Cited by 167Biosensors and Analytical DetectionMalaria Research and ControlSARS-CoV-2 detection and testing

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification

Open access

Abstract

Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.00355-10

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Sorted by citations

See all 167

Metadata

Authors
Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J.
Affiliations
  • University College London Hospitals NHS Foundation Trust (GB)
  • Eiken Chemical (Japan) (JP)
  • FIND (CH)
  • Foundation for Innovative New Diagnostics, Avenue de Budé 16, Geneva CH1202, Switzerland
Venue
Journal of Clinical Microbiology
Published
2010-08
Volume
48
Issue
8
Pages
2866-2871
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2144345536
Cited by
167
References
32
Citations by year
2026: 3 · 2025: 1 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 18 · 2020: 6 · 2019: 15 · 2018: 15 · 2017: 16 · 2016: 12 · 2015: 16 · 2014: 20 · 2013: 12 · 2012: 10
FWCI
5.10
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Microbiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
University College London
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
  • Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
Keywords
loop-mediated isothermal amplification, malaria diagnosis, Plasmodium falciparum, Plasmodium, point-of-care testing, small subunit rRNA gene, rapid molecular diagnostics
MeSH terms
DNA, Mitochondrial, Humans, Malaria, Plasmodium, Sensitivity and Specificity, Temperature, Time Factors, DNA, Protozoan, Nucleic Acid Amplification Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review