The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Defect Motion on an InP(110) Surface Observed with Noncontact Atomic Force Microscopy
Abstract
With an atomic force microscope operating in the noncontact mode in an ultrahigh vacuum, atomic-resolution imaging of the cleaved semi-insulating InP(110) surface has been achieved. By this method, atomic scale point defects and their motion were observed at room temperature, without the field-induced effects associated with scanning tunneling microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Giessibl, F. J. (1995) · Science · doi:10.1126/science.267.5194.68 · Cited by 1,189
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Whitman, L. J., Stroscio, J. A., Dragoset, R. A., & Celotta, R. J. (1991) · Science · doi:10.1126/science.251.4998.1206 · Cited by 274
Ebert, P., Urban, K. W., & Lagally, M. G. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.840 · Cited by 79
Scanning-tunneling-microscope tip-induced migration of vacancies on GaP(110)
Ebert, P., Lagally, M. G., & Urban, K. W. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1437 · Cited by 65
Cited by
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Nanostructured Oxides in Chemistry: Characterization and Properties
Fernández-García, M., Martínez-Arias, A., Hanson, J. C., & Rodriguez, J. A. (2004) · Chemical Reviews · doi:10.1021/cr030032f · Cited by 1,035
Theories of scanning probe microscopes at the atomic scale
Hofer, W. A., Foster, A. S., & Shluger, A. L. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1287 · Cited by 480
CHARACTERIZATION OF POLYMER SURFACES WITH ATOMIC FORCE MICROSCOPY
Magonov, S. N., & Reneker, D. H. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.175 · Cited by 444
Metadata
- Authors
- Sugawara, Y., Ohta, M., Ueyama, H., & Morita, S.
- Venue
- Science
- Published
- 1995-12-08
- Volume
- 270
- Issue
- 5242
- Pages
- 1646-1648
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2068515796
- Cited by
- 336
- References
- 8
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Defect Motion on an InP(110) Surface Observed with Noncontact Atomic Force Microscopy. https://app.cochat.ai/papers/10.1126/science.270.5242.1646
- The paper
- Sugawara, Y., Ohta, M., Ueyama, H., & Morita, S. (1995). Defect Motion on an InP(110) Surface Observed with Noncontact Atomic Force Microscopy. Science. https://doi.org/10.1126/science.270.5242.1646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.