The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Mass Spectrometry: Bottom-Up or Top-Down?
Abstract
Targeted Top-Down Mass Spectrometry for the Characterization and Tissue-Specific Functional Discovery of Crustacean Hyperglycemic Hormones (CHH) and CHH Precursor-Related Peptides in Response to Low pH Stress,
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein Cations
Zubarev, R. A., Horn, D. M., Fridriksson, E. K., Kelleher, N. L., Kruger, N. A., Lewis, M. A., Carpenter, B. K., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac990811p · Cited by 986
Weighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Self-citationProtein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Subunit architecture of multimeric complexes isolated directly from cells
Hernández, H., Dziembowski, A., Taverner, T., Séraphin, B., & Robinson, C. V. (2006) · EMBO reports · doi:10.1038/sj.embor.7400702 · Cited by 178
POM152 is an integral protein of the pore membrane domain of the yeast nuclear envelope.
Wozniak, R. W., Blobel, G., & Rout, M. P. (1994) · The Journal of Cell Biology · doi:10.1083/jcb.125.1.31 · Cited by 136
Nanoflow LC/IMS-MS and LC/IMS-CID/MS of protein mixtures
Robinson, R. A. S., Koeniger, S. L., Valentine, S. J., Moon, M. H., & Clemmer, D. E. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.06.014 · Cited by 46
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Mass spectrometry-based proteomics has traditionally been carried out in a Bottom Up approach [3,4].”
MethodBest practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
Metadata
- Authors
- Chait, B. T.
- Venue
- Science
- Published
- 2006-10-06
- Volume
- 314
- Issue
- 5796
- Pages
- 65-66
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1530371703
- Cited by
- 441
- References
- 8
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass Spectrometry: Bottom-Up or Top-Down? https://app.cochat.ai/papers/10.1126/science.1133987
- The paper
- Chait, B. T. (2006). Mass Spectrometry: Bottom-Up or Top-Down? Science. https://doi.org/10.1126/science.1133987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.