The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus
Open accessAbstract
Quantitative real-time PCR (QRT-PCR) has been widely implemented for clinical viral load testing, but a lack of standardization and relatively poor precision have hindered its usefulness. Digital PCR offers highly precise, direct quantification without requiring a calibration curve. Performance characteristics of real-time PCR were compared to those of droplet digital PCR (ddPCR) for cytomegalovirus (CMV) load testing. Tenfold serial dilutions of the World Health Organization (WHO) and the National Institute of Standards and Technology (NIST) CMV quantitative standards were tested, together with the AcroMetrix CMV tc panel (Life Technologies, Carlsbad, CA) and 50 human plasma specimens. Each method was evaluated using all three standards for quantitative linearity, lower limit of detection (LOD), and accuracy. Quantitative correlation, mean viral load, and variability were compared. Real-time PCR showed somewhat higher sensitivity than ddPCR (LODs, 3 log 10 versus 4 log 10 copies/ml and IU/ml for NIST and WHO standards, respectively). Both methods showed a high degree of linearity and quantitative correlation for standards ( R 2 ≥ 0.98 in each of 6 regression models) and clinical samples ( R 2 = 0.93) across their detectable ranges. For higher concentrations, ddPCR showed less variability than QRT-PCR for the WHO standards and AcroMetrix standards ( P < 0.05). QRT-PCR showed less variability and greater sensitivity than did ddPCR in clinical samples. Both digital and real-time PCR provide accurate CMV load data over a wide linear dynamic range. Digital PCR may provide an opportunity to reduce the quantitative variability currently seen using real-time PCR, but methods need to be further optimized to match the sensitivity of real-time PCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Properties of sufficiency and statistical tests
Bartlett, M. S. (1937) · Proceedings of the Royal Society of London. Series A - Mathematical and Physical Sciences · doi:10.1098/rspa.1937.0109 · Cited by 2,415
Properties of Sufficiency and Statistical Tests
Bartlett, M. S. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-0919-5_8 · Cited by 1,886
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Whale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453
Cytomegalovirus in Hematopoietic Stem Cell Transplant Recipients
Ljungman, P., Hakki, M., & Boeckh, M. (2011) · Hematology/Oncology Clinics of North America · doi:10.1016/j.hoc.2010.11.011 · Cited by 423
Evaluation of digital PCR for absolute DNA quantification
Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A. (2011) · Analytical Chemistry · doi:10.1021/ac103230c · Cited by 338
High-Throughput Quantitative Polymerase Chain Reaction in Picoliter Droplets
Kiss, M. M., Ortoleva-Donnelly, L., Beer, N. R., Warner, J., Bailey, C. G., Colston, B. W., Rothberg, J. M., Link, D. R., & Leamon, J. H. (2008) · Analytical Chemistry · doi:10.1021/ac801276c · Cited by 326
Shen, F., Sun, B., Kreutz, J. E., Davydova, E. K., Du, W., Reddy, P. L., Joseph, L. J., & Ismagilov, R. F. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2060116 · Cited by 231
Cited by
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Clonal evolution and resistance to EGFR blockade in the blood of colorectal cancer patients
Siravegna, G., Mussolin, B., Buscarino, M., Corti, G., Cassingena, A., Crisafulli, G., Ponzetti, A., Cremolini, C., Amatu, A., Lauricella, C., et al. (2015) · Nature Medicine · doi:10.1038/nm.3870 · Cited by 1,082
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Considerations for Digital PCR as an Accurate Molecular Diagnostic Tool
Huggett, J. F., Cowen, S., & Foy, C. A. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.221366 · Cited by 444
Use of Droplet Digital PCR for Estimation of Fish Abundance and Biomass in Environmental DNA Surveys
Doi, H., Uchii, K., Takahara, T., Matsuhashi, S., Yamanaka, H., & Minamoto, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0122763 · Cited by 319
Acquired Resistance to the TRK Inhibitor Entrectinib in Colorectal Cancer
Russo, M., Misale, S., Wei, G., Siravegna, G., Crisafulli, G., Lazzari, L., Corti, G., Rospo, G., Novara, L., Mussolin, B., et al. (2016) · Cancer Discovery · doi:10.1158/2159-8290.cd-15-0940 · Cited by 308
Digital Assays Part I: Partitioning Statistics and Digital PCR
Basu, A. S. (2017) · SLAS Technology · doi:10.1177/2472630317705680 · Cited by 300
Devonshire, A. S., Whale, A. S., Gutteridge, A., Jones, G., Cowen, S., Foy, C. A., & Huggett, J. F. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7835-3 · Cited by 299
Droplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
Applications of Digital PCR for Clinical Microbiology
Kuypers, J., & Jerome, K. R. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00211-17 · Cited by 280
Rački, N., Dreo, T., Gutierrez-Aguirre, I., Blejec, A., & Ravnikar, M. (2014) · Plant Methods · doi:10.1186/s13007-014-0042-6 · Cited by 257
Taylor, S. C., Carbonneau, J., Shelton, D. N., & Boivin, G. (2015) · Journal of Virological Methods · doi:10.1016/j.jviromet.2015.08.014 · Cited by 142
Boivin, V., Deschamps-Francoeur, G., Couture, S., Nottingham, R. M., Bouchard-Bourelle, P., Lambowitz, A. M., Scott, M. S., & Abou-Elela, S. (2018) · RNA · doi:10.1261/rna.064493.117 · Cited by 95
Yurick, D., Khoury, G., Clemens, B., Loh, L., Pham, H., Kedzierska, K., Einsiedel, L., & Purcell, D. (2019) · Journal of Clinical Microbiology · doi:10.1128/jcm.01063-18 · Cited by 23
Metadata
- Authors
- Hayden, R. T., Gu, Z., Ingersoll, J., Abdul-Ali, D., Shi, L., Pounds, S., & Caliendo, A. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2013-02
- Volume
- 51
- Issue
- 2
- Pages
- 540-546
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2168327674
- Cited by
- 335
- References
- 26
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.