Evaluation of a Rapid and Completely Automated Real-Time Reverse Transcriptase PCR Assay for Diagnosis of Enteroviral Meningitis
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Nucleic acid amplification tests (NAATs) for enterovirus RNA in cerebrospinal fluid (CSF) have emerged as the new gold standard for diagnosis of enteroviral meningitis, and their use can improve the management and decrease the costs for caring for children with enteroviral meningitis. The Xpert EV assay (Cepheid, Sunnyvale, CA) is a rapid, fully automated real-time PCR test for the detection of enterovirus RNA that was approved by the U.S. Food and Drug Administration for in vitro diagnostic use in March 2007. In this multicenter trial we established the clinical performance characteristics of the Xpert EV assay in patients presenting with meningitis symptoms relative to clinical truth. Clinical truth for enteroviral meningitis was defined as clinical evidence of meningitis, the absence of another detectable pathogen in CSF, and detection of enterovirus in CSF either by two reference NAATs or by viral culture. A total of 199 prospectively and 235 retrospectively collected specimens were eligible for inclusion in this study. The overall prevalence of enteroviral meningitis was 26.04%. The Xpert EV assay had a sensitivity of 94.69% (90% confidence interval [CI] = 89.79 to 97.66%), specificity of 100% (90% CI = 99.07 to 100%), positive predictive value of 100%, negative predictive value of 98.17, and an accuracy of 98.62% relative to clinical truth. The Xpert EV assay demonstrated a high degree of accuracy for diagnosis of enteroviral meningitis. The simplicity and on-demand capability of the Xpert EV assay should prove to be a valuable adjunct to the evaluation of suspected meningitis cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ramers, C. (2000) · JAMA · doi:10.1001/jama.283.20.2680 · Cited by 291
ROBINSON, C. C., WILLIS, M., MEAGHER, A., GIESEKER, K. E., ROTBART, H., & GLODÉ, M. P. (2002) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-200204000-00005 · Cited by 131
Self-citationMarlowe, E. M., Novak, S. M., Dunn, J. J., Smith, A., Cumpio, J., Makalintal, E., Barnes, D., & Burchette, R. J. (2008) · Journal of Clinical Virology · doi:10.1016/j.jcv.2008.04.006 · Cited by 40 · cited 1×
“The analytical sensitivity and specificity of the Xpert EV assay relative to other NAATs for detection of enterovirus RNA in CSF have been previously published (4, 5, 18).”
MethodNigrovic, L. E., Malley, R., Agrawal, D., & Kuppermann, N. (2010) · Clinical Infectious Diseases · doi:10.1086/656919 · Cited by 29
Cited by
Poritz, M. A., Blaschke, A. J., Byington, C. L., Allen, L., Nilsson, K., Jones, D. E., Thatcher, S. A., Robbins, T., Lingenfelter, B., Amiott, E., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026047 · Cited by 429
Viral (aseptic) meningitis: A review.
Wright, W. F., Pinto, C. N., Palisoc, K., & Baghli, S. (2019) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2019.01.050 · Cited by 116
Laboratory diagnosis of central nervous system infection
He, T., Kaplan, S., Kamboj, M., & Tang, Y.-W. (2016) · Current Infectious Disease Reports · doi:10.1007/s11908-016-0545-6 · Cited by 81
Self-citationBlaschke, A. J., Holmberg, K. M., Daly, J. A., Leber, A. L., Dien Bard, J., Korgenski, E. K., Bourzac, K. M., & Kanack, K. J. (2018) · Journal of clinical microbiology · doi:10.1128/jcm.00277-18 · Cited by 57
“One infant had two pathogens (EV and HPeV) detected.”
BackgroundInfluentialAronson, P. L., Lyons, T. W., Cruz, A. T., Freedman, S. B., Okada, P. J., Fleming, A. H., Arms, J. L., Thompson, A. D., Schmidt, S. M., Louie, J., et al. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2017.06.021 · Cited by 26
“Because the enterovirus PCR test is currently only approved by the US Food and Drug Administration for testing CSF, we did not extract data related to the use of this PCR test on nonapproved sample types.(15) Infants with a positive enterovirus PCR test result were classified as having an enteroviral infection.”
Metadata
- Authors
- Nolte, F. S., Rogers, B. B., Tang, Y.-W., Oberste, M. S., Robinson, C. C., Kehl, K. S., Rand, K. A., Rotbart, H. A., Romero, J. R., Nyquist, A.-C., & Persing, D. H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2011-02
- Volume
- 49
- Issue
- 2
- Pages
- 528-533
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2156224834
- Cited by
- 60
- References
- 4
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.