Operational Feasibility of Using Loop-Mediated Isothermal Amplification for Diagnosis of Pulmonary Tuberculosis in Microscopy Centers of Developing Countries
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The characteristics of loop-mediated isothermal amplification (LAMP) make it a promising platform for the molecular detection of tuberculosis (TB) in developing countries. Here, we report on the first clinical evaluation of LAMP for the detection of pulmonary TB in microscopy centers in Peru, Bangladesh, and Tanzania to determine its operational applicability in such settings. A prototype LAMP assay with simplified manual DNA extraction was evaluated for accuracy and ease of use. The sensitivity of LAMP in smear- and culture-positive sputum specimens was 97.7% (173/177 specimens; 95% confidence interval [CI], 95.5 to 99.9%), and the sensitivity in smear-negative, culture-positive specimens was 48.8% (21/43 specimens; CI, 33.9 to 63.7%). The specificity in culture-negative samples was 99% (500/505 specimens; CI, 98.1 to 99.9%). The average hands-on time for testing six samples and two controls was 54 min, similar to that of sputum smear microscopy. The optimal amplification time was 40 min. No indeterminate results were reported, and the interreader variability was 0.4%. Despite the use of a single room without biosafety cabinets for all procedures, no DNA contamination was observed. The assay was robust, with high end-point stability and low rates of test failure. Technicians with no prior molecular experience easily performed the assay after 1 week of training, and opportunities for further simplification of the assay were identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Self-citationAccelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Self-citationIwamoto, T., Sonobe, T., & Hayashi, K. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.6.2616-2622.2003 · Cited by 612
Dye, C. (2005) · JAMA · doi:10.1001/jama.293.22.2767 · Cited by 534
Poon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Parida, M., Posadas, G., Inoue, S., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.1.257-263.2004 · Cited by 438
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 422
Self-citationParida, M., Horioke, K., Ishida, H., Dash, P. K., Saxena, P., Jana, A. M., Islam, M. A., Inoue, S., Hosaka, N., & Morita, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.6.2895-2903.2005 · Cited by 358
Loop-Mediated Isothermal Amplification for Detection of African Trypanosomes
Kuboki, N., Inoue, N., Sakurai, T., Di Cello, F., Grab, D. J., Suzuki, H., Sugimoto, C., & Igarashi, I. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.12.5517-5524.2003 · Cited by 352
Advances in the Diagnosis and Treatment of Tuberculosis
Nahid, P., Pai, M., & Hopewell, P. C. (2006) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200511-119jh · Cited by 208
Pai, M., Kalantri, S., & Dheda, K. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.3.423 · Cited by 193
Assessment by Meta-Analysis of PCR for Diagnosis of Smear-Negative Pulmonary Tuberculosis
Sarmiento, O. L., Weigle, K. A., Alexander, J., Weber, D. J., & Miller, W. C. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.7.3233-3240.2003 · Cited by 190
Noordhoek, G. T., van Embden, J. D., & Kolk, A. H. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.10.2522-2525.1996 · Cited by 172
Piersimoni, C., & Scarparo, C. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.12.5355-5365.2003 · Cited by 159
New tools for the diagnosis of tuberculosis: the perspective of developing countries.
Foulds, J., & O'Brien, R. (1998) · PubMed · Cited by 150
Bergmann, J. S., & Woods, G. L. (1996) · Journal of Clinical Microbiology · doi:10.1128/jcm.34.5.1083-1085.1996 · Cited by 97
New diagnostic tools for tuberculosis.
Perkins, M. D. (2000) · PubMed · Cited by 89
Self-citationEvaluation of the polymerase chain reaction for the detection of Mycobacterium tuberculosis.
Suffys, P. N., Palomino, J. C., Leão, S. C., Espitia, C., Cataldi, A. A., Alito, A., Velasco, M., Robledo, J., Fernández, J. O., Rosa, P. D. S., et al. (2000) · PubMed · Cited by 38
Cited by
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
Steingart, K. R., Schiller, I., Horne, D. J., Pai, M., Boehme, C. C., & Dendukuri, N. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009593.pub3 · Cited by 1,102
Self-citationMori, Y., & Notomi, T. (2009) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-009-0669-9 · Cited by 1,015
Self-citationLoop-mediated isothermal amplification (LAMP): principle, features, and future prospects
Notomi, T., Mori, Y., Tomita, N., & Kanda, H. (2015) · Journal of Microbiology · doi:10.1007/s12275-015-4656-9 · Cited by 889
Self-citationPoint-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838
Lawn, S. D., & Zumla, A. I. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62173-3 · Cited by 751
Metadata
- Authors
- Boehme, C. C., Nabeta, P., Henostroza, G., Raqib, R., Rahim, Z., Gerhardt, M., Sanga, E., Hoelscher, M., Notomi, T., Hase, T., & Perkins, M. D.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2007-06
- Volume
- 45
- Issue
- 6
- Pages
- 1936-1940
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2162859059
- Cited by
- 341
- References
- 18
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.