An Integrated Nanoliter DNA Analysis Device
Abstract
A device was developed that uses microfabricated fluidic channels, heaters, temperature sensors, and fluorescence detectors to analyze nanoliter-size DNA samples. The device is capable of measuring aqueous reagent and DNA-containing solutions, mixing the solutions together, amplifying or digesting the DNA to form discrete products, and separating and detecting those products. No external lenses, heaters, or mechanical pumps are necessary for complete sample processing and analysis. Because all of the components are made using conventional photolithographic production techniques, they operate as a single closed system. The components have the potential for assembly into complex, low-power, integrated analysis systems at low unit cost. The availability of portable, reliable instruments may facilitate the use of DNA analysis in applications such as rapid medical diagnostics and point-of-use agricultural testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Accessing Genetic Information with High-Density DNA Arrays
Chee, M., Yang, R., Hubbell, E., Berno, A., Huang, X. C., Stern, D., Winkler, J., Lockhart, D. J., Morris, M. S., & Fodor, S. P. A. (1996) · Science · doi:10.1126/science.274.5287.610 · Cited by 1,489
Strand displacement amplification—an isothermal,in vitro DNA amplification technique
Walker, G. T., Fraiser, M. S., Schram, J. L., Little, M. C., Nadeau, J. G., & Malinowski, D. P. (1992) · Nucleic Acids Research · doi:10.1093/nar/20.7.1691 · Cited by 850
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Discovery and analysis of inflammatory disease-related genes using cDNA microarrays
Heller, R. A., Schena, M., Chai, A., Shalon, D., Bedilion, T., Gilmore, J., Woolley, D. E., & Davis, R. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.6.2150 · Cited by 721
Sosnowski, R. G., Tu, E., Butler, W. F., O’Connell, J. P., & Heller, M. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.4.1119 · Cited by 453
High Throughput Fingerprint Analysis of Large-Insert Clones
Marra, M. A., Kucaba, T. A., Dietrich, N. L., Green, E. D., Brownstein, B., Wilson, R. K., McDonald, K. M., Hillier, L. W., McPherson, J. D., & Waterston, R. H. (1997) · Genome Research · doi:10.1101/gr.7.11.1072 · Cited by 398
Against a Whole-Genome ShotgunPreprint
Green, P. (1997) · Genome Research · doi:10.1101/gr.7.5.410 · Cited by 153
Olson, M. V. (1995) · Science · doi:10.1126/science.270.5235.394 · Cited by 106
Ghosh, S., Karanjawala, Z. E., Hauser, E. R., Ally, D. S., Knapp, J. I., Rayman, J. B., Musick, A., Tannenbaum, J., Te, C., Shapiro, S., et al. (1997) · Genome Research · doi:10.1101/gr.7.2.165 · Cited by 95
Analysis of Biosensor Chips for Identification of Nucleic Acids
Arlinghaus, H. F., Kwoka, M. N., & Jacobson, K. B. (1997) · Analytical Chemistry · doi:10.1021/ac970267p · Cited by 71
Microfabrication technologies for integrated nucleic acid analysis.Preprint
Burke, D., Burns, M. A., & Mastrangelo, C. H. (1997) · Genome Research · doi:10.1101/gr.7.3.189 · Cited by 47
Self-citationMicrofluidic flow control using selective hydrophobic patterning
Handique, K., Gogoi, B. P., Burke, D., et al. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.284515 · Cited by 43
Self-citationFluorescence-Based Sequencing Directly from Bacterial and P1-Derived Artificial Chromosomes
Boysen, C., Simon, M. I., & Hood, L. (1997) · BioTechniques · doi:10.2144/97236bm01 · Cited by 27
Pressing ahead with human genome sequencing
Gibbs, R. A. (1995) · Nature Genetics · doi:10.1038/ng1095-121 · Cited by 27
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Systems biology: a brief overview
Kitano, H. (2002) · Science · doi:10.1126/science.1069492 · Cited by 4,265
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Metadata
- Authors
- Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., Mastrangelo, C. H., & Burke, D. T.
- Venue
- Science
- Published
- 1998-10-16
- Volume
- 282
- Issue
- 5388
- Pages
- 484-487
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2148927531
- Cited by
- 1,299
- References
- 15
- FWCI
- 47.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.