Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
SUMMARY: This review article introduces the significance of testing of volatile organic compounds (VOCs) in clinical samples and summarizes important features of some of the technologies. Compared to other human diseases such as cancer, studies on VOC analysis in cases of infectious diseases are limited. Here, we have described results of studies which have used some of the appropriate technologies to evaluate VOC biomarkers and biomarker profiles associated with infections. The publications reviewed include important infections of the respiratory tract, gastrointestinal tract, urinary tract, and nasal cavity. The results highlight the use of VOC biomarker profiles resulting from certain infectious diseases in discriminating between infected and healthy subjects. Infection-related VOC profiles measured in exhaled breath as well as from headspaces of feces or urine samples are a source of information with respect to disease detection. The volatiles emitted in clinical matrices may on the one hand represent metabolites of the infecting pathogen or on the other hand reflect pathogen-induced host responses or, indeed, a combination of both. Because exhaled-breath samples are easy to collect and online instruments are commercially available, VOC analysis in exhaled breath appears to be a promising tool for noninvasive detection and monitoring of infectious diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Pathophysiology and Management of Pulmonary Infections in Cystic Fibrosis
Gibson, R. L., Burns, J. L., & Ramsey, B. W. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-505so · Cited by 1,633
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Aspergillosis Case-Fatality Rate: Systematic Review of the Literature
Lin, S.-J., Schranz, J., & Teutsch, S. M. (2001) · Clinical Infectious Diseases · doi:10.1086/318483 · Cited by 1,409
Establishment of infection: lessons from a versatile opportunist
Lyczak, J. B., Cannon, C. L., & Pier, G. B. (2000) · Microbes and Infection · doi:10.1016/s1286-4579(00)01259-4 · Cited by 1,341
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Cited by
Coagulase-Negative Staphylococci
Becker, K., Heilmann, C., & Peters, G. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00109-13 · Cited by 1,628
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Role of bacterial volatile compounds in bacterial biology
Audrain, B., Farag, M. A., Ryu, C.-M., & Ghigo, J.-M. (2015) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuu013 · Cited by 455
Yao, S., Ren, P., Song, R., Liu, Y., Huang, Q., Dong, J., O'Connor, B. T., & Zhu, Y. (2020) · Advanced Materials · doi:10.1002/adma.201902343 · Cited by 324
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Recent Advances in Sensing Applications of Graphene Assemblies and Their Composites
Tung, T. T., Nine, M. J., Krebsz, M., Pasinszki, T., Coghlan, C. J., Tran, D. N. H., & Losic, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702891 · Cited by 294
Acharya, B., Acharya, A., Gautam, S., Ghimire, S. P., Mishra, G., Parajuli, N., & Sapkota, B. (2020) · Molecular Biology Reports · doi:10.1007/s11033-020-05413-7 · Cited by 292
Nanomaterial-based gas sensors used for breath diagnosis
Zhou, X., Xue, Z., Chen, X., Huang, C., Bai, W., Lu, Z., & Wang, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02518a · Cited by 227
Sun, X., Shao, K., & Wang, T. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9200-6 · Cited by 211
“This advantage is helpful in monitoring clinical treatment [28].”
BackgroundMaterials and Wearable Devices for Autonomous Monitoring of Physiological Markers
Wu, W., & Haick, H. (2018) · Advanced Materials · doi:10.1002/adma.201705024 · Cited by 208
van der Schee, M. P., Paff, T., Brinkman, P., van Aalderen, W. M. C., Haarman, E. G., & Sterk, P. J. (2015) · Chest · doi:10.1378/chest.14-0781 · Cited by 203
Recent advancement in biosensors technology for animal and livestock health management
Neethirajan, S., Tuteja, S. K., Huang, S.-T., & Kelton, D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.015 · Cited by 201
Military applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194
Electronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Mei, H., Peng, J., Wang, T., Zhou, T., Zhao, H., Zhang, T., & Yang, Z. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01489-z · Cited by 177
Aghaei, S. M., Aasi, A., Farhangdoust, S., & Panchapakesan, B. (2021) · Applied Surface Science · doi:10.1016/j.apsusc.2020.147756 · Cited by 171
Jin, H., Huynh, T.-P., & Haick, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01066 · Cited by 167
A Breath Fungal Secondary Metabolite Signature to Diagnose Invasive Aspergillosis
Koo, S., Thomas, H. R., Daniels, S. D., Lynch, R. C., Fortier, S. M., Shea, M. M., Rearden, P., Comolli, J. C., Baden, L. R., & Marty, F. M. (2014) · Clinical Infectious Diseases · doi:10.1093/cid/ciu725 · Cited by 153
Azimzadeh, M., Khashayar, P., Mousazadeh, M., Daneshpour, M., Rostami, M., Goodlett, D. R., Manji, K., Fardindoost, S., Akbari, M., & Hoorfar, M. (2025) · Talanta · doi:10.1016/j.talanta.2025.127991 · Cited by 16
“Some reviews are published in the related fields discussing VOC detection [4–7], but few have explored the general concept of detecting wound infections [8], the application of VOCs for medical disease detection [9], and reporting the human skin volatilome [10,11].”
Metadata
- Authors
- Sethi, S., Nanda, R., & Chakraborty, T.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2013-07
- Volume
- 26
- Issue
- 3
- Pages
- 462-475
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- OpenAlex
- W2169063504
- Cited by
- 331
- References
- 95
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.