · Cited by 7
Self-citationSamoudi, B., Pérez, M. M., Ferreira-Barragáns, S., & Prieto, E. (2012) · International Journal of Metrology and Quality Engineering · doi:10.1051/ijmqe/2012012 · Cited by 7
Optoelectronic Control of the Phase and Frequency of Semiconductor Lasers
Satyan, N. (2011) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/24dm-vw62 · Cited by 7
Yi, L., Qi, X., Chen, W., Chen, J., Zhou, X., & Chen, X. (2008) · Optics Communications · doi:10.1016/j.optcom.2008.04.013 · Cited by 8
Hadjiloucas, S., Walker, G. C., Bowen, J. W., & Karatzas, L. S. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/178/1/012036 · Cited by 6
“Improving upon this figure will have profound implications in optical time metrology; the goal for the next generation of optical frequency standards is a stability at the level of 10 per year [7].”
BackgroundDirect comparison of optical frequency combs using a comb-injection-lock technique
Kim, E. B., Lee, W. K., Park, C. Y., Yu, D.-H., Lee, S. K., & Park, S. E. (2008) · Optics Express · doi:10.1364/oe.16.010721 · Cited by 6
Yin, J., Dong, T., Su, Y., Zhou, Y., & Xu, K. (2018) · Asia Communications and Photonics Conference · doi:10.1109/acp.2018.8596054 · Cited by 5
“Furthermore, the optical frequency comb (OFC) acts like a ruler from optical frequency to radio frequency with fractional uncertainties of 10−(19) or lower [6,7].”
BackgroundObservation of subnatural-linewidth spectra in cold Li6 atoms
Li, R., Wu, Y., Rui, Y., & Wu, H. (2021) · Physical Review A · doi:10.1103/physreva.103.032823 · Cited by 5
Magic wavelengths of the optical clock transition at 877 nm of barium
Yu, G.-H., Xu, Q., Zhou, C., Liang, L., Li, L., & Chai, R.-P. (2014) · Modern Physics Letters B · doi:10.1142/s0217984914501838 · Cited by 6
Direct phase-locking of a Ti:Sapphire optical frequency comb to a remote optical frequency standard
Chae, E., Nakashima, K., Ikeda, T., Sugiyama, K., & Yoshioka, K. (2019) · Optics Express · doi:10.1364/oe.27.015649 · Cited by 5
Modal Analysis Investigation of Mechanical Kerr Frequency Combs
Houri, S., Hatanaka, D., Blanter, Y. M., & Yamaguchi, H. (2019) · Springer proceedings in physics · doi:10.1007/978-981-13-9463-8_7 · Cited by 7
“The highly periodic signal output and equidistant spectral components have made optical frequency combs an invaluable tool for timing and spectroscopy applications (Eckstein et al. 1978, Udem et al. 1999, Diddams 2000, Ma et al. 2004).”
Frequency Metrology with Optical Lattice Clocks
Hong, F.-L., & Katori, H. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.080001 · Cited by 6
High repetition rate passively mode-locked erbium-doped fiber laser
Li, J., Dai, Y., & Zhang, Z. (2008) · Chinese Science Bulletin · doi:10.1007/s11434-008-0150-7 · Cited by 5
Šmíd, R., Čížek, M., Buchta, Z., Lazar, J., & Číp, O. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977887 · Cited by 4
Precision locking CW laser to ultrastable optical frequency comb by feed-forward method
Shao, X., Han, H., Su, Y., Wang, H., Zhang, Z., Fang, S. B., Chang, G., & Wei, Z. (2019) · AIP Advances · doi:10.1063/1.5121860 · Cited by 4
Characterization of an optical frequency comb using modified direct frequency comb spectroscopy
Aumiler, D., Ban, T., Vujičić, N., Vdović, S., Skenderović, H., & Pichler, G. (2009) · Applied Physics B · doi:10.1007/s00340-009-3630-9 · Cited by 4
Hall, J. L. (2017) · Journal of the Optical Society of America B · doi:10.1364/josab.34.000338 · Cited by 4
Bilicki, S. (2017) · theses.fr (ABES) · doi:10.70675/4b3e81f4z8872z4d16z8156z517133a256ac · Cited by 9
“In this way, a direct optical-optical comparison is possible by monitoring the beat notes between given comb lines and clock lasers, with a stability and accuracy limited by clocks themselves only [173,174].”
BackgroundResearch progress on clock noise suppression technique for space-borne gravitational wave detection
Xu, M., Tan, Y.-J., & Shao, C.-G. (2024) · Zhongguo kexue. Wulixue Lixue Tianwenxue · doi:10.1360/sspma-2024-0365 · Cited by 3
Feng, C., Luo, X., Duan, J., Lyu, H., Yu, L.-Y., Qi, X. B., Yang, Q.-F., & Wang, Y. (2025) · Review of Scientific Instruments · doi:10.1063/5.0291881 · Cited by 3
Laser frequency stability transfer using a fiber-based interferometer
Wang, Z. B., Zhang, J., Wang, S., Miao, K., & Wang, L. (2014) · Applied Optics · doi:10.1364/ao.53.003283 · Cited by 3
Wei, Z., Hai-Nian, H., Hao, T., & Zhi-Yi, W. (2009) · Chinese Physics B · doi:10.1088/1674-1056/18/3/044 · Cited by 3
Feng, G., Hong, C., Wang, X., Xiao, T., & Zhang, S. (2011) · Acta Physica Sinica · doi:10.7498/aps.60.050601 · Cited by 3
Optical Phase Locked Loop and Frequency Transfer
Fang, Z., Cai, H., Chen, G., & Qu, R. (2017) · Optical and fiber communications reports · doi:10.1007/978-981-10-5257-6_8 · Cited by 4
Metadata
- Authors
- Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ma, Long-Sheng
- Bi, Zhiyi
- Bartels, Albrecht
- Diddams, Scott A.
- Venue
- Science
- Published
- 2004-03-19
- Volume
- 303
- Issue
- 5665
- Pages
- 1843-1845
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2070006052
- Cited by
- 319
- References
- 23
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 14 · 2019: 13 · 2018: 15 · 2017: 12 · 2016: 14 · 2015: 16 · 2014: 16 · 2013: 8 · 2012: 16
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
- nbn-resolving.de
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- KOPS (University of Konstanz) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Keywords
- optical frequency synthesis, femtosecond laser, optical frequency standard, frequency uncertainty, terahertz bandwidth, frequency regulation, reproducibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.