The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification
Open accessAbstract
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several studies that compared the LAMP method to microscopy, PCR and RDT, reported high sensitivity and specificity compared with microscopy or PCR in nonpregnant populations [34–37].”
From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [34]
In the citing paper
“Loop-mediated isothermal amplification (LAMP) is a newer alternative to PCR and qPCR. This method does not require DNA purification, utilizes simple instrumentation (water bath or a heat block), and can be completed in less than 1 h [33,34].”
From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Self-citationRapid Diagnostic Tests for Malaria Parasites
Moody, A. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.1.66-78.2002 · Cited by 1,418
Poon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Two Nonrecombining Sympatric Forms of the Human Malaria Parasite Plasmodium ovale Occur Globally
Sutherland, C. J., Tanomsing, N., Nolder, D., Oguike, M. C., Jennison, C., Pukrittayakamee, S., Dolecek, C., Hien, T. T., do Rosário, V. E., Arez, A. P., et al. (2010) · The Journal of Infectious Diseases · doi:10.1086/652240 · Cited by 413
Self-citationHan, E., Watanabe, R., Sattabongkot, J., Khuntirat, B., Sirichaisinthop, J., Iriko, H., Jin, L., Takeo, S., & Tsuboi, T. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02117-06 · Cited by 277
Accuracy of routine laboratory diagnosis of malaria in the United Kingdom.
Milne, L. M., Kyi, M. S., Chiodini, P. L., & Warhurst, D. C. (1994) · Journal of Clinical Pathology · doi:10.1136/jcp.47.8.740 · Cited by 228
Self-citationLee, N., Baker, J., Andrews, K. T., Gatton, M. L., Bell, D., Cheng, Q., & McCarthy, J. S. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.02557-05 · Cited by 204
Padley, D., Moody, A. H., Chiodini, P. L., & Saldanha, J. (2003) · Annals of Tropical Medicine & Parasitology · doi:10.1179/000349803125002977 · Cited by 202
Self-citationBELL, D. R., Wilson, D. W., & MARTIN, L. B. (2005) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2005.73.199 · Cited by 177
Rapid Diagnostic Tests for Malaria at Sites of Varying Transmission Intensity in Uganda
Hopkins, H., Bebell, L. M., Kambale, W., Dokomajilar, C., Rosenthal, P. J., & Dorsey, G. (2008) · The Journal of Infectious Diseases · doi:10.1086/526502 · Cited by 154
Cited by
Sorted by citations
Hofmann, N., Mwingira, F., Shekalaghe, S., Robinson, L. J., Mueller, I., & Felger, I. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001788 · Cited by 413
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowel, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 353
Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B. B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., et al. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jit184 · Cited by 288
Self-citationKersting, S., Rausch, V., Bier, F. F., & Nickisch-Rosenegk, M. V. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-99 · Cited by 288
Loop-mediated isothermal amplification (LAMP): recent progress in research and development
Mori, Y., Kanda, H., & Notomi, T. (2013) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-013-0590-0 · Cited by 268
Self-citation
Metadata
- Authors
- Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J.
- Affiliations
- University College London Hospitals NHS Foundation Trust (GB)
- Eiken Chemical (Japan) (JP)
- FIND (CH)
- Foundation for Innovative New Diagnostics, Avenue de Budé 16, Geneva CH1202, Switzerland
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2010-08
- Volume
- 48
- Issue
- 8
- Pages
- 2866-2871
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- PMC
- PMC2916605
- OpenAlex
- W2144345536
- Cited by
- 167
- References
- 32
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 18 · 2020: 6 · 2019: 15 · 2018: 15 · 2017: 16 · 2016: 12 · 2015: 16 · 2014: 20 · 2013: 12 · 2012: 10
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Microbiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University College London
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Keywords
- loop-mediated isothermal amplification, malaria diagnosis, Plasmodium falciparum, Plasmodium, point-of-care testing, small subunit rRNA gene, rapid molecular diagnostics
- MeSH terms
- DNA, Mitochondrial, Humans, Malaria, Plasmodium, Sensitivity and Specificity, Temperature, Time Factors, DNA, Protozoan, Nucleic Acid Amplification Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review