Factors contributing to an increase in duplicate medication order errors after CPOE implementation
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the incidence of duplicate medication orders before and after computerized provider order entry (CPOE) with clinical decision support (CDS) implementation and identify contributing factors. DESIGN: CPOE with duplicate medication order alerts was implemented in a 400-bed Northeastern US community tertiary care teaching hospital. In a pre-implementation post-implementation design, trained nurses used chart review, computer-generated reports of medication orders, provider alerts, and staff reports to identify medication errors in two intensive care units (ICUs). MEASUREMENT: Medication error data were adjudicated by a physician and a human factors engineer for error stage and type. A qualitative analysis of duplicate medication ordering errors was performed to identify contributing factors. RESULTS: Data were collected for 4147 patient-days pre-implementation and 4013 patient-days post-implementation. Duplicate medication ordering errors increased after CPOE implementation (pre: 48 errors, 2.6% total; post: 167 errors, 8.1% total; p<0.0001). Most post-implementation duplicate orders were either for the identical order or the same medication. Contributing factors included: (1) provider ordering practices and computer availability, for example, two orders placed within minutes by different providers on rounds; (2) communication and hand-offs, for example, duplicate orders around shift change; (3) CDS and medication database design, for example confusing alert content, high false-positive alert rate, and CDS algorithms missing true duplicates; (4) CPOE data display, for example, difficulty reviewing existing orders; and (5) local CDS design, for example, medications in order sets defaulted as ordered. CONCLUSIONS: Duplicate medication order errors increased with CPOE and CDS implementation. Many work system factors, including the CPOE, CDS, and medication database design, contributed to their occurrence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Work system design for patient safety: the SEIPS model
Carayon, P., Schoofs Hundt, A., Karsh, B.-T., Gurses, A. P., Alvarado, C. J., Smith, M., & Flatley Brennan, P. (2006) · Quality in Health Care · doi:10.1136/qshc.2005.015842 · Cited by 1,795
Self-citationThe Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260 · cited 2×
“0001 Same medication 13 (27%) 75 (45%) Same therapeutic class 20 (42%) 23 (14%) Most frequently duplicated medication classes by rank order (number) 1 Gastrointestinal (9) Electrolytes (30) 2 Electrolytes (8) Gastrointestinal (23) 3 Narcotics, analgesics (6) Cardiac (21) 4 Antibiotics (6) Crystalloids, colloids, paren…”
BackgroundOverriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763 · cited 5×
“The solutions conform to the principles of designing systems to (1) support communication and collaboration among the healthcare team, (2) enhance error recovery by improving team and individual situation awareness, particularly around shift changes and other hand-offs, (3) improve teamwork with regards to order entry…”
BackgroundMethodInfluentialDesigning for Situation Awareness
Endsley, M. R., Bolte, B., & Jones, D. G. (2003) · doi:10.1201/9780203485088 · Cited by 675
A balance theory of job design for stress reduction
Smith, M. J., & Sainfort, P. C. (1989) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(89)90051-6 · Cited by 488
Phansalkar, S., Edworthy, J., Hellier, E., Seger, D. L., Schedlbauer, A., Avery, A. J., & Bates, D. W. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005264 · Cited by 226 · cited 2×
“0001 Same medication 13 (27%) 75 (45%) Same therapeutic class 20 (42%) 23 (14%) Most frequently duplicated medication classes by rank order (number) 1 Gastrointestinal (9) Electrolytes (30) 2 Electrolytes (8) Gastrointestinal (23) 3 Narcotics, analgesics (6) Cardiac (21) 4 Antibiotics (6) Crystalloids, colloids, paren…”
BackgroundUsing failure mode and effects analysis to plan implementation of smart i.v. pump technology
Wetterneck, T. B., Skibinski, K. A., Roberts, T. L., Kleppin, S. M., Schroeder, M. E., Enloe, M., Rough, S. S., Hundt, A. S., & Carayon, P. (2006) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp050515 · Cited by 134
Self-citationEHR Safety: The Way Forward to Safe and Effective Systems
Walker, J. M., Carayon, P., Leveson, N., Paulus, R. A., Tooker, J., Chin, H., Bothe, A., & Stewart, W. F. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2618 · Cited by 113
Self-citationLin, C.-P., Payne, T. H., Nichol, W. P., Hoey, P. J., Anderson, C. L., & Gennari, J. H. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2453 · Cited by 110
Cited by
Holden, R. J., Carayon, P., Gurses, A. P., Hoonakker, P., Hundt, A. S., Ozok, A. A., & Rivera-Rodriguez, A. J. (2013) · Ergonomics · doi:10.1080/00140139.2013.838643 · Cited by 1,221
“…al., 2013; Hoonakker, Carayon, Walker, Brown, & Cartmill, 2013; Hoonakker, Wetterneck, Carayon, Cartmill, & Walker, 2011; Hundt A.S. et al., 2013; Wetterneck et al., 2011) Health information technology-supported care management in community setting (Carayon, Alyousef, et al., 2012; Hundt et al.,…”
Self-citationHuman factors systems approach to healthcare quality and patient safety
Carayon, P., Wetterneck, T. B., Rivera-Rodriguez, A. J., Hundt, A. S., Hoonakker, P., Holden, R., & Gurses, A. P. (2014) · Applied Ergonomics · doi:10.1016/j.apergo.2013.04.023 · Cited by 717
Self-citationHorsky, J., Schiff, G. D., Johnston, D., Mercincavage, L., Bell, D., & Middleton, B. (2012) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.09.002 · Cited by 289
Kim, M. O., Coiera, E., & Magrabi, F. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw154 · Cited by 263
Electronic health records and national patient-safety goals
Sittig, D. F., & Singh, H. (2012) · New England Journal of Medicine · doi:10.1056/nejmsb1205420 · Cited by 204
Metadata
- Authors
- Wetterneck, T. B., Walker, J. M., Blosky, M. A., Cartmill, R. S., Hoonakker, P., Johnson, M. A., Norfolk, E., & Carayon, P.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11
- Volume
- 18
- Issue
- 6
- Pages
- 774-782
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2128084015
- Cited by
- 108
- References
- 10
- FWCI
- 19.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors contributing to an increase in duplicate medication order errors after CPOE implementation. https://app.cochat.ai/papers/10.1136/amiajnl-2011-000255
- The paper
- Wetterneck, T. B., Walker, J. M., Blosky, M. A., Cartmill, R. S., Hoonakker, P., Johnson, M. A., Norfolk, E., & Carayon, P. (2011). Factors contributing to an increase in duplicate medication order errors after CPOE implementation. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2011-000255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.