The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
An ingestible bacterial-electronic system to monitor gastrointestinal health
Open accessAbstract
Using bugs in the gut to detect blood: Bacteria are environmentally resilient and can be engineered to sense various biomolecules. Mimee et al. combined biosensor bacteria with a miniaturized wireless readout capsule to produce a minimally invasive device capable of in vivo biosensing in harsh, difficult-to-access environments (see the Perspective by Gibson and Burgell). The device successfully measured gastrointestinal bleeding in pigs. Science , this issue p. 915 ; see also p. 856
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The use of genetically engineered bacterial strains to assess the gut environment, release metabolites of interest at specific locations within the GI tract, and optimize drug metabolism appears to be on the horizon190, 191.”
From The gut Microbiome in adult and pediatric functional gastrointestinal disorders (2019) · cites this paper as [191]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kearse, M., Moir, R., Wilson, A., Stones-Havas, S., Cheung, M., Sturrock, S., Buxton, S., Cooper, A., Markowitz, S., Duran, C., et al. (2012) · Bioinform. · doi:10.1093/bioinformatics/bts199 · Cited by 19,197
Enzymatic assembly of DNA molecules up to several hundred kilobases
Gibson, D. G., Young, L., Chuang, R.-Y., Venter, J. C., Hutchison, C. A., & Smith, H. O. (2009) · Nature Methods · doi:10.1038/nmeth.1318 · Cited by 10,088
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Automated design of synthetic ribosome binding sites to control protein expression
Salis, H. M., Mirsky, E. A., & Voigt, C. A. (2009) · Nature Biotechnology · doi:10.1038/nbt.1568 · Cited by 1,844
Chung, C. T., Niemelä, S., & Miller, R. H. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.7.2172 · Cited by 1,602
Malfertheiner, P., Chan, F. K. L., & McColl, K. E. L. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60938-7 · Cited by 1,558
Lanas, Á., & Chan, F. K. L. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32404-7 · Cited by 989
Principles of genetic circuit design
Brophy, J. A. N., & Voigt, C. A. (2014) · Nature Methods · doi:10.1038/nmeth.2926 · Cited by 965
Rapid fucosylation of intestinal epithelium sustains host–commensal symbiosis in sickness
Pickard, J. M., Maurice, C. F., Kinnebrew, M. A., Abt, M. C., Schenten, D., Golovkina, T. V., Bogatyrev, S. R., Ismagilov, R. F., Pamer, E. G., Turnbaugh, P. J., et al. (2014) · Nature · doi:10.1038/nature13823 · Cited by 550
Acyl-Homoserine Lactone Quorum Sensing: From Evolution to Application
Schuster, M., Sexton, D. J., Diggle, S. P., & Greenberg, E. P. (2013) · Annual Review of Microbiology · doi:10.1146/annurev-micro-092412-155635 · Cited by 549
Consensus Recommendations for Managing Patients with Nonvariceal Upper Gastrointestinal Bleeding
Barkun, A. N., Bardou, M., Marshall, J. K., & for the Nonvariceal Upper GI Bleeding Consensus Conference Group* (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-10-200311180-00012 · Cited by 540
Hwang, I. Y., Koh, E., Wong, A., March, J. C., Bentley, W. E., Lee, Y. S., & Chang, M. W. (2017) · Nature Communications · doi:10.1038/ncomms15028 · Cited by 472
Borujeni, A. E., Channarasappa, A. S., & Salis, H. M. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt1139 · Cited by 451
Engineered bacteria can function in the mammalian gut long-term as live diagnostics of inflammation
Riglar, D. T., Giessen, T. W., Baym, M., Kerns, S. J., Niederhuber, M. J., Bronson, R. T., Kotula, J. W., Gerber, G. K., Way, J. C., & Silver, P. A. (2017) · Nature Biotechnology · doi:10.1038/nbt.3879 · Cited by 426
Mimee, M., Tucker, A. C., Voigt, C. A., & Lu, T. K. (2015) · Cell Systems · doi:10.1016/j.cels.2015.06.001 · Cited by 387
Self-citationProgrammable bacteria detect and record an environmental signal in the mammalian gut
Kotula, J. W., Kerns, S. J., Shaket, L. A., Siraj, L., Collins, J. J., Way, J. C., & Silver, P. A. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1321321111 · Cited by 350
Self-citationA human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342
Synthetic biology devices for in vitro and in vivo diagnostics
Slomovic, S., Pardee, K., & Collins, J. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508521112 · Cited by 320
Self-citationEngineering bacterial thiosulfate and tetrathionate sensors for detecting gut inflammation
Daeffler, K. N.-M., Galley, J. D., Sheth, R. U., Ortiz-Velez, L., Bibb, C. O., Shroyer, N. F., Britton, R. A., & Tabor, J. J. (2017) · Molecular Systems Biology · doi:10.15252/msb.20167416 · Cited by 304
Courbet, A., Endy, D., Renard, É., Molina, F., & Bonnet, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3601 · Cited by 274
Oral, ultra–long-lasting drug delivery: Application toward malaria elimination goals
Bellinger, A. M., Jafari, M., Grant, T. M., Zhang, S., Slater, H., Wenger, E. A., Mo, S., Lee, Y. L., Mazdiyasni, H., Kogan, L., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aag2374 · Cited by 263
Self-citationDevelopment of an oral once-weekly drug delivery system for HIV antiretroviral therapy
