The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Separation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Abstract
A nanofluidic channel device, consisting of many entropic traps, was designed and fabricated for the separation of long DNA molecules. The channel comprises narrow constrictions and wider regions that cause size-dependent trapping of DNA at the onset of a constriction. This process creates electrophoretic mobility differences, thus enabling efficient separation without the use of a gel matrix or pulsed electric fields. Samples of long DNA molecules (5000 to ∼160,000 base pairs) were efficiently separated into bands in 15-millimeter-long channels. Multiple-channel devices operating in parallel were demonstrated. The efficiency, compactness, and ease of fabrication of the device suggest the possibility of more practical integrated DNA analysis systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A microfabricated device for sizing and sorting DNA molecules
Chou, H.-P., Spence, C., Scherer, A., & Quake, S. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.1.11 · Cited by 274
Sorting by diffusion: An asymmetric obstacle course for continuous molecular separation
Chou, C.-F., Bakajin, O., Turner, S. W. P., Duke, T. A. J., Chan, S. S., Cox, E. C., Craighead, H. G., & Austin, R. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.24.13762 · Cited by 196
Self-citationMadabhushi, R. S., Vainer, M., Dolnı́k, V., Enad, S., Barker, D. L. A., Harris, D. W., & Mansfield, E. S. (1997) · Electrophoresis · doi:10.1002/elps.1150180120 · Cited by 85
Microfabrication technologies for integrated nucleic acid analysis.Preprint
Burke, D., Burns, M. A., & Mastrangelo, C. H. (1997) · Genome Research · doi:10.1101/gr.7.3.189 · Cited by 47
Cited by
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Self-citationNanofluidics, from bulk to interfaces
Bocquet, L., & Charlaix, E. (2010) · Chem. Soc. Rev. · doi:10.1039/b909366b · Cited by 1,582
Artificial Brownian motors: Controlling transport on the nanoscale
Hänggi, P., & Marchesoni, F. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.387 · Cited by 1,573
Craighead, H. G. (2000) · Science · doi:10.1126/science.290.5496.1532 · Cited by 1,437
Self-citationMicrofluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
DNA molecules and configurations in a solid-state nanopore microscope
Li, J., Gershow, M., Stein, D., Brandin, E., & Golovchenko, J. A. (2003) · Nature Materials · doi:10.1038/nmat965 · Cited by 936
Principles and applications of nanofluidic transport
Sparreboom, W., van den Berg, A., & Eijkel, J. C. T. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.332 · Cited by 900
The 'right' size in nanobiotechnology
Whitesides, G. M. (2003) · Nature Biotechnology · doi:10.1038/nbt872 · Cited by 843
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Nanofluidics: what is it and what can we expect from it?
Eijkel, J. C. T., & Berg, A. V. D. (2005) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0012-9 · Cited by 696
Future lab-on-a-chip technologies for interrogating individual molecules
Craighead, H. (2006) · Nature · doi:10.1038/nature05061 · Cited by 672
Self-citationMicrofluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Concentration Polarization and Nonlinear Electrokinetic Flow near a Nanofluidic Channel
Kim, S. J., Wang, Y.-C., Lee, J. H., Jang, H., & Han, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.044501 · Cited by 555
Self-citationStreaming Currents in a Single Nanofluidic Channel
van der Heyden, F. H. J., Stein, D., & Dekker, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.116104 · Cited by 543
Nanofluidic Ion Transport through Reconstructed Layered Materials
Raidongia, K., & Huang, J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308167f · Cited by 523
Single-nucleotide discrimination in immobilized DNA oligonucleotides with a biological nanopore
Stoddart, D., Heron, A. J., Mikhailova, E., Maglia, G., & Bayley, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901054106 · Cited by 482
Diffusion in Confined Geometries
Burada, P. S., Hänggi, P., Marchesoni, F., Schmid, G., & Talkner, P. (2009) · ChemPhysChem · doi:10.1002/cphc.200800526 · Cited by 367
Fu, J., Schoch, R. B., Stevens, A. L., Tannenbaum, S. R., & Han, J. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.206 · Cited by 334
Self-citationHnatovsky, C., Taylor, R. S., Simova, E., Rajeev, P. P., Rayner, D. M., Bhardwaj, V. R., & Corkum, P. B. (2006) · Applied Physics A · doi:10.1007/s00339-006-3590-4 · Cited by 330
Micro- and nanofluidics for DNA analysis
Tegenfeldt, J. O., Prinz, C., Huang, R. L., Austin, R. H., Chou, S. Y., Cox, E. C., Sturm, J. C., & Cao, H. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2526-0 · Cited by 320
Nanofabrication: Conventional and nonconventional methods
Chen, Y., & Pépin, A. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200101)22:2<187::aid-elps187>3.0.co;2-0 · Cited by 301
The interplay between apparent viscosity and wettability in nanoconfined water
Ortiz-Young, D., Chiu, H.-C., Kim, S., Voïtchovsky, K., & Riedo, E. (2013) · Nature Communications · doi:10.1038/ncomms3482 · Cited by 293
Molecular sieving using nanofilters: Past, present and future
Han, J., Fu, J., & Schoch, R. B. (2008) · Lab Chip · doi:10.1039/b714128a · Cited by 293
Self-citationCapillary filling speed of water in nanochannels
Tas, N. R., Haneveld, J., Jansen, H. V., Elwenspoek, M., & van den Berg, A. (2004) · Applied Physics Letters · doi:10.1063/1.1804602 · Cited by 288
Dissipative Particle Dynamics (DPD): An Overview and Recent Developments
Liu, M. B., Liu, G. R., Zhou, L. W., & Chang, J. Z. (2015) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9124-x · Cited by 273
Bae, W., Kim, H. N., Kim, D., Park, S., Jeong, H. E., & Suh, K. (2014) · Advanced Materials · doi:10.1002/adma.201303412 · Cited by 265
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Metadata
- Authors
- Han, J., & Craighead, H. G.
- Venue
- Science
- Published
- 2000-05-12
- Volume
- 288
- Issue
- 5468
- Pages
- 1026-1029
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2112907243
- Cited by
- 924
- References
- 5
- FWCI
- 29.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.