CoChat

Understanding and preventing wrong-patient electronic orders: a randomized controlled trial

Open access
Adelman, Jason S, Kalkut, Gary E, Schechter, Clyde B, Weiss, Jeffrey M, Berger, Matthew A, Reissman, Stan H, Cohen, Hillel W, Lorenzen, Stephen J, Burack, Daniel A, Southern, William N · 2013 · Journal of the American Medical Informatics Association
Cited by 134

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To evaluate systems for estimating and preventing wrong-patient electronic orders in computerized physician order entry systems with a two-phase study. MATERIALS AND METHODS: In phase 1, from May to August 2010, the effectiveness of a 'retract-and-reorder' measurement tool was assessed that identified orders placed on a patient, promptly retracted, and then reordered by the same provider on a different patient as a marker for wrong-patient electronic orders. This tool was then used to estimate the frequency of wrong-patient electronic orders in four hospitals in 2009. In phase 2, from December 2010 to June 2011, a three-armed randomized controlled trial was conducted to evaluate the efficacy of two distinct interventions aimed at preventing these errors by reverifying patient identification: an 'ID-verify alert', and an 'ID-reentry function'. RESULTS: The retract-and-reorder measurement tool effectively identified 170 of 223 events as wrong-patient electronic orders, resulting in a positive predictive value of 76.2% (95% CI 70.6% to 81.9%). Using this tool it was estimated that 5246 electronic orders were placed on wrong patients in 2009. In phase 2, 901 776 ordering sessions among 4028 providers were examined. Compared with control, the ID-verify alert reduced the odds of a retract-and-reorder event (OR 0.84, 95% CI 0.72 to 0.98), but the ID-reentry function reduced the odds by a larger magnitude (OR 0.60, 95% CI 0.50 to 0.71). DISCUSSION AND CONCLUSION: Wrong-patient electronic orders occur frequently with computerized provider order entry systems, and electronic interventions can reduce the risk of these errors occurring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2012-001055

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 134

Metadata

Authors
Adelman, J. S., Kalkut, G. E., Schechter, C. B., Weiss, J. M., Berger, M. A., Reissman, S. H., Cohen, H. W., Lorenzen, S. J., Burack, D. A., & Southern, W. N.
Venue
Journal of the American Medical Informatics Association
Published
2013-03
Volume
20
Issue
2
Pages
305-310
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2157459668
Cited by
134
References
9
FWCI
10.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.