The DOI matches its Crossref record.
Total-body imaging: Transforming the role of positron emission tomography
Open accessAbstract
The first total-body positron emission tomography (TB-PET) scanner represents a radical change for experimental medicine and diagnostic health care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
Self-citationFirst Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722
Self-citationImmunoPET: Concept, Design, and Applications
Wei, W., Rosenkrans, Z. T., Liu, J., Huang, G., Luo, Q.-Y., & Cai, W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00738 · Cited by 484
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
“The sensitivity gain offered by long-AFOV PET scanners opens up new possibilities for numerous research and clinical applications, including PET imaging with a much lower injected dose, late-timepoint imaging, very fast imaging, and simultaneous total-body dynamic PET image acquisition (8,9).”
BackgroundSelf-citationMolecular imaging in oncology: Current impact and future directions
Rowe, S. P., & Pomper, M. G. (2022) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21713 · Cited by 337
Advances in PET imaging of cancer
Schwenck, J., Sonanini, D., Cotton, J. M., Rammensee, H.-G., la Fougère, C., Zender, L., & Pichler, B. J. (2023) · Nature Reviews Cancer · doi:10.1038/s41568-023-00576-4 · Cited by 312
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Self-citationPushing the Limits in Time-of-Flight PET Imaging
Lecoq, P. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2756674 · Cited by 302
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
“of the entire body in a minute or less [57].”
BackgroundSelf-citationAdvanced molecular imaging for the characterisation of complex medicines
Yilmaz, D., Sharp, P. S., Main, M. J., & Simpson, P. B. (2022) · Drug Discovery Today · doi:10.1016/j.drudis.2022.03.001 · Cited by 5
Metadata
- Authors
- Cherry, S. R., Badawi, R. D., Karp, J. S., Moses, W. W., Price, P., & Jones, T.
- Venue
- Science Translational Medicine
- Published
- 2017-03-15
- Volume
- 9
- Issue
- 381
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2596649560
- Cited by
- 251
- References
- 0
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.