The DOI matches its Crossref record; 35 of the 38 references it cites were found in a registry or an index.
Measuring and improving patient safety through health information technology: The Health IT Safety Framework
Open accessAbstract
Health information technology (health IT) has potential to improve patient safety but its implementation and use has led to unintended consequences and new safety concerns. A key challenge to improving safety in health IT-enabled healthcare systems is to develop valid, feasible strategies to measure safety concerns at the intersection of health IT and patient safety. In response to the fundamental conceptual and methodological gaps related to both defining and measuring health IT-related patient safety, we propose a new framework, the Health IT Safety (HITS) measurement framework, to provide a conceptual foundation for health IT-related patient safety measurement, monitoring, and improvement. The HITS framework follows both Continuous Quality Improvement (CQI) and sociotechnical approaches and calls for new measures and measurement activities to address safety concerns in three related domains: 1) concerns that are unique and specific to technology (e.g., to address unsafe health IT related to unavailable or malfunctioning hardware or software); 2) concerns created by the failure to use health IT appropriately or by misuse of health IT (e.g. to reduce nuisance alerts in the electronic health record (EHR)), and 3) the use of health IT to monitor risks, health care processes and outcomes and identify potential safety concerns before they can harm patients (e.g. use EHR-based algorithms to identify patients at risk for medication errors or care delays). The framework proposes to integrate both retrospective and prospective measurement of HIT safety with an organization's existing clinical risk management and safety programs. It aims to facilitate organizational learning, comprehensive 360 degree assessment of HIT safety that includes vendor involvement, refinement of measurement tools and strategies, and shared responsibility to identify problems and implement solutions. A long term framework goal is to enable rigorous measurement that helps achieve the safety benefits of health IT in real-world clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These frameworks emphasise governance, monitoring, and continuous learning as essential complements to technical controls and user training (48, 55).”
From Why digital health fails silently: a sociotechnical theory of health information technology–related risk (2026) · cites this paper as [55]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Recent guidance on digital safety governance, including updates to the SAFER Guides, reflects growing recognition of the need for shared responsibility and organisational accountability in managing EHR-related risks.”
From Why digital health fails silently: a sociotechnical theory of health information technology–related risk (2026) · cites this paper as [55]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“National and international guidance increasingly reflects this shift, emphasising learning systems rather than static certification as the foundation for digital safety (1, 55, 59, 62).”
From Why digital health fails silently: a sociotechnical theory of health information technology–related risk (2026) · cites this paper as [55]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Rather than focusing primarily on preventing individual errors, the findings suggest that safer digital healthcare depends on strengthening organisational capacity to detect emerging hazards, contain their effects, and learn from system-level vulnerabilities (28, 55).”
From Why digital health fails silently: a sociotechnical theory of health information technology–related risk (2026) · cites this paper as [55]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human error: models and management
Reason, J. (2000) · BMJ · doi:10.1136/bmj.320.7237.768 · Cited by 5,665
Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
To Err is Human: Building a Safer Health System in 1999.
