The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Alterations of Single Molecule Fluorescence Lifetimes in Near-Field Optical Microscopy
Abstract
Fluorescence lifetimes of single Rhodamine 6G molecules on silica surfaces were measured with pulsed laser excitation, time-correlated single photon counting, and near-field scanning optical microscopy (NSOM). The fluorescence lifetime varies with the position of a molecule relative to a near-field probe. Qualitative features of lifetime decreases are consistent with molecular excited state quenching effects near metal surfaces. The technique of NSOM provides a means of altering the environment of a single fluorescent molecule and its decay kinetics in a repeatable fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
Betzig, E., & Trautman, J. K. (1992) · Science · doi:10.1126/science.257.5067.189 · Cited by 1,808
Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Optical detection and spectroscopy of single molecules in a solid
Moerner, W. E., & Kador, L. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.2535 · Cited by 1,271
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Single pentacene molecules detected by fluorescence excitation in a p-terphenyl crystal
Orrit, M., & Bernard, J. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.2716 · Cited by 1,042
Detection of single fluorescent molecules
Brooks Shera, E., Seitzinger, N. K., Davis, L. M., Keller, R. A., & Soper, S. A. (1990) · Chemical Physics Letters · doi:10.1016/0009-2614(90)85485-u · Cited by 477
Self-citationNear-field spectroscopy of single molecules at room temperature
Trautman, J. K., Macklin, J. J., Brus, L. E., & Betzig, E. (1994) · Nature · doi:10.1038/369040a0 · Cited by 428
IV Interaction of Light with Monomolecular Dye Layers
Drexhage, K. H. (1974) · Progress in Optics · doi:10.1016/s0079-6638(08)70266-x · Cited by 406
Fluorescence spectroscopy and spectral diffusion of single impurity molecules in a crystal
Ambrose, W. P., & Moerner, W. E. (1991) · Nature · doi:10.1038/349225a0 · Cited by 357
Self-citationSingle molecule detection and photochemistry on a surface using near-field optical excitation
Ambrose, W. P., Goodwin, P. M., Martin, J. C., & Keller, R. A. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.160 · Cited by 240
Self-citationOptical Spectroscopy of Single Impurity Molecules in Solids
Moerner, W. E., & Basché, T. (1993) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199304573 · Cited by 192
Photon burst detection of single near-infrared fluorescent molecules
Soper, S. A., Mattingly, Q. L., & Vegunta, P. (1993) · Analytical Chemistry · doi:10.1021/ac00054a015 · Cited by 145
Single photon avalanche diode for single molecule detection
Li, L., & Davis, L. M. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144463 · Cited by 143
Luminescence-based sensors: microheterogeneous and temperature effects
Demas, J. N., & DeGraff, Β. A. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85236-4 · Cited by 57
Huston, A. L., & Reimann, C. T. (1991) · Chemical Physics · doi:10.1016/0301-0104(91)90039-v · Cited by 23
Cited by
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Sharper Focus for a Radially Polarized Light Beam
Dorn, R., Quabis, S., & Leuchs, G. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.233901 · Cited by 2,125
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,046
On/off blinking and switching behaviour of single molecules of green fluorescent protein
Dickson, R. M., Cubitt, A. B., Tsien, R. Y., & Moerner, W. E. (1997) · Nature · doi:10.1038/41048 · Cited by 1,342
Metadata
- Authors
- Ambrose, W. P., Goodwin, P. M., Keller, R. A., & Martin, J. C.
- Venue
- Science
- Published
- 1994-07-15
- Volume
- 265
- Issue
- 5170
- Pages
- 364-367
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1983312070
- Cited by
- 341
- References
- 15
- FWCI
- 34.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.