The DOI matches its Crossref record; 62 of the 63 references it cites were found in a registry or an index.
A Fermi-degenerate three-dimensional optical lattice clock
Open accessAbstract
Making a denser optical lattice clock: Some of today's most advanced clocks are made up of large numbers of atoms lined up in a one-dimensional (1D) optical lattice. The numbers improve clock stability, but atomic interactions can limit accuracy. Campbell et al. loaded their fermionic strontium atoms into a 3D optical lattice. The low temperatures and strong interactions ensured that the atoms avoided one another, resulting in a neat pattern where each lattice site was occupied by exactly one atom. This ordering reduced the influence of interactions on the clock's accuracy, whereas the high density of atoms enabled by the 3D geometry improved the precision. Science , this issue p. 90
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Some recent techniques such as three-dimensional optical lattice clocks [104] allow to greatly improve the integration times necessary to attain some specified accuracy for the clock.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [104]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum phase transition from a superfluid to a Mott insulator in a gas of ultracold atoms
Greiner, M., Mandel, O., Esslinger, T., Hänsch, T. W., & Bloch, I. (2002) · Nature · doi:10.1038/415039a · Cited by 5,935 · cited 2×
“We load a two-spin degenerate Fermi gas into the ground band of a 3D optical lattice in the Mott-insulating regime where the number of doubly occupied sites is suppressed [66, 83, 146].”
BackgroundSimulation modeling and analysis
(1999) · Journal of Manufacturing Systems · doi:10.1016/s0278-6125(99)90119-x · Cited by 3,833
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationOnset of Fermi Degeneracy in a Trapped Atomic Gas
DeMarco, B., & Jin, D. S. (1999) · Science · doi:10.1126/science.285.5434.1703 · Cited by 1,238 · cited 1×
“In 1999, Debbie Jin and student Brian deMarco produced the first degenerate Fermi gas of ultracold atoms [48].”
BackgroundAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 6×
“For a given lattice laser frequency, we measure the differential ac Stark shift using four interleaved digital servos that lock the clock laser frequency to the atomic resonance for alternating high and low lattice intensities and mF = ±9/2 spin states [23, 121, 56].”
BackgroundMethodInfluentialSelf-citationA Mott insulator of fermionic atoms in an optical lattice
Jördens, R., Strohmaier, N., Günter, K., Moritz, H., & Esslinger, T. (2008) · Nature · doi:10.1038/nature07244 · Cited by 1,049 · cited 6×
“As the lattice depth increases, multiple occupancies are suppressed when 12J U and kBTlattice EF U , where Tlattice is the temperature in the lattice [83, 146].”
BackgroundMethodInfluentialObservation of dipolar spin-exchange interactions with lattice-confined polar molecules
Yan, B., Moses, S. A., Gadway, B., Covey, J. P., Hazzard, K. R. A., Rey, A. M., Jin, D., & Ye, J. (2013) · Nature · doi:10.1038/nature12483 · Cited by 910 · cited 2×
“Future studies of dipolar interactions in quantum degenerate lattice clocks will not only be necessary for clock accuracy but will also provide powerful connections to other physical systems based on polar molecules [173, 121], Rydberg gases [143], and magnetic atoms [5, 47, 84, 31].”
BackgroundSelf-citationAn Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 10×
“For a given lattice laser frequency, we measure the differential ac Stark shift using four interleaved digital servos that lock the clock laser frequency to the atomic resonance for alternating high and low lattice intensities and mF = ±9/2 spin states [23, 121, 56].”
BackgroundMethodInfluentialSelf-citationTunable two-dimensional arrays of single Rydberg atoms for realizing quantum Ising models
Labuhn, H., Barredo, D., Ravets, S., de Léséleuc, S., Macrì, T., Lahaye, T., & Browaeys, A. (2016) · Nature · doi:10.1038/nature18274 · Cited by 765 · cited 1×
“Future studies of dipolar interactions will not only be necessary for clock accuracy, but will also provide insight into long-range quantum spin systems in a regime distinct from those explored by polar molecules [173, 121], Rydberg gases [143, 98], and highly magnetic atoms [5, 47, 84, 31].”
Background
Flagged first, then by citations
1 of the 63 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- J. G. Dick in Proceedings of the 19th Precise Time and Time Interval Applications and Planning Meeting (1987) pp. 133–147.
- M. Swallows “A search for the permanent electric dipole moment of mercury-199 ” thesis University of Washington Seattle WA (2007).
Cited by
Sorted by citations
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
1.5 μ m Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 575
Self-citationQuantum Simulators: Architectures and Opportunities
Altman, E., Brown, K. R., Carleo, G., Carr, L. D., Demler, E., Chin, C., DeMarco, B., Economou, S. E., Eriksson, M. A., Fu, K. C., et al. (2021) · PRX Quantum · doi:10.1103/prxquantum.2.017003 · Cited by 658
Self-citationDemonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationTools for quantum simulation with ultracold atoms in optical lattices
Schäfer, F., Fukuhara, T., Sugawa, S., Takasu, Y., & Takahashi, Y. (2020) · Nature Reviews Physics · doi:10.1038/s42254-020-0195-3 · Cited by 488
Metadata
- Authors
- Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- JILA, National Institute of Standards and Technology (NIST) and University of Colorado Boulder, 440 UCB, Boulder, CO 80309, USA.
- Corresponding author
- Campbell, S. L.
- Hutson, R. B.
- Ye, J.
- ORCID
- Venue
- Science
- Published
- 2017-10-06
- Volume
- 358
- Issue
- 6359
- Pages
- 90-94
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2949618864
- Semantic Scholar
- 51b96167c3f995faf85982f7a72342bc0de0c14a
- Cited by
- 384
- References
- 63
- Citations by year
- 2026: 8 · 2025: 33 · 2024: 35 · 2023: 36 · 2022: 49 · 2021: 38 · 2020: 50 · 2019: 68 · 2018: 61 · 2017: 6
- FWCI
- 24.82
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CU Scholar (University of Colorado Boulder) (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
- arXiv (Cornell University)
- Funders
- National Science Foundation (award287270)
- National Institute of Standards and Technology (award287271)
- Air Force Office of Scientific Research (award307994, MURI)
- Defense Sciences Office, DARPA (award287272)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical lattice clock, three-dimensional optical lattice, Fermi degeneracy, interatomic interactions, clock stability, atomic density, ultracold atoms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review