Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 341

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry

Open access
Ferreira, Laura, Sánchez-Juanes, Fernando, González-Ávila, Magdalena, Cembrero-Fuciños, David, Herrero-Hernández, Ana, González-Buitrago, José Manuel, Muñoz-Bellido, Juan Luis·2010·Journal of Clinical Microbiology

Abstract

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been suggested as a reliable method for bacterial identification from cultures. Direct analysis of clinical samples might increase the usefulness of this method, shortening the time for microorganism identification. We compared conventional methods for the diagnosis of urinary tract infections (UTIs) and identification of the urinary tract pathogens (automated screening, plate cultures, and identification based on biochemical characteristics) and a fast method based on conventional screening and MALDI-TOF MS. For this latter method, 4 ml of urine was centrifuged at a low-revolution setting (2,000 × g ) to remove leukocytes and then at high revolutions (15,500 × g ) to collect bacteria. The pellet was washed and then applied directly to the MALDI-TOF MS plate. Two hundred sixty urine samples, detected as positive by the screening device (UF-1000i), were processed by culture and MALDI-TOF MS. Twenty samples were positive in the screening device but negative in culture, and all of them were also negative by MALDI-TOF MS. Two-hundred thirty-five samples displayed significant growth of a single morphological type in culture. Two-hundred twenty of them showed bacterial growth of >10 5 CFU/ml. Microorganism identifications in this group were coincident at the species level in 202 cases (91.8%) and at the genus level in 204 cases (92.7%). The most frequent microorganism was Escherichia coli (173 isolates). MALDI-TOF MS identified this microorganism directly from the urine sample in 163 cases (94.2%). Our results show that MALDI-TOF MS allows bacterial identification directly from infected urine in a short time, with high accuracy, and especially when Gram-negative bacteria with high bacterial counts are involved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02215-09

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 341

Metadata

Authors
Ferreira, L., Sánchez-Juanes, F., González-Ávila, M., Cembrero-Fuciños, D., Herrero-Hernández, A., González-Buitrago, J. M., & Muñoz-Bellido, J. L.
Venue
Journal of Clinical Microbiology
Published
2010-06
Volume
48
Issue
6
Pages
2110-2115
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2100073472
Cited by
341
References
13
FWCI
17.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry. https://app.cochat.ai/papers/10.1128/jcm.02215-09
The paper
Ferreira, L., Sánchez-Juanes, F., González-Ávila, M., Cembrero-Fuciños, D., Herrero-Hernández, A., González-Buitrago, J. M., & Muñoz-Bellido, J. L. (2010). Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.02215-09

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.