Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). METHODS: Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. RESULTS: The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). CONCLUSIONS: DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhu, Y., Pandya, B. J., & Choi, H. K. (2011) · Arthritis & Rheumatism · doi:10.1002/art.30520 · Cited by 1,785
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Preliminary criteria for the classification of the acute arthritis of primary gout
Wallace, S. L., Robinson, H., Masi, A. T., Decker, J. L., Mccarty, D. J., & Yü, T. (1977) · Arthritis & Rheumatism · doi:10.1002/art.1780200320 · Cited by 1,432
Zhang, W., Doherty, M., Bardin, T., Pascual, E., Barskova, V, Conaghan, P., Gerster, J., Jacobs, J., Leeb, B., Lioté, F., et al. (2006) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2006.055269 · Cited by 1,407
Zhang, W., Doherty, M., Pascual, E., Bardin, T., Barskova, V, Conaghan, P., Gerster, J., Jacobs, J., Leeb, B., Lioté, F., et al. (2006) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2006.055251 · Cited by 584
Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Dual energy computed tomography in tophaceous gout
Choi, H. K., Al-Arfaj, A. M., Eftekhari, A., Munk, P. L., Shojania, K., Reid, G., & Nicolaou, S. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2008.099713 · Cited by 330
The value of synovial fluid assays in the diagnosis of joint disease: a literature survey
Swan, A., Amer, H., & Dieppe, P. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.6.493 · Cited by 317
Uric acid is a danger signal of increasing risk for osteoarthritis through inflammasome activation
Denoble, A. E., Huffman, K. M., Stabler, T. V., Kelly, S. J., Hershfield, M. S., McDaniel, G. E., Coleman, R. E., & Kraus, V. B. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012743108 · Cited by 266
Glazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H. (2011) · Radiology · doi:10.1148/radiol.11102485 · Cited by 242
Self-citationDual energy CT in gout: a prospective validation study
Choi, H. K., Burns, L. C., Shojania, K., Koenig, N., Reid, G., Abufayyah, M., Law, G., Kydd, A. S., Ouellette, H., & Nicolaou, S. (2012) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2011-200976 · Cited by 197
Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout
Desai, M. A., Peterson, J. J., Garner, H. W., & Kransdorf, M. J. (2011) · RadioGraphics · doi:10.1148/rg.315115510 · Cited by 173
Dual-energy computed tomography compared with ultrasound in the diagnosis of gout
Gruber, M. S., Bodner, G., Rath, E., Supp, G. M., Weber, M., & Schueller-Weidekamm, C. (2013) · Rheumatology · doi:10.1093/rheumatology/ket341 · Cited by 85
How is Gout Managed in Primary Care? A Review of Current Practice and Proposed Guidelines
Pal, B., Foxall, M., Dysart, T., Carey, F., & Whittaker, M. (2000) · Clinical Rheumatology · doi:10.1007/s100670050005 · Cited by 74
The Role of Uric Acid and Other Crystals in Osteoarthritis
Nowatzky, J., Howard, R. G., Pillinger, M. H., & Krasnokutsky, S. (2010) · Current Rheumatology Reports · doi:10.1007/s11926-010-0091-4 · Cited by 36
Cited by
Gout: An old disease in new perspective – A review
Ragab, G., Elshahaly, M., & Bardin, T. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.04.008 · Cited by 599
Richette, P., Doherty, M., Pascual, E., Barskova, V., Becce, F., Castaneda, J., Coyfish, M., Guillo, S., Jansen, T., Janssens, H., et al. (2020) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2019-215315 · Cited by 440
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Gout: state of the art after a decade of developments
Pascart, T., & Lioté, F. (2018) · Rheumatology · doi:10.1093/rheumatology/key002 · Cited by 173
Imaging modalities for the classification of gout: systematic literature review and meta-analysis
Ogdie, A., Taylor, W. J., Weatherall, M., Fransen, J., Jansen, T. L., Neogi, T., Schumacher, H. R., & Dalbeth, N. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2014-205431 · Cited by 169
Metadata
- Authors
- Bongartz, T., Glazebrook, K. N., Kavros, S. J., Murthy, N. S., Merry, S. P., Franz, W. B., Michet, C. J., Veetil, B. M. A., Davis, J. M., Mason, T. G., Warrington, K. J., Ytterberg, S. R., Matteson, E. L., Crowson, C. S., Leng, S., & McCollough, C. H.
- Venue
- Annals of the Rheumatic Diseases
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 74
- Issue
- 6
- Pages
- 1072-1077
- ISSN
- 0003-4967 (ISSN-L)
- OpenAlex
- W2008245966
- Cited by
- 276
- References
- 15
- FWCI
- 16.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.