The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Abstract
The frequency of the 5s 2 S 1/2 –4d 2 D 5/2 electric quadrupole clock transition in a single, trapped, laser-cooled 88 Sr + ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary cesium standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Accurate measurement of large optical frequency differences with a mode-locked laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Optics Letters · doi:10.1364/ol.24.000881 · Cited by 418
Monoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Limit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
Sub-dekahertz Ultraviolet Spectroscopy of199Hg+
Rafac, R. J., Young, B. C., Beall, J. A., Itano, W. M., Wineland, D. J., & Bergquist, J. C. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2462 · Cited by 266
Absolute Frequency Measurements of theHg+and Ca Optical Clock Transitions with a Femtosecond Laser
Udem, T., Diddams, S. A., Vogel, K. R., Oates, C. W., Curtis, E. A., Lee, W. D., Itano, W. M., Drullinger, R. E., Bergquist, J. C., & Hollberg, L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4996 · Cited by 260
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationRemote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Ultralow noise miniature external cavity semiconductor laser
Liang, W., Ilchenko, V. S., Eliyahu, D., Savchenkov, A. A., Matsko, A. B., Seidel, D., & Maleki, L. (2015) · Nature Communications · doi:10.1038/ncomms8371 · Cited by 398
‘Designer atoms’ for quantum metrology
Roos, C. F., Chwalla, M., Kim, K., Riebe, M., & Blatt, R. (2006) · Nature · doi:10.1038/nature05101 · Cited by 343
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114
Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82
Efficient Atomic Clocks Operated with Several Atomic Ensembles
Borregaard, J., & Sørensen, A. S. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.090802 · Cited by 67
Absolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
Dubé, P., Bernard, J. E., & Gertsvolf, M. (2017) · Metrologia · doi:10.1088/1681-7575/aa5e60 · Cited by 28
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Toward a Transportable Ca+ Optical Clock with a Systematic Uncertainty of 4.8 × 10 −18
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23
Metadata
- Authors
- Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P.
- Venue
- Science
- Published
- 2004-11-19
- Volume
- 306
- Issue
- 5700
- Pages
- 1355-1358
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2084144772
- Cited by
- 301
- References
- 20
- FWCI
- 16.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.