The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy
Abstract
A high-temperature superconducting-receiver system for use in nuclear magnetic resonance (NMR) microscopy is described. The scaling behavior of sources of sample and receiver-coil noise is analyzed, and it is demonstrated that Johnson, or thermal, noise in the receiver coil is the factor that limits resolution. The behavior of superconductors in the environment of an NMR experiment is examined, and a prototypical system for imaging biological specimens is discussed. Preliminary spin-echo images are shown, and the ultimate limits of the signal-to-noise ratio of the probe are investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Cited by
High-Resolution Microcoil 1 H-NMR for Mass-Limited, Nanoliter-Volume Samples
Olson, D. L., Peck, T. L., Webb, A. G., Magin, R. L., & Sweedler, J. V. (1995) · Science · doi:10.1126/science.270.5244.1967 · Cited by 503
Structural Investigations of Glycoconjugates at High Sensitivity
Mechref, Y., & Novotny, M. V. (2002) · Chemical Reviews · doi:10.1021/cr0103017 · Cited by 341
Micro MRI of the mouse brain using a novel 400 MHz cryogenic quadrature RF probe
Baltes, C., Radzwill, N., Bosshard, S., Marek, D., & Rudin, M. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1396 · Cited by 152
Performance of a 200‐MHz cryogenic RF probe designed for MRI and MRS of the murine brain
Ratering, D., Baltes, C., Nordmeyer‐Massner, J., Marek, D., & Rudin, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21629 · Cited by 91
Use of a DC SQUID receiver preamplifier in a low field MRI system
Seton, H. C., Bussell, D. M., Hutchison, J. M. S., & Lurie, D. J. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.403276 · Cited by 28
Metadata
- Authors
- Black, R. D., Early, T. A., Roemer, P. B., Mueller, O. M., Mogro-Campero, A., Turner, L. G., & Johnson, G. A.
- Venue
- Science
- Published
- 1993-02-05
- Volume
- 259
- Issue
- 5096
- Pages
- 793-795
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2063821036
- Cited by
- 206
- References
- 1
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy. https://app.cochat.ai/papers/10.1126/science.8430331
- The paper
- Black, R. D., Early, T. A., Roemer, P. B., Mueller, O. M., Mogro-Campero, A., Turner, L. G., & Johnson, G. A. (1993). A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy. Science. https://doi.org/10.1126/science.8430331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.