The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Controlled tough bioadhesion mediated by ultrasound
Abstract
Tough bioadhesion has important implications in engineering and medicine but remains challenging to form and control. We report an ultrasound (US)–mediated strategy to achieve tough bioadhesion with controllability and fatigue resistance. Without chemical reaction, the US can amplify the adhesion energy and interfacial fatigue threshold between hydrogels and porcine skin by up to 100 and 10 times. Combined experiments and theoretical modeling suggest that the key mechanism is US-induced cavitation, which propels and immobilizes anchoring primers into tissues with mitigated barrier effects. Our strategy achieves spatial patterning of tough bioadhesion, on-demand detachment, and transdermal drug delivery. This work expands the material repertoire for tough bioadhesion and enables bioadhesive technologies with high-level controllability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationNam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604
Noninvasive hippocampal blood-brain barrier opening in Alzheimer's disease with focused ultrasound.
Rezai, A. R., Ranjan, M., D’Haese, P.-F., Haut, M. W., Carpenter, J., Najib, U., Mehta, R. I., Chazen, J. L., Zibly, Z., Yates, J. R., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002571117 · Cited by 365
Cited by
Recent progress of antibacterial hydrogels in wound dressings
Jia, B., Li, G., Cao, E., Luo, J., Zhao, X., & Huang, H. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100582 · Cited by 320
Design of biopolymer-based hemostatic material: Starting from molecular structures and forms
Zou, C.-Y., Li, Q.-J., Hu, J.-J., Song, Y.-T., Zhang, Q.-Y., Nie, R., Li-Ling, J., & Xie, H.-Q. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100468 · Cited by 87
Tough adhesion enhancing strategies for injectable hydrogel adhesives in biomedical applications
Ouyang, C., Yu, H., Wang, L., Ni, Z., Liu, X., Shen, D., Yang, J., Shi, K., & Wang, H. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.102982 · Cited by 82
Metadata
- Authors
- Ma, Z., Bourquard, C., Gao, Q., Jiang, S., De Iure-Grimmel, T., Huo, R., Li, X., He, Z., Yang, Z., Yang, G., Wang, Y., Lam, E., Gao, Z.-H., Supponen, O., & Li, J.
- Venue
- Science
- Published
- 2022-08-12
- Volume
- 377
- Issue
- 6607
- Pages
- 751-755
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4293298399
- Cited by
- 244
- References
- 4
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlled tough bioadhesion mediated by ultrasound. https://app.cochat.ai/papers/10.1126/science.abn8699
- The paper
- Ma, Z., Bourquard, C., Gao, Q., Jiang, S., De Iure-Grimmel, T., Huo, R., Li, X., He, Z., Yang, Z., Yang, G., Wang, Y., Lam, E., Gao, Z.-H., Supponen, O., & Li, J. (2022). Controlled tough bioadhesion mediated by ultrasound. Science. https://doi.org/10.1126/science.abn8699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.