The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Negative Nasopharyngeal and Oropharyngeal Swabs Do Not Rule Out COVID-19
Open accessAbstract
C oronavirus disease 19 (COVID-19) has become the Public Health Emergency of International Concern.A diagnosis is made by the detection of a novel virus or genetically similar coronavirus by molecular assay in clinical specimens (1).Nasopharyngeal and oropharyngeal (NP/OP) samples are commonly used as a screening tool.Here, we reported a case of COVID-19 pneumonia diagnosed from bronchoalveolar lavage (BAL) fluid that initially had negative tests from NP/OP swabs.On 21 January 2020, a 28-year-old previously healthy Chinese man presented to Maharaj Nakorn Chiang Mai Hospital, Chiang Mai, Thailand, with a 3-day history of high-grade fever and malaise.He also complained of rhinorrhea and cough, which had already resolved.He traveled from Jinzhou, China, to Chiang Mai on 15 January 2020 by trains and airplanes, with a brief transit in Wuhan, China.After his full itinerary was identified, his case was reported to the local government health agency as a patient under investigation for COVID-19.He was admitted to an airborne infection isolation room, and NP/OP swabs were obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamming, I., Timens, W., Bulthuis, M., Lely, A., Navis, G., & van Goor, H. (2004) · The Journal of Pathology · doi:10.1002/path.1570 · Cited by 5,676 · cited 2×
“It is supported by the basic science evidence that the target functional receptor of these viruses is angiotensin-converting enzyme 2 (ACE2) (4, 5).”
BackgroundWan, Y., Shang, J., Graham, R., Baric, R. S., & Li, F. (2020) · Journal of Virology · doi:10.1128/jvi.00127-20 · Cited by 4,341
Peiris, J., Chu, C., Cheng, V., Chan, K., Hung, I., Poon, L., Law, K., Tang, B., Hon, T., Chan, C., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13412-5 · Cited by 2,375
Memish, Z. A., Al-Tawfiq, J. A., Makhdoom, H. Q., Assiri, A., Alhakeem, R. F., Albarrak, A., Alsubaie, S., Al-Rabeeah, A. A., Hajomar, W. H., Hussain, R., et al. (2014) · Journal of Infectious Diseases · doi:10.1093/infdis/jiu292 · Cited by 182
Cited by
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Diagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Diagnostic accuracy of serological tests for covid-19: systematic review and meta-analysis
Lisboa Bastos, M., Tavaziva, G., Abidi, S. K., Campbell, J. R., Haraoui, L.-P., Johnston, J. C., Lan, Z., Law, S., MacLean, E., Trajman, A., et al. (2020) · BMJ · doi:10.1136/bmj.m2516 · Cited by 832
Quantitative Detection and Viral Load Analysis of SARS-CoV-2 in Infected Patients
Yu, F., Yan, L., Wang, N., Yang, S., Wang, L., Tang, Y., Gao, G., Wang, S., Ma, C., Xie, R., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa345 · Cited by 680
Associations between blood type and COVID-19 infection, intubation, and death
Zietz, M., Zucker, J., & Tatonetti, N. P. (2020) · Nature Communications · doi:10.1038/s41467-020-19623-x · Cited by 581
Metadata
- Authors
- Winichakoon, P., Chaiwarith, R., Liwsrisakun, C., Salee, P., Goonna, A., Limsukon, A., & Kaewpoowat, Q.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2020-04-23
- Volume
- 58
- Issue
- 5
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W3008027968
- Cited by
- 327
- References
- 4
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.