The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Light-Addressable Potentiometric Sensor for Biochemical Systems
Abstract
Numerous biochemical reactions can be measured potentiometrically through changes in p H, redox potential, or transmembrane potential. An alternating photocurrent through an electrolyte-insulator-semiconductor interface provides a highly sensitive means to measure such potential changes. A spatially selectable photoresponse permits the determination of a multiplicity of chemical events with a single semiconductor device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Biosensors: fundamentals and applications
Turner, A. P. F., Karube, I., Wilson, G. S., & Worsfold, P. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85361-1 · Cited by 1,320
Bousse, L., De Rooij, N. F., & Bergveld, P. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21284 · Cited by 574
Jack bean urease: the first nickel enzyme
Blakeley, R. L., & Zerner, B. (1984) · Journal of Molecular Catalysis · doi:10.1016/0304-5102(84)80014-0 · Cited by 201
Ion-Sensitive Field Effect Transistors and Related Devices
ZEMEL, J. N. (1975) · Analytical Chemistry · doi:10.1021/ac60352a020 · Cited by 79
Reversibly immobilized glucose oxidase in the amperometric flow-injection determination of glucose
de Alwis, W. U., Hill, B. S., Meiklejohn, B. I., & Wilson, G. S. (1987) · Analytical Chemistry · doi:10.1021/ac00149a012 · Cited by 32
Ion-sensitive membranes fabricated by the ion-beam technique
Pham, M. T., & Hoffmann, W. E. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)80012-8 · Cited by 26
Stability of silicon nitride/silicon dioxide/silicon electrodes used in pH microelectronic sensors
Chauvet, F., Amari, A., & Martínez, A. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)85021-0 · Cited by 20
Cited by
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Pathogen detection: A perspective of traditional methods and biosensors
Lazcka, O., Campo, F. J. D., & Muñoz, F. X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.036 · Cited by 1,500
Biosensors for detection of pathogenic bacteria
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00039-1 · Cited by 931
Metadata
- Authors
- Hafeman, D. G., Parce, J. W., & McConnell, H. M.
- Venue
- Science
- Published
- 1988-05-27
- Volume
- 240
- Issue
- 4856
- Pages
- 1182-1185
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2034179902
- Cited by
- 709
- References
- 8
- FWCI
- 11.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.