Kirtane, A. R., Abouzid, O., Minahan, D., Bensel, T., Hill, A. L., Selinger, C., Bershteyn, A., Craig, M., Mo, S. S., Mazdiyasni, H., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02294-6 · Cited by 227
Self-citationAn Ingestible Sensor for Measuring Medication Adherence
Hafezi, H., Robertson, T. L., Moon, G., Au-Yeung, K. Y., Zdeblick, M. J., & Savage, G. M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2341272 · Cited by 226
Engineered Regulatory Systems Modulate Gene Expression of Human Commensals in the Gut
Lim, B., Zimmermann, M., Barry, N. A., & Goodman, A. L. (2017) · Cell · doi:10.1016/j.cell.2017.03.045 · Cited by 219
Rockey, D. C., Koch, J., Cello, J. P., Sanders, L. L., & McQuaid, K. R. (1998) · New England Journal of Medicine · doi:10.1056/nejm199807163390303 · Cited by 172
A 0.18- $muhbox m$ CMOS Bioluminescence Detection Lab-on-Chip
Eltoukhy, H., Salama, K. N., & El-Gamal, A. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.869785 · Cited by 141
A novel ingestible electronic drug delivery and monitoring device
Schaar, P. J. V. D., Dijksman, J., Gast, H. S. B.-D., Shimizu, J., van Lelyveld, N., Zou, H., Iordanov, V. P., Wanke, C., & Siersema, P. D. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.03.170 · Cited by 119
An integrated CMOS quantitative-polymerase-chain-reaction lab-on-chip for point-of-care diagnostics
Norian, H., Field, R. M., Kymissis, I., & Shepard, K. L. (2014) · Lab on a Chip · doi:10.1039/c4lc00443d · Cited by 112
Lechardeur, D., Cesselin, B., Liebl, U., Vos, M. H., Fernandez, A., Brun, C., Gruss, A., & Gaudu, P. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.297531 · Cited by 93
The Evolution of the Bacterial Luciferase Gene Cassette (lux) as a Real-Time Bioreporter
Close, D. M., Xu, T., Smartt, A. E., Rogers, A., Crossley, R., Price, S. L., Ripp, S. A., & Sayler, G. S. (2012) · Sensors · doi:10.3390/s120100732 · Cited by 83
Roggo, C., & van der Meer, J. R. (2017) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.11.023 · Cited by 78
21.1 Nanowatt circuit interface to whole-cell bacterial sensors
Nadeau, P., Mimee, M., Carim, S., Lu, T. K., & Chandrakasan, A. P. (2017) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2017.7870406 · Cited by 27
Self-citationA CMOS-Microfluidic Chemiluminescence Contact Imaging Microsystem
Singh, R. R., Leng, L., Günther, A., & Genov, R. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2214182 · Cited by 24
Wang, H. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2259402 · Cited by 21
A dual component heme biosensor that integrates heme transport and synthesis in bacteria
Nobles, C. L., Clark, J. R., Green, S. I., & Maresso, A. W. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.07.011 · Cited by 17
Cited by
Sorted by citations
Choi, K. R., Jang, W. D., Yang, D., Cho, J. S., Park, D., & Lee, S. Y. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2019.01.003 · Cited by 579
Engineered living biomaterials
Rodrigo‐Navarro, A., Sankaran, S., Dalby, M. J., del Campo, A., & Salmerón‐Sánchez, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00350-8 · Cited by 512
Connected healthcare: Improving patient care using digital health technologies
Awad, A., Trenfield, S. J., Pollard, T. D., Ong, J. J., Elbadawi, M., McCoubrey, L. E., Goyanes, A., Gaisford, S., & Basit, A. W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113958 · Cited by 405
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Materials design by synthetic biology
Tang, T., An, B., Huang, Y., Vasikaran, S., Wang, Y., Jiang, X., Lu, T. K., & Zhong, C. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-00265-w · Cited by 406
Self-citation
Metadata
- Authors
- Mimee, M., Nadeau, P., Hayward, A., Carim, S., Flanagan, S., Jerger, L., Collins, J., McDonnell, S., Swartwout, R., Citorik, R. J., Bulović, V., Langer, R., Traverso, G., Chandrakasan, A. P., & Lu, T. K.
- Affiliations
- Massachusetts Institute of Technology (US)
- Koch Institute for Integrative Cancer Research At MIT (US)
- Harvard University (US)
- Koch Institute for Integrative Cancer Research, MIT, Cambridge, MA 02139, USA.
- Brigham and Women's Hospital (US)
- Corresponding author
- Mimee, Mark
- Nadeau, Phillip
- Chandrakasan, Anantha P.
- Lu, Timothy K.
- ORCID
- Venue
- Science
- Published
- 2018-05-25
- Volume
- 360
- Issue
- 6391
- Pages
- 915-918
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC6430580
- OpenAlex
- W2803662842
- Cited by
- 606
- References
- 35
- Citations by year
- 2026: 58 · 2025: 106 · 2024: 75 · 2023: 81 · 2022: 76 · 2021: 84 · 2020: 67 · 2019: 42 · 2018: 17
- FWCI
- 20.97
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
- PMC
- Funders
- National Institutes of Health (EB-000244)
- Office of Naval Research Global (N00014-13-1-0424)
- National Science Foundation (1522074)
- Hong Kong Innovation and Technology Fund (ITS/195/14FP)
- Center for Microbiome Informatics and Therapeutics (15127713)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- gastrointestinal bleeding diagnosis, gastrointestinal disease diagnosis, porcine model, implantable electronics
- MeSH terms
- Animals, Gastrointestinal Diseases, Heme, Gastrointestinal Hemorrhage, Monitoring, Physiologic, Swine, Biosensing Techniques, Probiotics, Gastrointestinal Tract, Electrical Equipment and Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review