Hybrid EEG/EOG-based brain/neural hand exoskeleton restores fully independent daily living activities after quadriplegia
Open accessThe DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
A noninvasive, hybrid brain/neural hand exoskeleton restored intuitive control of grasping motion, restoring independent activities to quadriplegics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Common wearable techniques include electroencephalography (EEG),[281,282] surface electromyography (sEMG),[283,284] and electrooculography (EOG),[285] which capture the electrical activity of the brain, muscles, and eye movements respectively.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [285]
In the citing paper
“As the most common brain signal in clinical applications, EEG has been widely utilized in prosthetics and other HMI applications.[285,399]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [285]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [4]
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Brain–machine interface in chronic stroke rehabilitation: A controlled study
Ramos‐Murguialday, A., Broetz, D., Rea, M., Läer, L., Yilmaz, Ö., Brasil, F. L., Liberati, G., Curado, M. R., Garcia‐Cossio, E., Vyziotis, A., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23879 · Cited by 994
Self-citationGlobal prevalence and incidence of traumatic spinal cord injury
Fehlings, M., Singh, A., Tetreault, L., Kalsi-Ryan, S., & Nouri, A. (2014) · Clinical Epidemiology · doi:10.2147/clep.s68889 · Cited by 945
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
(2014) · Dove Medical Press (Taylor and Francis Group) · Cited by 468
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Brain‐computer interfaces for post‐stroke motor rehabilitation: a meta‐analysis
Cervera, M. A., Soekadar, S. R., Ushiba, J., Millán, J. D. R., Liu, M., Birbaumer, N., & Garipelli, G. (2018) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.544 · Cited by 572
Self-citationWu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Noninvasive neuroimaging enhances continuous neural tracking for robotic device control
Edelman, B. J., Meng, J., Suma, D., Zurn, C., Nagarajan, E., Baxter, B. S., Cline, C. C., & He, B. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6844 · Cited by 380
Zhu, C., Chortos, A., Wang, Y., Pfattner, R., Lei, T., Hinckley, A. C., Pochorovski, I., Yan, X., To, J. W.-F., Oh, J. Y., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0041-0 · Cited by 356
Metadata
- Authors
- Soekadar, S. R., Witkowski, M., Gómez, C., Opisso, E., Medina, J., Cortese, M., Cempini, M., Carrozza, M. C., Cohen, L. G., Birbaumer, N., & Vitiello, N.
- Affiliations
- Universitätsklinikum Tübingen (DE)
- Institut Guttmann (ES)
- Hospital de Neurorehabilitació Institut Guttmann, Barcelona, Spain.
- Scuola Superiore Sant'Anna (IT)
- National Institutes of Health (US)
- IRCCS San Camillo Hospital (IT)
- Corresponding author
- Soekadar, S. R.
- ORCID
- Venue
- Science Robotics
- Published
- 2016-12-06
- Volume
- 1
- Issue
- 1
- ISSN
- 2470-9476 (ISSN-L)
- OpenAlex
- W2559904797
- Cited by
- 242
- References
- 39
- Citations by year
- 2026: 14 · 2025: 30 · 2024: 26 · 2023: 22 · 2022: 30 · 2021: 28 · 2020: 34 · 2019: 26 · 2018: 20 · 2017: 11 · 2016: 1
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- green
- zenodo.org
- Licence
- other-oa
- Locations
- Science Robotics (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, neural control, hand exoskeleton, tetraplegia, paraplegia, activities of daily living, assistive technology, upper limb paralysis
- MeSH terms
- Exoskeleton Device, Activities of Daily Living, Adolescent, Adult, Electroencephalography, Electrooculography, Female, Hand, Humans, Male, Motor Skills, Quadriplegia, Spinal Cord Injuries, Hand Strength, Young Adult, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.