Detection of Human Immunodeficiency Virus Antibodies in Oral Fluids
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Oral fluids, including saliva, gingival crevicular fluid, and mucosal transudates have been widely used for monitoring drugs, hormones, and a variety of other molecules and chemical substances for over 50 years ([34][1], [35][2], [53][3], [54][4],[68][5]). During the past decade, the use of oral
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mandel, I. D. (1990) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1990.tb00809.x · Cited by 305 · cited 1×
“Oral fluids, including saliva, gingival crevicular fluid, and mucosal transudates have been widely used for monitoring drugs, hormones, and a variety of other molecules and chemical substances for over 50 years (34, 35, 53, 54, 68).”
Background
Cited by
Saliva specimen: A new laboratory tool for diagnostic and basic investigation
Chiappin, S., Antonelli, G., Gatti, R., & De Palo, E. F. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.04.011 · Cited by 828
“Oral fluid collection devices, designed for this purpose, are commercially available [60].”
BackgroundSalivary diagnostics powered by nanotechnologies, proteomics and genomics
Wong, D. T. (2006) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2006.0180 · Cited by 367
Role of Salivary Biomarkers in Oral Cancer Detection
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2018.05.002 · Cited by 286
Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics
Malon, R. S. P., Sadir, S., Balakrishnan, M., & Córcoles, E. P. (2014) · BioMed Research International · doi:10.1155/2014/962903 · Cited by 260
“Although saliva sampling using oral fluid collectors and commercial devices is generally safe and convenient to use and provides sufficient homogeneous sample with low viscosity, it still presents several shortcomings such as (i) the requirement of supervision; (ii) the need to follow the procedures carefully to ensur…”
BackgroundApplication of microchip assay system for the measurement of C-reactive protein in human saliva
Christodoulides, N., Mohanty, S., Miller, C. S., Langub, M. C., Floriano, P. N., Dharshan, P., Ali, M. F., Bernard, B., Romanovicz, D., Anslyn, E., et al. (2005) · Lab on a Chip · doi:10.1039/b414194f · Cited by 242
Collection, Storage, and Processing of Saliva Samples for Downstream Molecular Applications
Henson, B. S., & Wong, D. T. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60761-820-1_2 · Cited by 203
“For example, rapid pointof-care HIV tests utilize saliva, gingival crevicular fluid, or oral mucosal fluid to rapidly provide test results to patients (17, 18).”
BackgroundMucosal and plasma IgA from HIV-exposed seronegative individuals neutralize a primary HIV-1 isolate
Devito, C., Hinkula, J., Kaul, R., Lopalco, L., Bwayo, J. J., Plummer, F., Clerici, M., & Broliden, K. (2000) · AIDS · doi:10.1097/00002030-200009080-00006 · Cited by 192
Low-cost tools for diagnosing and monitoring HIV infection in low-resource settings
Wu, G., & Zaman, M. H. (2012) · Bulletin of the World Health Organization · doi:10.2471/blt.12.102780 · Cited by 190
Chemical analysis in saliva and the search for salivary biomarkers – a tutorial review
Ngamchuea, K., Chaisiwamongkhol, K., Batchelor-McAuley, C., & Compton, R. G. (2018) · The Analyst · doi:10.1039/c7an01571b · Cited by 164
A Review on Saliva-Based Health Diagnostics: Biomarker Selection and Future Directions
Kumari, S., Samara, M., Ampadi Ramachandran, R., Gosh, S., George, H., Wang, R., Pesavento, R. P., & Mathew, M. T. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-023-00090-z · Cited by 95
Gulati, P., Singh, A. K., Yadav, A. K., Pasbola, K., Pandey, P., Sharma, R., Thakar, A., & Solanki, P. R. (2024) · Nanoscale Advances · doi:10.1039/d3na00682d · Cited by 47
Metadata
- Authors
- Hodinka, R. L., Nagashunmugam, T., & Malamud, D.
- Venue
- Clinical Diagnostic Laboratory Immunology
- Publisher
- American Society for Microbiology
- Published
- 1998-07
- Volume
- 5
- Issue
- 4
- Pages
- 419-426
- ISSN
- 1071-412X (ISSN-L)
- 1098-6588
- OpenAlex
- W2151082255
- Cited by
- 120
- References
- 1
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.