The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Open accessAbstract
A femtosecond laser–based optical frequency synthesizer is referenced to an optical standard, and we use it to demonstrate the generation and control of the frequency of electromagnetic fields over 100 terahertz of bandwidth with fractional uncertainties approaching 1 part in 10 19 . The reproducibility of this performance is verified by comparison of different types of femtosecond laser–based frequency synthesizers from three laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“They compared the different”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This is due to the fact that the time and frequency science develop very quickly, and clocks or time-keeping systems and portable clocks with the stability better than 1 × 10 -18 might be available in the near future [22,27].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [27]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Allan, D. W. (1987) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/t-uffc.1987.26997 · Cited by 853
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Absolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Accurate measurement of large optical frequency differences with a mode-locked laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Optics Letters · doi:10.1364/ol.24.000881 · Cited by 418
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
High-Resolution Two-Photon Spectroscopy with Picosecond Light Pulses
Eckstein, J. N., Ferguson, A. I., & Hänsch, T. W. (1978) · Physical Review Letters · doi:10.1103/physrevlett.40.847 · Cited by 298
Atomic Clocks and Variations of the Fine Structure Constant
Prestage, J. D., Tjoelker, R. L., & Maleki, L. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3511 · Cited by 298
Phase-Coherent Optical Pulse Synthesis from Separate Femtosecond Lasers
Shelton, R. K., Ma, L.-S., Kapteyn, H. C., Murnane, M. M., Hall, J. L., & Ye, J. (2001) · Science · doi:10.1126/science.1061754 · Cited by 250
Self-citationTesting the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock
Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150802 · Cited by 249
Self-citationYe, J., Ma, L. S., & Hall, J. L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.270801 · Cited by 206
Self-citationUltraprecise Measurement of Optical Frequency Ratios
Stenger, J., Schnatz, H., Tamm, C., & Telle, H. R. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.073601 · Cited by 157
Some possibilities for laboratory searches for variations of fundamental constants
Karshenboim, S. G. (2000) · Canadian Journal of Physics · doi:10.1139/p00-045 · Cited by 135
Zimmermann, M., Gohle, C., Holzwarth, R., Udem, T., & Hänsch, T. W. (2004) · Optics Letters · doi:10.1364/ol.29.000310 · Cited by 132
Oates, C. W., Curtis, E. A., & Hollberg, L. W. (2000) · Optics Letters · doi:10.1364/ol.25.001603 · Cited by 89
Self-citationFemtosecond-laser-based optical clockwork with instability ≤63 × 10^–16 in 1 s
Diddams, S. A., Hollberg, L. W., Ma, L.-S., & Robertsson, L. (2002) · Optics Letters · doi:10.1364/ol.27.000058 · Cited by 85
Self-citationEvaluating the Measurement Uncertainty
Lira, I. H. (2002) · Institute of Physics eBooks · doi:10.1887/0750308400 · Cited by 85
Bartels, A., Diddams, S. A., Ramond, T. M., & Hollberg, L. W. (2003) · Optics Letters · doi:10.1364/ol.28.000663 · Cited by 74
Self-citationEvaluating the Measurement Uncertainty
Lira, I. H. (2002) · CRC Press eBooks · doi:10.1201/9780367801564 · Cited by 55
Research works printed but not linked: 3
- P. Gill Ed. Proceedings of the 6th Symposium on Frequency Standards and Metrology (World Scientific Singapore 2002).
- A. Sen Gupta, D. Popovic, F. L. Walls, in Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum (EFTF) and the IEEE International Frequency Control Symposium (FCS), Besançon, France, 13 to 16 April 1999 (IEEE, Piscataway, NJ, 1999), pp. 615–619.
- A. Bartels, S. A. Diddams, T. M. Ramond, L. Hollberg, Opt. Lett.28, 663 (2002).
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationNobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
“In 2004, researchers in Boulder compared four different frequency combs from different laboratories, finding agreement between neighboring comb lines at an uncertainty level of 10−19 Ma et al., 2004 .”
BackgroundUltrafast optical pulse shaping: A tutorial review
Weiner, A. M. (2011) · Optics Communications · doi:10.1016/j.optcom.2011.03.084 · Cited by 742
“, [120-122], an accomplishment for which the Nobel Prize in Physics was awarded in 2005.”
BackgroundThe evolving optical frequency comb [Invited]
Diddams, S. A. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.000b51 · Cited by 615
Self-citation
Metadata
- Authors
- Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ma, Long-Sheng
- Bi, Zhiyi
- Bartels, Albrecht
- Diddams, Scott A.
- Venue
- Science
- Published
- 2004-03-19
- Volume
- 303
- Issue
- 5665
- Pages
- 1843-1845
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2070006052
- Cited by
- 319
- References
- 23
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 14 · 2019: 13 · 2018: 15 · 2017: 12 · 2016: 14 · 2015: 16 · 2014: 16 · 2013: 8 · 2012: 16
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
- nbn-resolving.de
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- KOPS (University of Konstanz) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Keywords
- optical frequency synthesis, femtosecond laser, optical frequency standard, frequency uncertainty, terahertz bandwidth, frequency regulation, reproducibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.