Stefl, M. E. (2001) · PubMed · Cited by 1,738
Sittig, D. F., & Singh, H. (2010) · Quality and Safety in Health Care · doi:10.1136/qshc.2010.042085 · Cited by 897
Self-citationAssociation of Interruptions With an Increased Risk and Severity of Medication Administration Errors
Westbrook, J. I. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.65 · Cited by 766
Measuring errors and adverse events in health care
Thomas, E. J., & Petersen, L. A. (2003) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2003.20147.x · Cited by 455
Vincent, C., Burnett, S., & Carthey, J. (2014) · BMJ Quality & Safety · doi:10.1136/bmjqs-2013-002757 · Cited by 217
An analysis of electronic health record-related patient safety concerns
Meeks, D. W., Smith, M. W., Taylor, L., Sittig, D. F., Scott, J. M., & Singh, H. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-002578 · Cited by 207
Self-citationElectronic health records and national patient-safety goals
Sittig, D. F., & Singh, H. (2012) · New England Journal of Medicine · doi:10.1056/nejmsb1205420 · Cited by 204
Self-citationAdvancing the science of measurement of diagnostic errors in healthcare: the Safer Dx framework
Singh, H., & Sittig, D. F. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2014-003675 · Cited by 195
Self-citation
Research works printed but not linked: 2
- Weick, 1999, Organizing for high reliability: Processes of collective mindfulness, Res Organ Behav, 21, 81
- Ruder, 2014, Malpractice claims analysis confirms risks in EHRs, Patient Saf Qual Healthc, 11, 20
Cited by
Kim, M. O., Coiera, E., & Magrabi, F. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw154 · Cited by 263
Current challenges in health information technology–related patient safety
Sittig, D. F., Wright, A., Coiera, E., Magrabi, F., Ratwani, R., Bates, D. W., & Singh, H. (2020) · Health Informatics Journal · doi:10.1177/1460458218814893 · Cited by 171
Self-citationA Socio-technical Approach to Preventing, Mitigating, and Recovering from Ransomware Attacks
Singh, H., & Sittig, D. F. (2016) · Applied Clinical Informatics · doi:10.4338/aci-2016-04-soa-0064 · Cited by 152
Self-citationSittig, D. F., Belmont, E., & Singh, H. (2017) · Healthcare · doi:10.1016/j.hjdsi.2017.06.004 · Cited by 115
“33 Assigning responsibility to address safety concerns to only the developer responsible for some but not all issues, or only to the health system that has no control over how the system was designed and built, will not be successful because overall safety is based on their combined actions.”
BackgroundSelf-citationPreckel, B., Staender, S. E. A., Velasco, D. A., Brattebø, G., Feldman, J. M., ffrench‐O'Carroll, R., Fuchs‐Buder, T., Goldhaber-Fiebert, S. N., Haller, G., Haugen, A. S., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001244 · Cited by 89
“They are based on electronic tracking, and examples include recognition of nosocomial infections, hazards associated with drugs or wrong patient orders and medical device dysfunctions.(141) To detect errors and complications, methods based on computing technologies use electronic algorithms to analyse hospital adminis…”
Method
Metadata
- Authors
- Singh, H., & Sittig, D. F.
- Affiliations
- Michael E. DeBakey VA Medical Center (US)
- Memorial Hermann (US)
- Corresponding author
- Singh, Hardeep
- Venue
- BMJ Quality & Safety
- Publisher
- BMJ
- Published
- 2015-09-14
- Volume
- 25
- Issue
- 4
- Pages
- 226-232
- ISSN
- 1475-3898 (ISSN-L)
- 2044-5415
- 2044-5423
- PMC
- PMC4819641
- OpenAlex
- W2175323185
- Cited by
- 167
- References
- 38
- Citations by year
- 2026: 18 · 2025: 9 · 2024: 17 · 2023: 12 · 2022: 20 · 2021: 16 · 2020: 13 · 2019: 20 · 2018: 8 · 2017: 17 · 2016: 14 · 2015: 2
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- BMJ Quality & Safety (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- Health Services Research and Development (CIN 13‐413, CRE12-033, USA 14-274)
- Agency for Healthcare Research and Quality (R01HS022087)
- Center for Innovations in Quality, Effectiveness and Safety (CIN 13–413, 13–413)
- VA National Center for Patient Safety
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- health information technology, patient safety, safety measurement, electronic health records, clinical decision support alerts, medication errors, continuous quality improvement, socio-technical approach, clinical risk management, organizational learning
- MeSH terms
- Humans, Medical Informatics, United States, Information Dissemination, Electronic Health Records, Quality Improvement, Patient Safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring and improving patient safety through health information technology: The Health IT Safety Framework. https://app.cochat.ai/papers/10.1136/bmjqs-2015-004486
- The paper
- Singh, H., & Sittig, D. F. (2016). Measuring and improving patient safety through health information technology: The Health IT Safety Framework. BMJ Quality & Safety. https://doi.org/10.1136/bmjqs-2015-004486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.