Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The imaging of phosphorescence provides a method for monitoring oxygen distribution within the vascular system of intact tissues. Isolated rat lives were perfused through the portal vein with media containing palladium coproporphyrin, which phosphoresced and was used to image the liver at various perfusion rates. Because oxygen is a powerful quenching agent for phosphors, the transition from well-perfused liver to anoxia (no flow of oxygen) resulted in large increases of phosphorescence. During stepwise restoration of oxygen flow, the phosphorescence images showed marked heterogeneous patterns of tissue reoxygenation, which indicated that there were regional inequalities in oxygen delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)45596-2 · Cited by 592
Self-citationWilson, D. F., Rumsey, W. L., Green, T. J., & Vanderkooi, J. M. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)69126-4 · Cited by 387
Self-citationA New Method for Measuring Oxygen Concentration in Biological Systems
Vanderkooi, J. M., & Wilson, D. F. (1986) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5188-7_25 · Cited by 81
Self-citation
Research works printed but not linked: 6
- CAMPRA, J.C., LIVER BIOL PATHOBIOL 632 (1982).
- 10.1002/jcp.1041330115 · doi:10.1002/jcp.1041330115
- MATSUMURA, T, O-2 UPTAKE IN PERIPORTAL AND PERICENTRAL REGIONS OF LIVER LOBULE IN PERFUSED LIVER, AMERICAN JOURNAL OF PHYSIOLOGY 250: G800 (1986).
- VANDERKOOI, J.M., ADV EXP MED BIOL 200: 189 (1987).
- 10.1007/978-1-4684-7433-6_9 · DOI
- WILSON, D.F., ADV EXP MED BIOL 220: 121 (1988).
Cited by
Activating efficient phosphorescence from purely organic materials by crystal design
Bolton, O., Lee, K., Kim, H.-J., Lin, K. Y., & Kim, J. (2011) · Nature Chemistry · doi:10.1038/nchem.984 · Cited by 1,662
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Correlation between intraluminal oxygen gradient and radial partitioning of intestinal microbiota
Albenberg, L., Esipova, T. V., Judge, C. P., Bittinger, K., Chen, J., Laughlin, A., Grunberg, S., Baldassano, R. N., Lewis, J. D., Li, H., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.07.020 · Cited by 886
Metadata
- Authors
- Rumsey, W., Vanderkooi, J., & Wilson, D.
- Venue
- Science
- Published
- 1988-09-23
- Volume
- 241
- Issue
- 4873
- Pages
- 1649-1651
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2094866017
- Cited by
- 534
- References
- 3
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.